background image

JUDO GUBi-E

7

Installation

4.

Installation

4.1

General

ATTENTION

(See chapter on “Safety information and
dangers due to non-compliance”)

The unit may only be installed by skilled per-
sonnel.

The chapter on “Intended Use” must always
be observed!

The pipes must be able to safely support the
Domestic Water.

Otherwise mechanical damage or fractures/
bursts can occur in the pipes. This can result
in major water damage. People close to the
Domestic Water are exposed to a health risk
due to the large quantities of water released.
Therefore, if necessary, the pipes must be
additionally fixed or supported.

For convenient operation and maintenance
it is absolutely necessary to ensure the giv-
en spacings (see chapter “Discharging the
backwashing water”).

A space of at least 200mm should be main-
tained above and below the Domestic Water
station. These distances are necessary to
be able to properly carry out the backwash-
ing (see chapter “Backwashing”).

(See chapter on “Modifications / changes /
spare parts”)

4.1.1 Requirements for the place of 

installation

The room where the unit is installed must
be dry and frost free!

Unauthorised persons must not have ac-
cess to the Domestic Water!

ATTENTION

(See chapter on “Safety information and
dangers due to non-compliance”)

The ambient temperature must not ex-
ceed 30°C (86°F)! At higher tempera-
tures or direct sun radiation the material
can be damaged and the filter hood can
even break.

In order to be able to safely discharge
the wastewater in operation and in case
of any defects that occur in the system,
precise compliance with the details giv-
en in the “Installation” chapter is neces-
sary!

If the wastewater (backwashing) cannot
be safely and completely discharged,
the house and installations can be dam-
aged by water.

A shut-off valve must be installed up-
stream and downsteam of the Domestic
Water with a bypass to allow continued
water supply when the Domestic Water
is out of service! This enables the water
supply to the Domestic Water to be inter-
rupted during installation, servicing/
maintenance, repairs and in case of mal-
functions. Floods and serious water
damage to house installations can there-
fore be avoided.

The unit can be installed in all standard
drinking water pipes.

It is not permitted to install the Domestic
Water 

upstream of 

the

 

water meter!

Summary of Contents for GUBi-E

Page 1: ...n before installing and putting the unit into service These must always be issued to the owner user Extended warranty peri od if a service agreement is concluded Installation and Operating Instruction...

Page 2: ...permitted with special approval Dear Customer Thank you for the confidence you have shown in us by purchasing this unit With this Domestic Water you have purchased a state of the art unit This Domesti...

Page 3: ...must be permanent ly available at the place in which the Domes tic Water is used This instruction manual is intended to make it easier to familiarize yourself with the Domestic Water and its possible...

Page 4: ...nd dan gers due to non compliance In detail failure to observe the general dan ger symbols can result for example in the following risks Failure of important functions of the Domestic Water Danger to...

Page 5: ...supplier must always be consulted before using the Domestic Water outside the use limitations given in the in struction manual The Domestic Waters are only to be used in a technically perfect conditi...

Page 6: ...ns for drinking water installations in ac cordance with DIN 1988 They are tested by the DVGW Deutsche Vereinigung des Gas und Wasserfaches e V technical scientific association for the gas and water in...

Page 7: ...m where the unit is installed must be dry and frost free Unauthorised persons must not have ac cess to the Domestic Water ATTENTION See chapter on Safety information and dangers due to non compliance...

Page 8: ...age can result the pipe may burst or the built in rotary flange can break This can re sult in major water damage In this case people close to the Domestic Water are exposed to a health risk due to the...

Page 9: ...er can be fed several metres to the next wastewater connection either through a hose or a pipe to be fitted to the flushing water valve This pipe must have the same dimension as the flushing water val...

Page 10: ...vented by means of backwashing see chapter Di scharging the backwashing water After backwashing and venting the Do mestic Water station is ready for use 5 2 Pressure setting Change the factory set pr...

Page 11: ...ed dirt from the fine filter screen The backwashing takes place at full tap wa ter system pressure To clean the screen the backwashing handwheel 9 is turned in an anti clockwise direction up to the li...

Page 12: ...om high water consumption this can also cause water damage especially if the backwash ing water is not discharged as described in the chapter Discharging the backwashing water 5 4 1 Backwashing interv...

Page 13: ...n and dangers due to non compliance Only original spare parts are to be used Independent modifications and changes are prohibited for safety reasons These can im pair the function of the Domestic Wate...

Page 14: ...d leak tightness only approved persons may open the units and replace parts subject to water pressure Help with faults Fault Cause Remedy Backwashing water con tinues running Flushing valve not fully...

Page 15: ...the legal warranty claim according to DIN 1988 Part 8 it is necessary that the backwashing takes place at least every 2 months after operat ing conditions exist Further an annual check of the set disc...

Page 16: ...sure class according to which the Domestic Wa ter must fulfil the requirements to DIN 19632 The maximum operating pressure is lower in order to ensure the optimum func tion of the Domestic Water The b...

Page 17: ...1 x Built in rotary flange JQE 1 or 1 with bayonet fixture and screw con nection 9 6 Accessories JUDO JQR expansion quickset Order no 8250041 for the series connection of two devices e g filter and w...

Page 18: ...18 JUDO GUBi E Spare Parts JGB E 1 10 Spare Parts JGB E 1...

Page 19: ...10390 20 9 Display button 1 1120424 2 10 Profile flange seal 2 1200218 5 11 Cylinder screw M6 x 25 coated 4 2010199 2 12 Sieve 1 2150015 68 13 Suction Pipe Gasket 1 1607410 3 14 Self tapping screw 1 1...

Page 20: ...fo judo online be www judo online be JUDO Austria Zur Schleuse 5 A 2000 Stockerau Tel 43 0 2266 6 40 78 Fax 43 0 2266 6 40 79 e mail info judo online at www judo online at Installed by JUDO BIOQUELL S...

Reviews: