JUDO SPEEDY-LongLife
9
Installation
4.1.4 Installing the backwash
protective filter
The filter is connected using the supplied
built-in rotary flange. It consists of the built-
in rotary flange and a profiled flange seal.
Undo the union nuts of the built-in rotary
flange and fit to the pipe with the sleeve.
Note the installed dimensions!
Position the filter with pre-fitted built-in rotary
flange between the sleeves, insert the flat
seals and screw using the union nut.
The cast in arrow of the built-in rotary flange
must match the direction of flow of the water.
ATTENTION
(see chapter “Safety information and
dangers due to non-compliance”)
The section of the profiled flange gasket
must point towards the built-in rotary flange
(see fig. 4). Failure to observe this can lead
to leaks and water escaping. This can in turn
cause water damage to the house and its
installations.
Select the torque (approx. 4 Nm) so
that the gasket closes and the filter
is not damaged or strained!
Fig. 3: Built-in rotary flange