– 30 –
No
Item
Description
Range
Initial value
P31
Number of stitches for
keeping the intermittent
suction in the operating
state for pedal control suc
-
tion 1
In the case "6" is selected for "P17", the suction 1 is
kept in the operating state for the number of stitches set
for this function setting number "P31" during sewing.
The suction 1 carries out operation and non-operation
of suction alternately in repetition.
0-200
50
P32
Number of stitches for
keeping the intermittent
suction in the stopped state
for pedal control suction 1
In the case "6" is selected for "P17", the suction 1 is
kept in the stopped state for the number of stitches set
for this function setting number "P32". The suction 1
carries out operation and non-operation of suction alter
-
nately in repetition.
In the case this function setting number is set to "0", the
sewing machine will carry out the same operation as it
carries out when the function setting number "P17" is
set to "4: Long suction" regardless of the set value of
the function setting number "P31".
0-200
50
P33
Number of stitches for
keeping the intermittent
suction in the operating
state for pedal control suc
-
tion 2
In the case "6" is selected for "P22", the suction 2 is
kept in the operating state for the number of stitches set
for this function setting number "P33" during sewing.
The suction 2 carries out operation and non-operation
of suction alternately in repetition.
0-200
50
P34
Number of stitches for
keeping the intermittent
suction in the stopped state
for pedal control suction 2
In the case "6" is selected for "P22", the suction 2 is
kept in the stopped state for the number of stitches
set for this function setting number "34". The suction 2
carries out operation and non-operation of suction alter
-
nately in repetition.
In the case this function setting number is set to "0", the
sewing machine will carry out the same operation as it
carries out when the function setting number "P22" is
set to "4: Long suction" regardless of the set value of
the function setting number "P33".
0-200
50
P35
Number of pieces
This function setting number is used for counting the
number of pieces produced.
0-9999
0
P36
Number of times of thread
trimming for sewing one
piece of product
This function setting number is used for setting the num
-
ber of times of thread trimming to be carried out before
adding one to the current number of counts of "P35".
1-50
10
P40
N1-N2
N1: Electrical box software version;
N2: Operation panel software version
Summary of Contents for MO-6800DD10 Series
Page 1: ...MO 6800S D DD10 Series INSTRUCTION MANUAL...
Page 14: ...12 MO 6814 44H MO 6816...
Page 15: ...13 MO 6816 50H MO 6816 60H...
Page 44: ...42 1200 Unit mm Difference 2 10 TABLE DRAWING Black scale marker line A A B B...