4 Electrical connection

14

4.1

Connection examples

IO-Link operation with 1 switching output

Switch operation with 2 switching outputs

p switching (PNP)

p switching (PNP)

n switching (NPN)

n switching (NPN)

L–

L+

C/Q (IO-Link)

I/Q (OUT2)

BU

BK

WH

BN

1

3

4

2

L–

C/Q (OUT1)

I/Q (OUT2)

L+

BU

BK

WH

BN

1

3

4

2

L–

I/Q (OUT2)

L+

C/Q (IO-Link)

BU

BK

WH

BN

1

3

4

2

L–

C/Q (OUT1)

I/Q

(OUT2)

L+

BU

BK

WH

BN

1

3

4

2

Summary of Contents for dTRANS p35

Page 1: ...40205800T97Z000K000 V5 00 DE EN FR 00656422 2022 10 21 JUMO dTRANS p35 Kurzanleitung Brief Instructions Notice succinte...

Page 2: ......

Page 3: ...40205800T97Z000K000 DE 00656422 2022 10 21 JUMO dTRANS p35 Drucksensor mit IO Link Kurzanleitung...

Page 4: ...k 4 1 3 Hei e Medien 4 1 4 Gefahrstoffe 4 1 5 Zulassungen 5 1 6 Anzeige und Anschlusselemente 5 1 7 Abmessungen 6 2 Ger teausf hrung identifizieren 9 2 1 Typenschild 9 2 2 Bestellangaben 10 2 3 Liefer...

Page 5: ...Sollten bei der Inbetriebnahme Schwierigkeiten auftreten bitten wir Sie keine Manipulationen vorzuneh men die Ihren Gew hrleistungsanspruch gef hrden k nnen Warnende Zeichen VORSICHT Dieses Zeichen i...

Page 6: ...zum Anschluss an Automatisierungssysteme Dem Anwender stehen eine Vielzahl von Druckanschl ssen und Messberei chen zur Verf gung Der Drucksensor ist UL zugelassen Die Zulassung sieht die Verwendung de...

Page 7: ...2022 07 27 E201387 Pr fgrundlage UL 61010 1 3 Ed Mai 2012 revised 19 Juli 2019 und CAN CSA C22 2 No 61010 1 2012 05 3 Ed with revision through 2018 11 Gilt f r Typ 402058 1 Status LEDs 2 Druckanschlu...

Page 8: ...Ausf hrungen 502 504 511 521 und 523 Messbereich 100 bar frontb ndige Ausf hrung 571 574 und 575 Messbereich 100 bar 10 27 66 M12 1 10 27 66 M12 1 Typ 402058 000 XXX 458 997 20 36 000 Typ 402058 000...

Page 9: ...IN 3852 11 A Profildichtung G 1 4 A Profildichtung G 1 2 A Profildichtung G 3 4 G 1 4 19 A 24 5 14 12 20 Nm 27 G 1 2 A 27 26 5 17 14 30 Nm 27 G 3 4 A 32 20 16 30 Nm 32 574 575 612 bis 616 G 1 2 frontb...

Page 10: ...nischer Prozessanschluss f r Adaptersystem JUMO PEKA Ty penblatt 409711 A B 32 5 20 Nm 27 36 20 5 Prozessan schluss DN DN Nominal size D1 D2 DIN 32676 Zoll ISO 2852 612 10 12 27 5 34 15 12 7 20 17 2 2...

Page 11: ...i der IODD Sammlung herunterladen 4 ZIP Datei entpacken 5 ber die Device ID die IODD ermitteln und speichern Die IODD steht nun zur Anwendung mit einem Konfigurationstool des IO Link Masters zur Verf...

Page 12: ...00 bar Relativdruck 516 1 bis 600 bar Relativdruck 488 0 bis 1 bar Absolutdruck 490 0 bis 2 5 bar Absolutdruck 500 0 bis 5 bar Absolutdruck 501 0 bis 12 bar Absolutdruck 503 0 bis 30 bar Absolutdruck...

Page 13: ...a Der Prozessanschluss ist nur f r Eing nge Messbereich bis 100 bar lieferbar b Prozessanschl sse 612 613 und 616 sind nur bei Messspannen bis 25 bar lieferbar c Drossel nur f r nicht frontb ndige Pro...

Page 14: ...Einbaulage ist beliebig HINWEIS Der Drucksensor ist nicht f r sicherheitskritische Anwendungen geeignet HINWEIS Der Drucksensor ist nicht f r die Installation und Anwendung in explosionsgef hrdeten B...

Page 15: ...au L L Schaltausgang 1 4 BK Schwarz C Q OUT1 Schaltausgang 2 2 WH Wei I Q OUT2 IO Link Betrieb Spannungsversorgunga DC 18 bis 32 V 1 BN Braun 3 BU Blau L L IO Link 4 BK Schwarz C Q IO Link Schaltausga...

Page 16: ...usgang Schaltbetrieb mit 2 Schaltausg ngen p schaltend PNP p schaltend PNP n schaltend NPN n schaltend NPN L L C Q IO Link I Q OUT2 BU BK WH BN 1 3 4 2 L C Q OUT1 I Q OUT2 L BU BK WH BN 1 3 4 2 L I Q...

Page 17: ......

Page 18: ...e 36035 Fulda Germany JUMO Mess und Regelger te GmbH Pfarrgasse 48 1230 Wien Austria Technischer Support sterreich Telefon Telefax E Mail Internet 43 1 610610 43 1 6106140 info at jumo net www jumo at...

Page 19: ...40205800T97Z001K000 EN 00656422 2022 10 21 JUMO dTRANS p35 Pressure Sensor with IO Link Brief Instructions...

Page 20: ...3 Hot media 4 1 4 Hazardous materials 4 1 5 Approvals 5 1 6 Display and connection elements 5 1 7 Dimensions 6 2 Identifying the device version 9 2 1 Nameplate 9 2 2 Order details 10 2 3 Scope of del...

Page 21: ...is accessible to all users at all times If difficulties occur during startup please do not intervene in any way that could jeopardize your warranty rights Warning symbols CAUTION This symbol in conne...

Page 22: ...ms A variety of pressure connections and measuring ranges are available to the user The pressure sensor is UL approved The approval stipulates use of the pressure sensor indoors only The protection of...

Page 23: ...7 E201387 Inspection basis UL 61010 1 3 Ed Mai 2012 revised 19 Juli 2019 und CAN CSA C22 2 No 61010 1 2012 05 3 Ed with revision through 2018 11 Valid for Type 402058 1 Status LEDs 2 Pressure connecti...

Page 24: ...ions 502 504 511 521 and 523 measuring range 100 bar Front flush version 571 574 and 575 measuring range 100 bar 10 27 66 M12 1 10 27 66 M12 1 Type 402058 000 XXX 458 997 20 36 000 Type 402058 000 XXX...

Page 25: ...3 4 front flush DIN 3852 11 A Profile seal G 1 4 A Profile seal G 1 2 A Profile seal G 3 4 G 1 4 19 A 24 5 14 12 20 Nm 27 G 1 2 A 27 26 5 17 14 30 Nm 27 G 3 4 A 32 20 16 30 Nm 32 574 575 612 to 616 G...

Page 26: ...enic process connection for adapter system JUMO PEKA data sheet 409711 A B 32 5 20 Nm 27 36 20 5 Process connection DN DN Nominal size D1 D2 DIN 32676 Zoll ISO 2852 612 10 12 27 5 34 15 12 7 20 17 2 2...

Page 27: ...collection of IODDs 4 Extract all files from the ZIP folder 5 Use the device ID to locate the IODD and save it The IODD is now available for use with the IO Link master s configuration tool This can...

Page 28: ...09 1 bar to 400 bar relative pressure 516 1 bar to 600 bar relative pressure 488 0 bar to 1 bar absolute pressure 490 0 bar to 2 5 bar absolute pressure 500 0 bar to 5 bar absolute pressure 501 0 bar...

Page 29: ...on a The process connection can only be supplied for inputs measuring range up to 100 bar b The process connections 612 613 and 616 are only available for mesuring span up to 25 bar c Restrictor only...

Page 30: ...e installed in any position NOTE The pressure sensor is not suitable for safety critical applications NOTE The pressure sensor is not suitable for installation and application in potentially explosive...

Page 31: ...4 BK black C Q OUT1 Switching output 2 2 WH white I Q OUT2 IO Link operation Voltage supplya DC 18 to 32 V 1 BN brown 3 BU blue L L IO Link 4 BK black C Q IO Link Switching output 2 2 WH white I Q OUT...

Page 32: ...output Switch operation with 2 switching outputs p switching PNP p switching PNP n switching NPN n switching NPN L L C Q IO Link I Q OUT2 BU BK WH BN 1 3 4 2 L C Q OUT1 I Q OUT2 L BU BK WH BN 1 3 4 2...

Page 33: ......

Page 34: ...oy Road East Syracuse NY 13057 USA Delivery address Mackenrodtstra e 14 36039 Fulda Germany Phone Fax Email Internet 44 1279 63 55 33 44 1279 62 50 29 sales jumo co uk www jumo co uk Phone Fax Email I...

Page 35: ...40205800T97Z002K000 FR 00656422 2022 10 21 JUMO dTRANS p35 Capteurs de pression avec IO Link Notice succinte...

Page 36: ...ds 4 1 4 Mati res dangereuses 4 1 5 Homologations 5 1 6 El ments d affichage et de raccordement 5 1 7 Dimensions 6 2 Identification de l ex cution de l appareil 9 2 1 Plaque signal tique 9 2 2 R f ren...

Page 37: ...servez la dans un endroit accessible tout moment par l ensemble des utilisateurs Si vous rencontrez des difficult s lors de la mise en service ne proc dez aucune manipulation qui pourrait compromettre...

Page 38: ...dispose d un grand nombre de rac cords de pression et d tendues de mesure Le capteur de pression est homologu UL L homologation pr voit l utilisation du capteur de pression uniquement l int rieur Si...

Page 39: ...2022 07 27 E201387 Base d essai UL 61010 1 3 Ed Mai 2012 revised 19 Juli 2019 und CAN CSA C22 2 No 61010 1 2012 05 3 Ed with revision through 2018 11 S applique Type 902915 1 Leds d tat 2 Raccord de p...

Page 40: ...502 504 511 521 et 523 tendue de mesure 100 bar Ex cutions affleurantes 571 574 et 575 tendues de mesure 100 bar 10 27 66 M12 1 10 27 66 M12 1 Type 402058 000 XXX 458 997 20 36 000 Type 402058 000 XX...

Page 41: ...anch it profil 1 4 G A Joint d tanch it profil 1 2 G A Joint d tanch it profil 3 4 G G 1 4 19 A 24 5 14 12 20 Nm 27 G 1 2 A 27 26 5 17 14 30 Nm 27 G 3 4 A 32 20 16 30 Nm 32 574 575 612 616 1 2 G affle...

Page 42: ...ord de process hygi nique pour syst me d adaptation JUMO PEKA fiche technique 409711 A B 32 5 20 Nm 27 36 20 5 Raccord de pro cess DN DN Nominal size D1 D2 DIN 32676 Zoll ISO 2852 612 10 12 27 5 34 15...

Page 43: ...l onglet Software t l charger le fichier ZIP qui contient toutes les donn es IODD 4 D compresser le fichier ZIP 5 A l aide du Device ID trouver l IODD et le sauvegarder L IODD est maintenant disponib...

Page 44: ...526 1 12 bar pression relative 527 1 30 bar pression relative 515 1 100 bar pression relative 508 1 250 bar pression relative 509 1 400 bar pression relative 516 1 600 bar pression relative 488 0 1 b...

Page 45: ...ntre l humidit et les vibrations am lior e a Le raccord de process peut seulement tre livr pour des entr es tendue de mesure allant jusqu 100 bar b Les raccords de process 612 613 et 616 ne peuvent tr...

Page 46: ...MARQUE Le capteur de pression n est pas adapt des applications sensibles en mati re de s curit REMARQUE Le capteur de pression n est pas con u pour tre install et utilis dans des atmosph res explosibl...

Page 47: ...noir C Q OUT1 Sortie de commutation 2 2 WH blanc I Q OUT2 Mode IO Link Alimentationa 18 32 V DC 1 BN brun 3 BU bleu L L IO Link 4 BK noir C Q IO Link Sortie de commutation 2 2 WH blanc I Q OUT2 Liais...

Page 48: ...sorties de commutation Commande par commutation p PNP Commande par commutation p PNP Commande par commutation n NPN Commande par commutation n NPN L L C Q IO Link I Q OUT2 BU BK WH BN 1 3 4 2 L C Q O...

Page 49: ......

Page 50: ...H B V B A JUMO Mess und Regeltechnik AG 7 rue des Drapiers B P 45200 57075 Metz Cedex 3 France Industriestra e 18 4700 Eupen Belgique Laubisr tistrasse 70 8712 St fa Suisse T l phone T l copieur E Mai...

Page 51: ......

Page 52: ......

Reviews: