– 14 –
❺
❻
❶
❷
❸
❹
(3) Releasing procedure of the grease-up “error” For SC-920
When using the machine for a certain period of time after the display of error No. 220 (continuing using the
machine without performing grease-up at the time of displaying No. 220), error No. 221 is displayed and the
machine stops running.
In this case, apply grease to the specified sections, then reset the error according to the description given in
"(2) Releasing procedure of the grease-up warning for SC-920" p.13
After completion of the operation, turn the power OFF and re-turn it ON to restore the normal operation.
5) When setting No.
❻
is adjusted
to "118", the current set value is
displayed on LED
❺
. Then Press
switch
❹
(switch
❸
) to
change to "1".
6) When the change has been com-
pleted, press switch
❷
or
❶
to specify the changed value.
4-7. Setting up the SC-920
Supply voltage
3-phase 200 to 240V
Frequency
50Hz/60Hz
Operating envi-
ronment
Temperature : 0 to 40˚C
Humidity : 90% or less
Input
320VA
(1) Specifications
(2) Installing on the table (LH-3528A-7, 3568A-7, 3578A-7 and 3588A-7)
After completion of the operation, turn the power OFF and re-turn it
ON to restore the normal operation.
1) Hammer decoration bolt
❶
supplied with the LH-
3500A into table.
The decoration bolt supplied with the SC-
920 is not used.
❶
Parts supplied with SC-920
Parts supplied with LH-3500A
❻
❼
❹
❸
❶
❽
❾
×
Table
Operator side
When turning OFF the pow-
er before performing this
work, the contents which
have been changed are not
updated.