HumEvap Mobile
Plus
Humidifier
Maintenance
Maintenance Frequency
6
Use and Care
Maintenance Overview and
Frequency
Daily Inspections
Weekly Inspections
Monthly Inspections
Quarterly Inspections
6 Monthly Inspections
Frequent cleaning is necessary to maximise and extend the life of
the humidifier.
To refesh the system, every month, place 1 small Disifin tablet into
the water tank and allow to dissolve.
Always disconnect the unit from the power socket before cleaning
and maintenance.
Regular inspections MUST be carried out by the user to ensure the
unit is operating correctly.
The following represent an inspection regime that may be adopted or
adapted according to the individual circumstances.
1.
Visually check system for leaks
2.
Visually check water level.
3.
Check the the fan runs when humidity set point turned to
maximum, and fan switched to i, ii and iii.
1.
As for daily inspections, plus:
2.
Check operation of the Water Tank low level float
switch.
3.
Check cleanliness of air filter
1.
As for weekly inspections, plus:
2.
To ensure that the system is microbiologically clean, water
samples can be taken.
3.
Remove the Evaporator Cassette and de-scale.
4.
Drain the humidifier Water Reservoir and visually check for
signs of microbial presence, such as a gel-like biofilm (which
might be flaky when dry).
5.
Clean the Water Reservoir if necessary.
6.
Place Disifin purification tablet into the water reservoir, and
allow to dissolve. Run the unit.
1.
As for monthly inspections, plus:
2.
A water sample must be tested for the presence of
legionella.
3.
Replace Ionic Stick
4.
Inspect air filter and replace air filter if necessary
5.
Replace the evaporator cassette
1.
Replace air filter.