– 29 –
③
Cloth puller runs on the top of material
Setting of the sewing data to be used when the top
of material is fed to reach the cloth puller is carried
out.
State display on the operation panel:
* Depending on the "S034 The number of stitches
at which the presser foot pressure is changed at
the beginning of sewing the top of material" and
the "S074 The number of stitches from which the
cloth puller runs on the top of material", the state
of the presser foot side may remain in the "state
of sewing the top end of material".
* If the top of material is caught in the cloth puller, change the setting appropriately.
When the sewing machine completes sewing of "S075 The number of stitches at which the cloth puller runs
on the top of material" in the "state the cloth puller runs on the top of material", the sewing state shifts to the
"flat section state".
S004 Limit of sewing speed
S005 Presser foot pressure
S077 Cloth puller pressure when the cloth puller runs on the top end of material
S076 Cloth pulling amount when the cloth puller runs on the top end of material
S074 Number of stitches at which the cloth puller starts running on the top end of material
S075 Number of stitches while the cloth puller runs on the top end of material
S005 Presser foot pressure
S007 Cloth puller pressure
S006 Cloth pulling amount
Parameter
④
While the sewing machine sews a flat section of material
Setting of the sewing data for normal sewing is car-
ried out.
State display on the operation panel:
The following data items are used.
S004 Limit of sewing speed
S005 Presser foot pressure
S007 Cloth puller pressure
S006 Cloth pulling amount
When the measured value by the multi-layered section sensor reaches the "S011 Multi-layered section
changeover sensor ON" value or more, the sewing state shifts to the "state of running on the multi-layered
section".
* The multi-layered section detection timing can be advanced by decreasing the "S011 Multi-layered
section changeover sensor ON" set value. Be aware, however, that false detection of the multi-lay-
ered section can occur if the timing is advanced excessively.