Troubleshooting 

10

 Hazardous voltage. 

Can shock, burn, or 

kill. disconnect power before attempting any service or 
repair work on pump.

 

Hazardous impellers and unexpected starts 

which can cause loss of fingers.

 Keep hands away from 

pump suction inlet when working on or servicing pump.

Symptom

Possible Cause(s)

Corrective Action

Motor not running

Motor protector tripped.

Allow motor to cool. Make sure pump is completely submerged. Clear debris from volute 

and impeller. Check for high amp draw.

open circuit breaker or blown fuse.

replace fuse or reset breaker. If circuit breaker opens repeatedly, don’t reset it - call a 

licensed electrician.

Impeller clogged or binding.

Check amp draw. If it is more than twice the nameplate amps, the impeller is locked. 

Bearings and shaft may be damaged. DISCONNECT POWER, clear debris from volute, 

impeller, and cutter as needed.

power cable damaged.

resistance between power cable and ground should be infinity. If any reading is less than 

infinity, call a licensed electrician.

Bad control panel.

Inspect control panel wiring. Call a licensed electrician.

defective liquid level switch.

With switch disconnected from power, check continuity through switch while activating 

liquid level switch. replace switch if necessary.

not enough liquid in wet well to activate 

controls.

allow the liquid to rise several inches above the switch-on level.

liquid level cords tangled

untangle cords for free operation.

automatic controls defective

try running pump in manual mode. If it runs, the automatic control is at fault.

pump runs continuously

liquid level control cords tangled

untangle cords for free operation.

pump is airlocked.

stop pump for about one minute, then restart. repeat stopping and starting until the 

airlock clears. If the airlock persists, DISCONNECT POWER, pull the pump and drill a 
1/8” hole in the discharge pipe between the pump discharge and the check valve.

Flow in matches or exceeds the pump’s 

capacity.

a larger pump or more pumps may be needed.

little or no effluent 

delivered from pump

Check valve plugged, stuck shut, or 

installed backwards.

Make sure check valve is installed correctly (flow arrow should point away from pump) 

and functioning correctly.

system head excessive.

Consult dealer.

pump suction plugged.

DISCONNECT POWER, pull pump, inspect, and clear as needed.

Wrong voltage or not wired correctly.

Check pump’s rotation; check nameplate voltage against supply voltage (they must 

match); consult a licensed electrician.

pump is air locked.

stop pump for about one minute, then restart. repeat stopping and starting until the 

airlock clears. If the airlock persists, DISCONNECT POWER, pull the pump and drill a 
1/8” hole in the discharge pipe between the pump discharge and the check valve.

Worn or damaged impeller.

DISCONNECT POWER, pull pump and inspect impeller. Replace if necessary.

liquid level controls incorrectly installed 

or defective.

reposition or replace as necessary.

pump cycles constantly

no discharge check valve installed.

Install discharge check valve.

discharge check valve stuck open.

repair or replace check valve as necessary.

sewage wetwell too small.

Consult dealer.

liquid level controls incorrectly installed 

or defective.

reposition or replace as necessary.

pump too small for inlet flow.

Consult dealer about larger pump or second pump.

Summary of Contents for MULTIFREE V15D-01

Page 1: ...ing installation or maintenance assistance Call 1 800 642 5930 2011 JP912 1 21 11 Installation and Operator s Manual Submersible Solids Handling Pump 293 Wright St Delavan WI 53115 Phone 1 800 642 593...

Page 2: ...ing that exceeds the pump s capacity electrical or mechanical failure in the pump etc may prevent your pump from functioning normally To prevent possible damage consult your dealer about installing a...

Page 3: ...e If any is found file a claim with the carrier immediately Thank you for purchasing this Jung Pumpen product To help ensure years of trouble free operation please read the manual carefully This pump...

Page 4: ...and voids the warranty Make sure that the frequency and voltage shown on the nameplate corresponds to the frequency and voltage of the electrical supply The supply voltage must be within 10 of the nam...

Page 5: ...l load current Size the overload protective device so that the trip current is 115 of the nameplate full load current Operation Hazardous cutter and possible unexpected starts Rotation of the cutter w...

Page 6: ...ing chain not the cord and place the pump in a suitable area where it can be cleaned 4 Remove all scale and deposits from the pump Check visual appearance of all pump housing screws and mating surface...

Page 7: ...cavity 11 Use a flat blade screwdriver and very carefully pry the upper seal half from the bracket cavity Installing the New Shaft Seal NOTICE Install all new O Rings seals and gaskets during reassem...

Page 8: ...For parts or assistance call Jung Pumpen Customer Service at 1 800 642 5930 For parts or assistance call Jung Pumpen Customer Service at 1 800 642 5930 Repair Parts 8 1 2 8 3 7 4 3...

Page 9: ...JP43649 RP JP43654 RP JP43249 V15D 21 V15D 03 RP JP43644 RP JP21754 V15D 23 RP JP43910 V15D 43 RP JP43645 V2D 01 RP JP43649 RP JP43654 RP JP43092 V2D 21 V2D 03 RP JP43644 RP JP21754 V2D 23 RP JP43910...

Page 10: ...matic control is at fault Pump runs continuously Liquid level control cords tangled Untangle cords for free operation Pump is airlocked Stop pump for about one minute then restart Repeat stopping and...

Page 11: ...RANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS AND IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE THE FOREGOING...

Page 12: ...in V1D 01 385 5 15 18 247 9 72 138 6 5 46 277 10 91 75 2 95 440 5 17 34 V1D 21 V1D 03 V1D 23 V1D 43 V15D 01 475 5 18 72 V15D 21 V15D 03 440 5 17 34 V15D 23 V15D 43 V2D 01 475 5 18 72 V2D 21 V2D 03 44...

Reviews: