background image

4

Symbol

Description

IPX0

Degree of protection against the Ingress of water.

Warning

A personal injury or damage to the thermometer
may occur if the thermometer is not used correctly.

Attention

Inaccurate reading or damage to the thermometer
may occur if the thermometer is not used correctly.

Body Temperature Basics

You can take a body temperature on the forehead, in the ear canal, under
the armpit, in the mouth, or in the anus. The temperature measured at
different parts of the body may differ slightly.

Body Part

Normal Temperature Range

Forehead

36.1°C–37.5°C / 97.0°F–99.5°F

Ear canal

35.8°C–38.0°C /

96.44°F–100.40°F

Mouth

35.5°C–37.5°C / 95.9°F–99.5°F

Armpit

34.7°C–37.3°C / 94.46°F–99.14°F

Anus

36.6°C–38.0°C /

97.88°F–100.40°F

The normal body temperature range slightly varies with age and gender.
Generally, newborns or children have higher body temperature than adults,
and adults have higher body temperature than the elderly. Women's body
temperature are appropriately 0.3°C higher than men's.

Summary of Contents for JPD-FR203

Page 1: ...JPD FR203 Infrared Thermometer Instruction Manual Shenzhen Jumper Medical Equipment Co Ltd Manual Version 1 0 Date of Issue 2018 09 18 0482...

Page 2: ...out the prior consent of Shenzhen Jumper Medical Equipment Co Ltd All statements information and recommendations in this document are provided AS IS without warranties guarantees or representations of...

Page 3: ...7 Sounds and Backlight Instructions 8 Display and Operating Instructions 8 Measuring Forehead Temperature 15 Measuring Object Temperature 16 Replacing Batteries 17 Cleaning and Disinfection 18 Mainten...

Page 4: ...ss Package Contents No Name Quantity 1 Infrared Thermometer 1 2 Pouch 1 3 Battery AAA 2 4 Instruction Manual 1 Safety Precautions Read the following precautions carefully before using the thermometer...

Page 5: ...0 F which is beyond the operating temperature range of the thermometer Risk of pollution The user is recommended to send the overdue thermometer to local garbage disposal site or send it back to us 2...

Page 6: ...rous oxide is available Please keep the thermometer out of the reach of children The result may be inaccurate if you use the overdue thermometer Symbols Symbol Description Type BF applied part Attenti...

Page 7: ...pit in the mouth or in the anus The temperature measured at different parts of the body may differ slightly Body Part Normal Temperature Range Forehead 36 1 C 37 5 C 97 0 F 99 5 F Ear canal 35 8 C 38...

Page 8: ...frared energy emitted by the forehead After being focused by a lens the energy is converted into a temperature reading by the thermopiles and the measurement circuit 4 Intended use The Infrared Thermo...

Page 9: ...nsor with high sensitivity Enhanced accuracy with automatic temperature calibration 5 Diverse functions 20 temperature readings stored in memory Forehead Object temperature measurement Fever alert wit...

Page 10: ...de button Adult forehead temperature Child s forehead temperature Object temperature 6 Battery cover Display Description 1 Object temperature mode 2 Adult forehead temperature mode 3 Child s forehead...

Page 11: ...ight Indicates normal body temperature When the temperature is between 37 6 C 99 6 and 37 9 C 100 2 there will be a long beep and a orange backlight This indicates that the body temperature is slightl...

Page 12: ...een display Switch to adult or child measurement mode according to your measurement needs point the IR sensor to the center of the forehead Move the thermometer towards the forehead For effective meas...

Page 13: ...t temperature will be displayed on the screen See the table in the Sounds and Backlight Instructions section Out of the measuring range display In Object mode a temperature reading of more than 100 C...

Page 14: ...can switch units Silent Switching between forehead temperature and object temperature In a power on state press the Mode button to switch between adult forehead temperature child forehead temperature...

Page 15: ...tate Press the sound switch button to switch the sound on or off a long beep will be sounded when the sound is turned on and a mute symbol will be displayed when the sound is turned off A long beep wi...

Page 16: ...e When leave memory button LCD display 01 followed by the recorded reading Press the Memory button again for the next recorded data 02 will be shown followed by the recorded reading a maximum of 20 te...

Page 17: ...ack on a long beep the backlight is green then turn red Error information low battery The ambient temperature is higher than 40 0 C 104 0 F or lower than 10 0 C 50 0 F A long beep the backlight is red...

Page 18: ...easuring adults place the switching device in the adult mode When measuring children place the switching device in child mode and the symbol is displayed on the screen 4 Point the thermometer probe to...

Page 19: ...away from the object surface 4 Press and release the Measure button for 1 second The temperature reading will be displayed on the screen instantly 5 If no activity is detected the thermometer will po...

Page 20: ...it is sensitive to the ambient temperature 3 Make sure the sense head is free of foreign matters before use 4 Make sure the forehead has no sweat and no hairs covered before measure the forehead tempe...

Page 21: ...the local environmental policies The thermometer is shipped with batteries First open the battery cover then remove the insulating piece Cleaning and Disinfection Cleaning Recommended detergents Medi...

Page 22: ...sing hard objects do not immerse any part of the thermometer into liquid or allow liquid to penetrate the thermometer It is recommended to clean once a week each clean time within 3 minutes the repeat...

Page 23: ...y of 15 85 RH no condensation and the barometric pressure of 86kPa 106kPa Maintenance Preventive inspection maintenance period 1 Ensure the safety of thermometer and check whether it has potential saf...

Page 24: ...ayed The ambient temperature is lower than 10 C 50 0 F or higher than 40 C 104 F Take a measurement under an ambient temperature between 10 C 50 0 F and 40 C 104 F The temperature reading is lower tha...

Page 25: ...erating Display Segment LCD Measure time About 1 second Latency Time About 3second Measuring Distance 1 to 5 cm Measuring Range Forehead 35 0 42 2 95 0 108 0 Object 0 0 C 100 0 C 32 0 F 212 0 F Accura...

Page 26: ...ainst electric shock internally powered equipment Degree of protection against electric shock Type BF applied part Degree of protection against ingress of water IPX0 Safety degree of using in flammabl...

Page 27: ...gnetic emission The Infrared Thermometer JPD FR203 is intended for use in the electromagnetic environment specified below The customer or the user of the Infrared Thermometer JPD FR203 should assure t...

Page 28: ...ity should be at least 30 Power frequency 50 60 Hz magnetic field IEC 61000 4 8 3 A m 3 A m Power frequency magnetic fields should be at levels characteristic of a typical location in a typical commer...

Page 29: ...in metres m b Field strengths from fixed RF transmitters as determined by an Electromagnetic site survey a should be less than the compliance level in each frequency range b Interference may occur in...

Page 30: ...and mobile RF communications equipment and the EQUIPMENT or SYSTEM for EQUIPMENT and SYSTEMS that are not LIFE SUPPORTING The Infrared Thermometer JPD FR203 is intended for use in an electromagnetic e...

Page 31: ...n from structures objects and people Warranty and After Sale Service The device is under warranty for one year from the date of purchase The batteries the packaging and any damage caused by improper u...

Page 32: ...9 Shenzhen Jumper Medical Equipment Co Ltd Address D Building No 71 Xintian Road Fuyong Street Baoan Shenzhen Guangdong China Tel 86 755 26696279 Fax 86 755 26852035 Website http www jumper medical co...

Reviews: