21
6 Technical data
Galvanic isolation
Without galvanic isolation between sensor
and output
Leakage resistance
> 100 M
Ω
at DC 100 V measured at room
temperature between connection
terminals and case
Reverse polarity
protection
Yes
Voltage supply error
≤
±0.01 % per V deviation from 24 V
The % value refers to the range end value
20 mA
Environmental influences
Ambient temperature
range for head
-30 to +85 °C
Storage temperature
range
-30 to +90 °C
Ambient
temperature error
≤
±(15 ppm/°C × (range end value +200) +
50 ppm/°C × measuring range set) ×
Δυ
Δυ
= deviation of ambient temperature
from the reference temperature
Calibration/reference
conditions
DC 24 V at 25 °C ±5 °C (77 °F ±9 °F)
Climatic conditions
According to IEC 60068-2-30
(rel. humidity
≤
95 % with condensation)
Vibration strength
According to IEC 60068-2-6
(according to GL characteristics)
Electromagnetic
compatibility (EMC)
- interference emission
- interference immunity
DIN EN 61326
class B
industrial requirements
Protection type
IP67 according to DIN EN 60529
with machine connector plugged in