![JUKI 35800 Series Engineer'S Manual Download Page 19](http://html1.mh-extra.com/html/juki/35800-series/35800-series_engineers-manual_2029575019.webp)
– 15 –
1. Checking procedure of needle entry
(1) Mount 3 needles
to the needle clamp
and tighten the setscrew
.
(2) Loosen the needle bar holding screw
, set the temporary needle
bar
height (12.5 mm), and tighten the needle bar holding screw
{6} temporarily (approximately 4 turns of the needle bar
).
(3) Insert the torque rod
into the hole at the top of the needle bar
and rotate the needle bar
in the right-left direction to adjust the
needle entry position in the front-rear and right-left directions.
(Caution) 1. When the needle
position is not in the center of
the needle hole of the throat plate
in the right-left
direction, follow the procedure below.
2. For needle entry adjustment, mount the rear needle
guides temporarily and make sure that 3 needles
touch evenly.
2. Needle entry adjustment
(1) For adjusting the needle entry position in the right-left direction,
remove 6 setscrews
securing the front top cover
to remove
the front top cover
and packing
.
(2) Loosen the hexagon head bolt
, engage a driver with the eccentric
pin
, and rotate the driver in the right-left direction. Then, the
sylinder arm moves in the right-left direction.
(3) Adjust the needle entry position in the right-left direction.
o Rotation of the eccentric pin
clockwise moves the cylinder arm
leftward.
o Rotation of the eccentric pin
counterclockwise moves the cylinder
arm rightward.
(4) After adjustments, tighten the hexagon head bolt
.
(5) After adjusting the needle entry position, put the front top cover
and packing
back on and tighten the setscrew
.
o Improper needle entry position
adjustment may cause stitch
skipping, needle breakage, or
thread breakage.
Adjustment Procedures
Results of Improper Adjustment