– 50 –
10. TIMING CHART
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
3000rpm
120rpm
Soft start
Needle Up by
reverse revolution
TE
L2
K11
TS
LS
170rpm
SC-380 program mode (standard adjustment value)
G mode
• TS (Thread trimming ON timing)
: 64
• TE (Thread trimming OFF timing) : 122
• LS (Tension release ON timing)
: 180
• L2 (Tension release OFF timing) : 20
When thread trimming failure occurs, change the value of TS.
At this time, change the value of TE as “TS + TE = 186” as well.
Thread trimming signal
DOWN position
UP position
Sewing machine
Thread trimming
solenoid valve output
Tension release
solenoid output
Condensation solenoid
valve output
Threading switch input
Threading solenoid
valve output
Thread trimming