About this Instruction Manual

Table of Contents
1. About this Instruction Manual.......... 3

1.1 Symbols used .............................. 4

1.2 Safety information and dangers 

due to non-compliance ................ 4

1.3 Units used.................................... 4

2. Intended Use ...................................... 5

2.1 Water Pressure............................ 5

2.2 Instructions Concerning Specific 

Dangers ....................................... 5

3. Product Information .......................... 6

3.1 Intended purpose......................... 6

3.2 Test marks .................................. 6

3.3 Materials used ............................. 6

4. Installation ......................................... 7

4.1 General ........................................ 7

4.2 Discharging the

backwashing water ...................... 9

5. Operation ......................................... 10

5.1 Commissioning .......................... 10

5.2 Pressure setting......................... 10

5.3 Functional description................ 11

5.4 Backwashing ............................. 11

5.5 Modifications / changes / spare 

parts........................................... 13

5.6 Stoppages ................................. 13

6. Faults ................................................ 14
7. Maintenance..................................... 15

7.1 Cleaning .................................... 15

8. Warranty and Services.................... 15
9. Data Sheet ........................................ 16

9.1 Type........................................... 16

9.2 Models ...................................... 16

9.3 Technical specifications............. 16

9.4 Installed dimensions ¾" - 1¼"  .. 17

9.5 Scope of supply ......................... 17

9.6 Accessories ............................... 17

10. Spare Parts JGB-E ¾" – 1¼" .......... 18
11. Customer Support ........................... 20

Enclosure: Consultation Voucher

1.

About this Instruction 
Manual

ATTENTION

(See chapter on “Safety information and
dangers due to non-compliance”)

The instruction manual must be permanent-
ly available at the place in which the Domes-
tic Water is used.

This instruction manual is intended to make
it easier to familiarize yourself with the
Domestic Water and its possible intended
uses.

The instruction manual contains important
information in order to safely, properly and
economically run the Domestic Water.

It contains fundamental information, which
must be observed during installation, opera-
tion and maintenance. Observance of this
information helps to avoid dangers, reduce
repair costs and increase the reliability and
service life of the Domestic Water.

The instruction manual must be read and
used by each person entrusted with carrying
out work on the Domestic Water, for exam-
ple:

installation

Operation

Maintenance

 (servicing, inspection, re-

pair)

Installation and maintenance may only be
carried out by personnel authorized by the
manufacturer, who are capable of fulfilling
the instructions given in the installation and
operating instructions and the country-spe-
cific regulations.

Apart from the instruction manual and the le-
gally binding accident prevention provisions
applicable in the country and place of use,
the recognized technical regulations for safe
and proper work must also be observed.

Summary of Contents for GUBi-E

Page 1: ...n before installing and putting the unit into service These must always be issued to the owner user Extended warranty peri od if a service agreement is concluded Installation and Operating Instruction...

Page 2: ...permitted with special approval Dear Customer Thank you for the confidence you have shown in us by purchasing this unit With this Domestic Water you have purchased a state of the art unit This Domesti...

Page 3: ...must be permanent ly available at the place in which the Domes tic Water is used This instruction manual is intended to make it easier to familiarize yourself with the Domestic Water and its possible...

Page 4: ...nd dan gers due to non compliance In detail failure to observe the general dan ger symbols can result for example in the following risks Failure of important functions of the Domestic Water Danger to...

Page 5: ...supplier must always be consulted before using the Domestic Water outside the use limitations given in the in struction manual The Domestic Waters are only to be used in a technically perfect conditi...

Page 6: ...ns for drinking water installations in ac cordance with DIN 1988 They are tested by the DVGW Deutsche Vereinigung des Gas und Wasserfaches e V technical scientific association for the gas and water in...

Page 7: ...m where the unit is installed must be dry and frost free Unauthorised persons must not have ac cess to the Domestic Water ATTENTION See chapter on Safety information and dangers due to non compliance...

Page 8: ...age can result the pipe may burst or the built in rotary flange can break This can re sult in major water damage In this case people close to the Domestic Water are exposed to a health risk due to the...

Page 9: ...er can be fed several metres to the next wastewater connection either through a hose or a pipe to be fitted to the flushing water valve This pipe must have the same dimension as the flushing water val...

Page 10: ...vented by means of backwashing see chapter Di scharging the backwashing water After backwashing and venting the Do mestic Water station is ready for use 5 2 Pressure setting Change the factory set pr...

Page 11: ...ed dirt from the fine filter screen The backwashing takes place at full tap wa ter system pressure To clean the screen the backwashing handwheel 9 is turned in an anti clockwise direction up to the li...

Page 12: ...om high water consumption this can also cause water damage especially if the backwash ing water is not discharged as described in the chapter Discharging the backwashing water 5 4 1 Backwashing interv...

Page 13: ...n and dangers due to non compliance Only original spare parts are to be used Independent modifications and changes are prohibited for safety reasons These can im pair the function of the Domestic Wate...

Page 14: ...d leak tightness only approved persons may open the units and replace parts subject to water pressure Help with faults Fault Cause Remedy Backwashing water con tinues running Flushing valve not fully...

Page 15: ...the legal warranty claim according to DIN 1988 Part 8 it is necessary that the backwashing takes place at least every 2 months after operat ing conditions exist Further an annual check of the set disc...

Page 16: ...sure class according to which the Domestic Wa ter must fulfil the requirements to DIN 19632 The maximum operating pressure is lower in order to ensure the optimum func tion of the Domestic Water The b...

Page 17: ...1 x Built in rotary flange JQE 1 or 1 with bayonet fixture and screw con nection 9 6 Accessories JUDO JQR expansion quickset Order no 8250041 for the series connection of two devices e g filter and w...

Page 18: ...18 JUDO GUBi E Spare Parts JGB E 1 10 Spare Parts JGB E 1...

Page 19: ...10390 20 9 Display button 1 1120424 2 10 Profile flange seal 2 1200218 5 11 Cylinder screw M6 x 25 coated 4 2010199 2 12 Sieve 1 2150015 68 13 Suction Pipe Gasket 1 1607410 3 14 Self tapping screw 1 1...

Page 20: ...fo judo online be www judo online be JUDO Austria Zur Schleuse 5 A 2000 Stockerau Tel 43 0 2266 6 40 78 Fax 43 0 2266 6 40 79 e mail info judo online at www judo online at Installed by JUDO BIOQUELL S...