Introduction 

Safety

i

General Safety

Legionella Health & Safety

Correct Use

Water

Note

This manual contains all details necessary for the planning and installation of

the JS HumEvap Mobile 

Plus

Humidifier. In addition commissioning, operating

and maintenance details are included.

The manual is intended for use by engineers and properly trained technical

personnel. Maintenance, servicing or repair work must only be carried out by

suitably skilled and qualified personnel, the customer MUST be responsible

for ensuring their suitability.

No liability will attach to JS Humidifiers plc if any damage, injury or accident is

attributable to inattentive, inappropriate, negligent or incorrect installation and

operation of the machinery whether or not caused deliberately.

Always isolate all electrical and water supplies before commencing any

maintenance.

Please contact JS Humidifiers plc if in any doubt.

Warning!  This humidifier must be installed, operated and maintained in

accordance with this manual.  Failure to do so could result in

contamination that might cause Legionnaires’ disease, which can be

fatal.

Your attention is drawn to the Health and Safety Executive's Approved Code

of Practice (ACoP) and their technical guidance on the prevention and control

of legionellosis in water systems.  If inadequately maintained, water systems,

of which any humidifier is a part, can support the growth of micro-organisms

including the bacterium that causes Legionnaires' disease.  JS Humidifiers plc

has considered all aspects of the design of their humidification systems to

reduce as far as possible the risk of Legionnaires' disease and other similar

conditions, but it is important that users are also aware of their responsibilities

under the ACoP in reducing the risk of legionellosis.  

To prevent the growth of legionella, users are required to:

Carry out a risk assessment of the water system  by a competent 

person, and implement a monitoring and control regime.

Avoid water temperatures that favour the growth of legionella 

(20-45°C);

Avoid water stagnation;

Clean and disinfect the humidification system in accordance with

the ACoP and enclosed instructions;

NEVER leave your HumEvap Mobile 

Plus

out of operation containing water for

more than 24hrs, as it could result in contamination that might cause

Legionnaires’ disease, which can be fatal.  In the event that the humidifier is

turned off for prolonged periods, ensure that the water reservoir and pipe-work

supplying the unit are drained, unless they supply other systems which ensure

a regular renewal of water in the system.  If the unit is found to have been out

of operation for more than 24hrs containing water, water stagnation and

contamination may occur, and the system will require thorough cleaning. 

If you intend to shut the system down for any length of time please contact JS

Humidifiers plc for advice.

The JS HumEvap Mobile Plus Humidifier is only intended for light industrial

direct air humidification and any other or further application is not considered

use for the intended purpose. The manufacturer cannot be made liable for any

damage resulting from incorrect use.

JS Humidifiers systems are designed to be used with mains or softened water.

On no account attempt to introduce any other fluid or chemical into the system

without first consulting JS Humidifiers.

Water supply installation must comply with local regulations.

The water supply to the JS HumEvap Mobile 

Plus

should be free of microbial

contamination and should run at less than 20°C within 2 minutes of turning on

supply

Our policy is one of continuous research and development. We therefore

reserve the right to amend without notice the specifications given in this

document.

Summary of Contents for HumEvap Mobile Plus

Page 1: ...t in contamination that might cause Legionnaires disease which can be fatal WARNING Failure to maintain this humidifier as recommended in this manual will invalidate warranty JS Humidifiers plc Artex...

Page 2: ...oP in reducing the risk of legionellosis To prevent the growth of legionella users are required to Carry out a risk assessment of the water system by a competent person and implement a monitoring and...

Page 3: ...tificates iii Technical Specification iv Principle of Operation v Operating Parameters 1 Unit Positioning and Installation 2 Water Supply 3 Routine Maintenance 4 Maintenance Frequency 5 Replacement of...

Page 4: ...ies Year of Manufacture JS Humidifiers plc Artex Avenue Rustington LITTLEHAMPTON WEST SUSSEX UK BN16 3LN Tel 01903 850200 HumEvap Mobile Plus Humidifier HumEvap Mobile Plus Series 1 00 2006 HumEvap Mo...

Page 5: ...p Mobile Plus to ensure hygienic trouble free operation This water supply MUST be checked regularly to ensure there is no microbiological build up within the building s water supply This is particular...

Page 6: ...alised water in the water reservoir is used to moisten the Evaporator Cassette Air drawn from the room through the Air Care filter travels through the wetted evaporator cassette and absorbs water as i...

Page 7: ...Use to set Fan speed to I II or III To switch the humidifier OFF turn to 0 position The Orange lights will illuminate independantly when the water level in each water tank is low When both lights illu...

Page 8: ...any damage Always use an earthed 230V 50Hz 13 amp power socket Make sure Fan Switch is in OFF 0 position Make sure the power socket is in the OFF position Plug the humidifier power cable into the powe...

Page 9: ...ontrol panel of the humidifier Wipe water off with a dry cloth before starting the humidifier It is essential that clean water is supplied to the unit to ensure hygienic trouble free operation The wat...

Page 10: ...e every 3 months or before if any of the following symptoms occur Odours Heavy soiling or scaling Reduced humidifacation permormance HumEvap Mobile Plus Humidifier Maintenance Routine Maintenance Warn...

Page 11: ...is 100 biodegradable Always wash hands after handling Do not use solvents or other aggressive liquids for cleaning Do not use scouring materials wire brush or scouring cloth etc for cleaning they lea...

Page 12: ...n humidity set point turned to maximum and fan switched to i ii and iii 1 As for daily inspections plus 2 Check operation of the Water Tank low level float switch 3 Check cleanliness of air filter 1 A...

Page 13: ...reduce bacterial contamination of the water This Stick requires replacing every three months to ensure proper bacterial control The Ionic Stick is located in the water reservoir underneath the Evapora...

Page 14: ...tenance Troubleshooting Spares 8 Flush reservoir and place a Disifin tablet into the reservoir and allow to dissolve Check and switch ON Raise Humidity Control level if necessary Turn Fan switch to Hi...

Page 15: ...obile Plus Humidifier Installation Instruction Manual Version 1 00 JS Humidifiers plc June 2006 All rights reserved No parts of this publication may be reproduced without the express consent of the pu...

Reviews: