– 49 –
No
Item
Setting range
U211
Number of stitches for
sewing the material while
the sewing counter is
enabled
0 to 2000 stitches This memory switch data item is used for setting the number
of stitches to be sewn before allowing the sewing counter to
start counting. The sewing counter will not perform counting
unless the sewing machine has performed sewing by the pre-
set number of stitches or more while the presence of material
is detected.
U226
Material thickness sensor
value without material
0 to 3000
This memory switch data item is used for setting the material
thickness sensor value when the presser foot is lowered with
the feed dog lowered without material. If this value is not cor-
rect, the presser foot pressure cannot be corrected properly.
U401
Stitch-length input unit
0 to 2
0:Stitch length (mm)
1:Number of stitches per inch
2:Number of stitches in 3 cm
U402
Automatic lock time
0 to 300 second
This memory switch data item is used for setting the period
of time to be passed, in the state the operation panel is not
operated, before the automatic lock function is actuated.
U403
Automatic OFF of the
back light
0 to 20
This memory switch data item is used for setting the period
of time to be passed, in the state the operation panel is not
operated, before the back light for the operation panel is auto-
matically turned OFF.
0 : Not turn OFF automatically
1 - 20 : Period of time until the back light is automatically
turned OFF (in minute)
U404
Selection of display be-
tween the "part number
and process" and "com-
ment"
0 to 1
This memory switch data item is used for selecting either the
"part number and process" or the "comment" is displayed on
the sewing screen.
0: Part number and process
1: Comment
U406
Language selection
-
Not selected /
Japanese /
English /
Simplified
Chinese /
Spanish /
German /
French /
Italian /
Turkish
U407
Operation sound for the
operation panel
0 to 1
0
:
OFF
1
:
ON