Battery replacement:
To avoid false reading, replace the battery when the battery indicator
appears.
Battery Specification: AAA 1.5Vx2
1) Switch the dial to “OFF “position and remove the test leads from the input terminal.
2) Take off the protective case. Loosen the screw on battery cover, remove the cover to replace the
battery. Please identify the positive and negative pole.
Fuse replacement:
1) Switch the dial to “OFF “position and remove the test leads from the input terminal
2) Loosen the both screws on the rear cover, then remove the rear cover to replace the fuse
Fuse specification
F1 Fuse 0.2A/250V Φ5×20mm Ceramic tube
F2 Fuse 10A/250V Φ5×20mm Ceramic tube