FOLDER ADJUSTMENT
Slide folder (A, Fig. 22) on arm. The folder should be as close to
the front of presser foot (B) as possible, making sure to avoid the
presser foot contacting the folder when sewing across seams. If
adjustment is necessary loosen screws (C) to move entire folder
left to right or front to back as required. If just adjustment of
upper scroll (D) is needed loosen screw (E) and position scroll to
obtain proper seam margin.
AIR BLOWER TUBE ADJUSTMENT
The air blower tube should be set left to right so it is parallel with
the throat plate. It should be set front to back so when feeding
over a cross seam the presser foot does not contact the tube. If
adjustment is necessary, loosen screw (A, Fig. 23) and position
air blower tube (B) as required. Retighten screw (A).