– 69 –
Error code
Description
How to recover
Place of recovery
E487
Eyelet shape length error
Eyelet shape length is too short to form the
shape in case of eyelet shape.
Possible to re-en-
ter after pressing
reset key.
(During individual sewing/cycle
sewing)
Sewing data edit screen
[S014] Eyelet shape length
(During continuous sewing)
Standard screen
E488
Taper bar-tacking compensation error
When bar-tacking length is too short to form
the shape in case of taper bar-tacking shape.
Possible to re-en-
ter after pressing
reset key.
(During individual sewing/cycle
sewing)
Sewing data edit screen
[S008] 2nd bar-tacking length
(During continuous sewing)
Standard screen
E489
Knife size error (at the time of plural mo-
tions of knife)
When knife size is larger than cloth cutting
knife size.
Possible to re-en-
ter after pressing
reset key.
(During individual sewing/cycle
sewing)
Sewing data edit screen
[S002] Cloth cut length
(During continuous sewing)
Standard screen
E492
Presser size over of basting
When stitching data of basting exceeds
presser size.
Possible to re-en-
ter after pressing
reset key.
(During individual sewing/cycle
sewing)
Sewing data edit screen
[S040] Basting needle entry com
-
pensation
(During continuous sewing)
Standard screen
E493
Presser size over of tie stitching at sewing
end
When stitching data of tie stitching at sewing
end exceeds presser size.
Possible to re-en-
ter after pressing
reset key.
(During individual sewing/cycle
sewing)
Sewing data edit screen
[S067] Tie stitching at sewing end
width
(During continuous sewing)
Standard screen
E494
Presser size over of tie stitching at sewing
start
When stitching data of tie stitching at sewing
start exceeds presser size.
Possible to re-en-
ter after pressing
reset key.
(During individual sewing/cycle
sewing)
Sewing data edit screen
[S064] Tie stitching at sewing start
width
(During continuous sewing)
Standard screen
E495
Presser size error (Width direction : right
only)
When stitching data exceeds the size of right
only of width direction of presser.
Possible to re-en-
ter after pressing
reset key.
(During individual sewing/cycle
sewing)
Sewing data edit screen
[S003] Knife groove width, right or
[S006] Ratio of right and left shapes
(During continuous sewing)
Standard screen
E496
Presser size error (Width direction : left
only)
When stitching data exceeds the size of left
only of width direction of presser.
Possible to re-
enter after pressing
reset key.
(During individual sewing/cycle
sewing)
Sewing data edit screen
[S004] Knife groove width, left or
[S006] Ratio of right and left shapes
(During continuous sewing)
Standard screen
E497
Presser size error (Length direction : front)
When stitching data exceeds the size of front
of length direction of presser.
Possible to re-
enter after pressing
reset key.
Standard screen
E498
Presser size error (Width direction : right
and left)
When stitching data exceeds the size of both
right and left of width direction of presser.
Possible to re-
enter after pressing
reset key.
(During individual sewing/cycle
sewing)
Sewing data edit screen
[S005] Overedging width, left
(During continuous sewing)
Standard screen