1. The Motor does not run
(1) The Power cord is disconnected
Reconnect the power cord.
(2) The Power cord is damaged
Replace the power cord
(3) A solder joint on the Power Cord metal
plug is bad
Resolder the joint
(4)
The Fuse Blows
Unscrew the fuse holder on the front of the control
box, and replace with the correct fuse.
6.3 A “Anti-surge” fuse.
WARNING:DISCONNECT FROM THE MAINS
BEFORE UNSCREWING!
(5)
Stop/Reset is pressed
The machine will not operate, press the stop/reset
button again to reset the press.
(6)
The Belt Cover is open
Close the belt cover and re-secure the catch with
the cap head socket screws.
2. The Ram does not move
(1) The Connecting Pin is broken
Replace the connecting pin with a new one
.