6. SAFETY PRECAUTIONS:
• PowerCap Active should only be used in situations where EN 12941:TH1 and EN 812:1997 – A1:2001 apply.
• PowerCap Active does not provide protection against the effects of falling or thrown objects, or moving suspended loads.
• PowerCap Active should not be used instead of an Industrial Safety Helmet as specified in EN 397.
• The instructions inside PowerCap Active should be read and understood as well as these instructions before use.
WARNINGS!
• THIS APPARATUS MUST NOT BE WORN WITH THE BLOWER UNIT SWITCHED OFF.
• WHEN SWITCHED OFF A RAPID BUILD UP OF CARBON DIOXIDE AND DEPLETION OF OXYGEN MAY OCCUR.
• WHEN SWITCHED OFF NO RESPIRATORY PROTECTION IS PROVIDED.
• THE APPARATUS SHOULD NOT BE USED IN EXPLOSIVE OR OXYGEN DEFICIENT ATMOSPHERES
• AT HIGH WORK RATES THE PRESSURE IN THE DEVICE MAY BECOME NEGATIVE AT PEAK INHALATION FLOW.
• USING THE APPARATUS IN HIGH WIND VELOCITIES MAY AFFECT FILTERING EFFICIENCY.
PowerCap Active is not designed for use in atmospheres that are immediately hazardous to user hygiene or health, have less than 19.5% oxygen content, contain gases or toxic
substances, or unknown compositions.
• DO NOT use PowerCap Active in an explosive atmosphere. • DO NOT expose PowerCap Active to flames or sparks. • DO NOT use PowerCap Active in confined spaces
or areas of poor ventilation. • DO NOT alter or modify the product in any way. • DO NOT touch any moving part. • DO NOT allow water or other liquids to enter the inside of
the motor housing or battery compartment.
PowerCap Active Lite:
The visor is of lightweight construction and does not provide a high degree of eye protection. In situations where there is any risk to the eyes from
projectiles (for example when strimming) approved type Safety Spectacles must also be worn in the normal way “within PowerCap Active”, i.e. Behind the visor. The PowerCap
Active airflow will help to prevent “fogging” of both the Spectacles and the Visor.
PowerCap Active IP:
The visor is manufactured of Polycarbonate and has been tested according to EN166:1995, the standard for Personal eye-protection.
As required by European Health and Safety requirements, the user is advised that when in contact with the wearers skin, the unit may cause allergic reactions to susceptible
individuals. If this is the case the wearer should leave the hazard area, remove the unit and seek doctor’s advice.
7. GUARANTEE:
PowerCap Active is guaranteed for a period of 12 months from date of purchase against mechanical or electrical defects. The Company undertakes to exchange or repair without
charge, any part to be found defective within this specified period. Alternatively and at its discretion, the Company may replace them.
This guarantee is subject to:- PowerCap Active has been used solely for the purpose for which it is intended. PowerCap Active has not been subject to misuse, accident,
modification or repair.
N.B. In the event of a claim, contact the retailer from which the PowerCap Active was purchased.
This guarantee does not cover normal wear and tear. This guarantee does not affect your legal rights. This guarantee applies to the UK only.
8. BATTERY INFORMATION:
PowerCap Active Lite & Powercap Active IP:
Battery Type: Lithium-ion
2 x 3.7V 1900mah
Mark
Meaning
EN812:1997 ~ A1:2001
European standard for protective Bump Caps.
EN166:1995
European standard for protective EyeWear.
EN166 1 3 B
1 = Optical Quality (high)
3 = Liquid Droplets
B = Medium energy impact against high speed particles.
EN12941:1998+A2:2008
European standard for powered filtering respiratory devices.
9. MARKINGS:
Battery packs should be disposed of
under local disposal regulations.
Batteries should not be disposed of in