UT131 Palm Size Multimeter
-28-
200.0V
0.1V
±(0.7%+3)
250V
1V
±(0.7%+3)
Input impedance: about 10MΩ ,
Results might be unstable at mV range when no load is connected. The value becomes stable
once the load is connected. Least significant digit ≤±3
Max input voltage: ±250V
, when the voltage≥ 610V, "OL " symbol appears.
Overload protection: 250Vrms(AC/DC)
2. AC voltage
Range
Mode
Resolution
Accuracy
200.0mV
UT131A
0.1mV
±(1.0%+2)
2.000V
UT131A
0.001V
±(0.7%+3)
20.00V
UT131A
0.01V
±(1.0%+2)
200.0V
UT131A/B/C/D
0.1V
±(1.2%+3)
250V
UT131A/B/C/D
1V
±(1.2%+3)