Warranty • Product Specifications
11
For parts or assistance, call Jung Pumpen Customer Service at 1-800-642-5930
Limited Warranty
Jung Pumpen warrants to the original consumer purchaser (“Purchaser” or “You”) of Jung Pumpen Effluent Pumps, Sewage Pumps, and Package
Systems, that they will be free from defects in material and workmanship for the Warranty Period of 12 months from date of manufacture.
Our warranty will not apply to any product that, in our sole judgement, has been subject to negligence, misapplication, improper installation, or
improper maintenance. Without limiting the foregoing, operating a three phase motor with single phase power through a phase converter will void the
warranty. Note also that three phase motors must be protected by three-leg, ambient compensated, extra-quick trip overload relays of the recommended
size or the warranty is void.
Your only remedy, and Jung Pumpen’s only duty, is that Jung Pumpen repair or replace defective products (at Jung Pumpen’s choice). You must pay all
labor and shipping charges associated with this warranty and must request warranty service through the installing dealer or selling distributor as soon
as a problem is discovered. No request for service will be accepted if received after the Warranty Period has expired. This warranty is not transferable.
EXCEPTIONS: Special Application Pumps, Filtered Effluent Pumps, Grinder Pumps, 2-1/2” Sewage Pumps, and Lift Systems are warranted for a period
of 12 months from date of purchase or 18 months from date of manufacture, whichever comes first.
Jung Pumpen SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT DAMAGES WHATSOEVER.
THE FOREGOING LIMITED WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS AND IMPLIED WARRANTIES, INCLUDING BUT
NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. THE FOREGOING WARRANTIES
SHALL NOT EXTEND BEYOND THE DURATION EXPRESSLY PROVIDED HEREIN.
Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on the duration of an implied warranty, so the
above limitations or exclusions may not apply to You. This warranty gives You specific legal rights and You may also have other rights which vary from
state to state.
This limited warranty supersedes and replaces all previous warranty publications.
Jung Pumpen
293 Wright Street, Delavan, WI 53115
Phone: 800-642-5930 • jungpumpen-us.com
Model
HP
PHASE
Frequency
Voltage*
F.L.C.
R.P.M.
Max. head
Max. flow rate
Weight
†
Cable SOOW
START PAK
Hz
Volts
Amp
1/min
ft
m
GPM
LPM
lbs
kg
V1d-01
1
1
60
200
9
1680
16
5
264
999
108
49
12/6 AWG 12
SPGV-7
V1d-03
3
1685
not required
V1d-21
1
230
8
1680
SPGV-8
V1d-23
3
6.2
1685
not required
V1d-43
460
3.5
V15d-01
1.5
1
200
13.3
1675
23
7
352
1332
SPGV-9
V15d-03
3
9.7
not required
V15d-21
1
230
11.6
SPGV-10
V15d-23
3
7.4
not required
V15d-43
460
4
V2d-01
2
1
200
17.2
1650
31
9
396
1499
SPGV-11
V2d-03
3
10.7
1620
not required
V2d-21
1
230
15.5
1675
SPGV-12
V2d-23
3
8.7
1620
not required
V2d-43
460
4.6
V3d-01
3
1
200
20.5
1720
36
11
484
1832
117
53
10/6 AWG 10
SPGV-13
V3d-03
3
13.6
1670
39
12
12/6 AWG 12
not required
V3d-21
1
230
18.5
1720
36
11
10/6 AWG 10
SPGV-14
V3d-23
3
12.5
1670
39
12
12/6 AWG 12
not required
V3d-43
460
7
V5d-43
‡
5
10.2
1680
44
13
660
2498
249
113
V7d-43
‡
7.5
12.3
1670
52
16
748
2831
258
117
* Input voltage ±10%
† Weight with 25 ft (7.6 m) cable. add 7 lb (3.2 kg) for each additional 25 ft (7.6 m).
‡ oil chamber capacity is 61 in
3
(1000 cc) except for V5d and V7d, which is 103.7 in
3
(1700 cc)