background image

Attention:
Carefully read through the instal-
lation and operating instructions
and safety information before
installing and putting the unit into
service.
These instructions must always
be issued to the owner/user.

Installation and 
operating instructions

                  JUDO HEIFI-TOP ¾" - 2"

Backwash filter with deaeration system 

Model JHF-T

Valid for: Canada

 Fig.: JHF-T 1½" - 2"

Fig.: JHF-T ¾" - 1¼"

Summary of Contents for JHF-T

Page 1: ...safety information before installing and putting the unit into service These instructions must always be issued to the owner user Installation and operating instructions JUDO HEIFI TOP 2 Backwash fil...

Page 2: ...Customer we would like to thank you for your con fidence in us which you have shown by purchasing this device The product you have purchased is a filter developed us ing state of the art technology Th...

Page 3: ...e place where the filter is installed This instruction manual is intended to make it easier to familiarize yourself with the filter and its possible intended uses The instruction manual contains impor...

Page 4: ...to observe the general danger symbols can result for example in the following risks Failure of important functions of the filter Danger to persons due to electrical and mechanical effects Danger to p...

Page 5: ...prior to any operation of the filter other than in the operational areas stated in these operating instructions The filter may only be operated in a techni cally faultless condition in accordance with...

Page 6: ...d per sonnel The chapter Intended use must always be observed The pipes must be able to safely support the filter Otherwise mechanical damage or fractures bursts can occur in the pipes This can result...

Page 7: ...uilt in rotary flange is used as a connecting element between the pipe and the filter The built in rotary flange is suitable both for horizontal and vertical pipes It is suitable for both horizontal a...

Page 8: ...as far as it will go see fig 2 II Tighten the four flange screws ATTENTION see chapter Safety information and dangers due to non compliance The section of the profiled flange gasket must point toward...

Page 9: ...ening the ball valve the filter is backwashed see chapter Backwashing Caution risk of scalding After approx 2 to 3 liters of backwashing wa ter has been flushed through the ball valve must be tightly...

Page 10: ...ugh of the device is brought about Step 1 min 10 liter Step 2 Fig 6 The backwash performance will be started through the turning on of the flush faucet Hold available a collecting vessel with a capaci...

Page 11: ...utlet of the rapid venter is in a one turn open position to ensure an unhindered escape of the air After backwashing and venting the filter is ready for use Functional description 5 2 Functional descr...

Page 12: ...illing water must be refed 5 4 Backwashing interval If the filter is installed retrospectively in old heating systems the backwashing should be carried out every 14 days until the back washing water c...

Page 13: ...s not yet been turned back Ball valve handle at the front Turn the handwheel back to the right up to the limit stop The filter is now back in the operating position The heating system s circulating pu...

Page 14: ...se cleaners and glass cleaners can contain up to 25 solvents or alcohol spirits These substances can chemically attack the plastic parts which can lead to brittleness right up to brittle fractures The...

Page 15: ...F T 1 8060056 JHF T 2 8060057 Nominal pressure Model Operating pressure Nominal pressure JHF T 2 22 150 psi 150 1000 kPa PN 10 Weight Model Weight JHF T 4 9 kg JHF T 1 5 0 kg JHF T 1 5 5 kg JHF T 1 13...

Page 16: ...E Depth to pipe centre F Connection dimension residual water G Nominal diameter Model A B C D E F G JHF T 180 7 0 130 5 0 245 10 138 5 4 170 6 7 105 4 1 15 0 6 JHF T 1 195 7 5 130 5 0 245 10 138 5 4...

Page 17: ...JQE 1 or 2 with bayonet fixture and screw connection 9 7 Accessories JHF T 2 JHF F feed station Order no 8060040 The JUDO HEIFI F L feed station consists of a ball valve pressure reducer and manometer...

Page 18: ...18 JUDO HEIFI TOP Spare parts 10 Spare parts 9 10 11 13 12 8 7 6 5 4 3 2 2 14 15 1...

Page 19: ...3 Housing JUDO HEIFI TOP 1 2060073 4 Circular brush diameter 60 1 1980214 5 Clamping nut 1 2060061 6 Dowel pin 4m6x10 1 1650226 7 Pressure spring 1 1650224 8 Lock housing 1 2060062 9 Shut off valve 1...

Page 20: ...ved for modifications as a result of technical progress or further developments Claims with regard to models or products are excluded 1701610 2017 01 JUDO Water Treatment Inc 240 Lesmill Road Toronto...