background image

                                             Page  3/4 

                                                      

The Quality Connection 

 

 

Crimping Operation: 
 

1)

 

Squeeze the handles until the dies are completely 
closed.  The Ratchet will release allowing the 
handles to open.

 

2)

 

Remove the adjustment pin from the upper die and 
then remove the upper die from the tool. 

 

3)

 

Select the side that matches the wire size that will be 
used.

 

4)

 

 Refer to Fig. 2. Position the upper die and insert it 
so the guide screw is inserted in the guide groove of 
the upper die (on the insulation barrel side).  The 
guide screw prevents the die from being inserted the 

wrong way. Do not remove the guide screw.  

 

5)

 

Insert the carrier strip of the terminals into the tool 
between the terminal guide and the guide plate. The 
insulation barrel of the terminal must be fed into the 
groove on the guide plate as shown in Fig. 3. Feed 

the terminals into the tool by hand until the first 
terminal is in the crimping position over the anvils. 

 

6)

 

With the terminal in the crimping position lightly 
squeeze the handles together until the upper 
crimper touches the insulation barrel. Do not put 

too much pressure on the terminal at this point. 
Deforming the terminal will prevent the wire from 
being inserted.

 

7)

 

Insert a stripped wire into the upper die until the 
insulation of the stripped wire lightly touches the 
stripper as shown in Fig.4.  

 

8)

 

Holding the wire in the correct  position squeeze 
the handles until the ratchet releases.

 

9)

 

Remove the terminal and make a visual inspection 
of the completed crimped terminal.

 

 
 