The  timers  can  be  programmed  with  the  burners  off  but  it  can  only  be  reduced  with  the 
burner on. 
When the time cycle is complete, the hob will emit an alert sound for 30 seconds. This can 
be turned off by pressing the 

[PT]

 key 

 
Adjusting the Clock 
To  adjust  the  clock  and  especially  after  power  interruptions,  it  is  necessary  to  press 
simultaneously the [

PT]

 and 

[KL]

 keys for 3 seconds. If the hob is on, all the burners will be 

turned off. 
By pressing 

P+ 

or 

P-, 

the digits to the left of the display (hours) and to the left of the display 

(minutes) can be changed. Press the 

PT

 key again to set clocks time. 

 
Unlocking Burners. 
A burner that has been locked out for any reason will have a letter 

b

 showing in its display. 

It  can  be  unlocked  by  simultaneously

  [-A]

  and  [

KL]

  keys  for  two  seconds.  When  this  is 

complete, all of the burners will show

 

“0”

 in their display window which signifies that they are 

switched of and ready to be switched on. 
Note: If the user repeats the unlock procedure more than 5 times in 15 minutes, the display 
will show the error message 

FLT06

 after which the devise cannot be unlocked for a further 

15 minutes. 
 
Keyboard Lock 
The  keyboard  can  be  locked  by  pressing  the 

[KL]

  key  for  at  least  2  seconds.  All  burner 

levels will remain unchanged.  
When the keyboard is locked, it is not possible to alter the gas flow or timer settings because 
the only enabled key is the 

[ON/OFF]

 key. 

To unlock the keyboard, press the [

KL]

 and [

+A]

 keys for 2 seconds. An unlocked keyboard 

has the dots on the displays level switched off. 
 

Calibration and Setting  (Gas Engineers only) 

 
Regulation of minimum gas level of burners  
                 This procedure allows the engineer to reset the predetermined minimum  
                 burner rate i.e. the gas level at first ignition. 
                  Start  the  procedure  by  pressing  keys 

[+]

  on 

burner  B

  and 

[+]

  on 

burner  E

 

simultaneously for 3 seconds with the burners turned off.   
At the start of the process of regulating the burners, the timer display shows 

“MIN”

.  At this 

point,  select  the  desired  burner  to  be  regulated  by  pressing  the 

[P+] 

and  [

P-] 

keys.  The 

appropriate display will activate when it is selected by then pressing the 

PT 

key. 

The burner will start at the minimum level and then it is possible to increase or decrease to a 
new minimum by pressing the

 [P+]

 or 

[P-] 

keys. 

To  regulate  the  intermediate  levels,  increase  the  burner  to  the  desired  level  by  using  the 

[P+] 

and

 [P-] 

keys. 

During the  adjustment  of  minimum  and  intermediate  levels,  the flame  level  displays  shows 
the actual level being regulated whilst the timer display still shows 

MIN

 alternating with a 

decimal number from the modulation table. When the levels are being adjusted, the flashing 
indicators  of  the  display  indicate  that  the  system  has  not  yet  reached  the  stable  condition 
equal to the desired selected level. 
To  confirm  the  capacity  for  each  number,  press  the 

[PT]

  key  to  exit  or  select  a  different 

burner. The selected levels are stored in the system memory during the process. 
Note that it is not possible to alter the flow rate of setting number 7. 
 
 
 
 

 

Summary of Contents for JSI-UK

Page 1: ...3 6 9 Index Packaging Page 2 WEEE Page 2 Safety Page 3 Safety in Use Page 3 Safety of Children Page 4 Care and Maintenance Page 4 Installation Suitability Page 4 Installation Page 5 Replacing the inje...

Page 2: ...turing guarantee period please call 01666 317077 Your JSI appliance comes with a 24 month parts and labour guarantee Please REGISTER your appliance online at wwwwww jsi uk com warranty To get a free a...

Page 3: ...vironmentally friendly Please dispose of all cardboard packaging as soon as possible in an approved disposal collection or depository Any plastic film plastic wrapping and polystyrene must be kept out...

Page 4: ...ns Only approved leak detection spray should be used The appliance should be kept clean at all times and where there are external components these also should be kept clean and regularly maintained an...

Page 5: ...in a dishwasher Pan supports may dis colour over time These can be restored with stove black or similar inert product Installation Suitability Safety regulations prohibit the use of this appliance wit...

Page 6: ...arth the voltage across the detection electrode will drop and cause device lock out as a flame signal will not be able to be detected Gas connection is made using a suitable and approved gas isolation...

Page 7: ...hob to the worktop using the fixing brackets and screws provided Use a hand screw driver only Under no circumstances must an electric screwdriver be used 5 The gas connection is via a male threaded c...

Page 8: ...The burner will be turned off if the and keys are pressed simultaneously If the burner has been on for sufficient time to become hot then the LED will display H when the burner is turned off to signif...

Page 9: ...key is the ON OFF key To unlock the keyboard press the KL and A keys for 2 seconds An unlocked keyboard has the dots on the displays level switched off Calibration and Setting Gas Engineers only Regu...

Page 10: ...onstantly switch on and off the displays by simultaneously pressing the P KL and ON OFF keys for one second but within 5 seconds of turning power on to the appliance This is useful for engineers to ch...

Page 11: ...curred and then the device was switched off Perform burner unlock procedure Resonator anomaly Circuit breakdown Replace device FLt0A All burners in lockout state Ionisation electrode dirty Clean and c...

Page 12: ...contact customer service jsi uk com TECHNICAL SPECIFICATIONS Product Size 90cm 70cmcm Width 860mm 680mmmm Depth 520mm 520mm Height Tray 51mm 51mm Cut Out requirement 90cm 120cm Width 830mm 560mm Depth...