6. SAFETY PRECAUTIONS: 

•  PowerCap Active should only be used in situations where EN 12941:TH1 and EN 812:1997 – A1:2001 apply. 

•  PowerCap Active does not provide protection against the effects of falling or thrown objects, or moving suspended loads. 

•  PowerCap Active should not be used instead of an Industrial Safety Helmet as specified in EN 397. 

•  The instructions inside PowerCap Active should be read and understood as well as these instructions before use.

WARNINGS!

•  THIS APPARATUS MUST NOT BE WORN WITH THE BLOWER UNIT SWITCHED OFF. 

•  WHEN SWITCHED OFF A RAPID BUILD UP OF CARBON DIOXIDE AND DEPLETION OF OXYGEN MAY OCCUR.

•  WHEN SWITCHED OFF NO RESPIRATORY PROTECTION IS PROVIDED.

•  THE APPARATUS SHOULD NOT BE USED IN EXPLOSIVE OR OXYGEN DEFICIENT ATMOSPHERES

•  AT HIGH WORK RATES THE PRESSURE IN THE DEVICE MAY BECOME NEGATIVE AT PEAK INHALATION FLOW. 

•  USING THE APPARATUS IN HIGH WIND VELOCITIES MAY AFFECT FILTERING EFFICIENCY. 

PowerCap Active is not designed for use in atmospheres that are immediately hazardous to user hygiene or health, have less than 19.5% oxygen content, contain gases or toxic 

substances, or unknown compositions. 

•  DO NOT use PowerCap Active in an explosive atmosphere.  •   DO NOT expose PowerCap Active to flames or sparks.   •   DO NOT use PowerCap Active in confined spaces 

or areas of poor ventilation.   •   DO NOT alter or modify the product in any way.   •   DO NOT touch any moving part.   •   DO NOT allow water or other liquids to enter the inside of 

the motor housing or battery compartment.

PowerCap Active Lite:

The visor is of lightweight construction and does not provide a high degree of eye protection. In situations where there is any risk to the eyes from 

projectiles (for example when strimming) approved type Safety Spectacles must also be worn in the normal way “within PowerCap Active”, i.e. Behind the visor. The PowerCap 

Active airflow will help to prevent “fogging” of both the Spectacles and the Visor.

PowerCap Active IP:

 The visor is manufactured of Polycarbonate and has been tested according to EN166:1995, the standard for Personal eye-protection. 

As required by European Health and Safety requirements, the user is advised that when in contact with the wearers skin, the unit may cause allergic reactions to susceptible 

individuals. If this is the case the wearer should leave the hazard area, remove the unit and seek doctor’s advice.

7. GUARANTEE:

PowerCap Active is guaranteed for a period of 12 months from date of purchase against mechanical or electrical defects. The Company undertakes to exchange or repair without 

charge, any part to be found defective within this specified period. Alternatively and at its discretion, the Company may replace them.
This guarantee is subject to:- PowerCap Active has been used solely for the purpose for which it is intended. PowerCap Active has not been subject to misuse, accident, 

modification or repair. 

N.B. In the event of a claim, contact the retailer from which the PowerCap Active was purchased.
This guarantee does not cover normal wear and tear. This guarantee does not affect your legal rights. This guarantee applies to the UK only.

8. BATTERY INFORMATION:

PowerCap Active Lite & Powercap Active IP:

Battery Type: Lithium-ion

2 x 3.7V 1900mah

Mark 

Meaning

EN812:1997 ~ A1:2001

European standard for protective Bump Caps.

EN166:1995

European standard for protective EyeWear.

EN166 1 3 B

1 = Optical Quality (high)

3 = Liquid Droplets

B = Medium energy impact against high speed particles.

EN12941:1998+A2:2008

European standard for powered filtering respiratory devices.

9. MARKINGS:

Battery packs should be disposed of 

under local disposal regulations. 

Batteries should not be disposed of in 

general waste bins.

Summary of Contents for POWERCAP ACTIVE

Page 1: ...G DEVICE INCORPORATING A HELMET OR A HOOD CLASS TH1 DEVICE IMPORTANT This manual must be read and fully understood before any product from the PowerCap Range is used This manual must be retained for future reference POWERCAP ACTIVE POWERED RESPIRATOR UNIT ung GB ...

Page 2: ...image Charging the batteries On receipt of the unit run the battery flat and charge for 16 hours to reach maximum capacity Follow on charging cycles should then take 8 hours If the unit is run completely flat or the unit has not been used for a long period it would be advisable to repeat the 8 16hr charge cycle A reduced charging time will reduce the time that PowerCap will operate at its intended...

Page 3: ...ING AND DAILY USE Under normal conditions and assuming regular maintenance the PowerCap motor unit should last for 2 3 years other parts will need replacing as detailed below Prior to use of the PowerCap Active the user must check all components and satisfy themselves that it is suitable for use if any parts need replacing follow instructions below Spare parts are available from the original retai...

Page 4: ...ectacles must also be worn in the normal way within PowerCap Active i e Behind the visor The PowerCap Active airflow will help to prevent fogging of both the Spectacles and the Visor PowerCap Active IP The visor is manufactured of Polycarbonate and has been tested according to EN166 1995 the standard for Personal eye protection As required by European Health and Safety requirements the user is adv...

Reviews: