25.
2. Press TARE/P.TARE/MOVE key to revolve the system-preset
label format types. (Form0~9)
(Default setting: 0)
Note: When a label printer is used, the file name of the label
format must be FORM (0~9) (such as FORM0, FORM1, FORM2,
and etc.)
3. Press CLEAR/EXIT key to determine and return to normal
counting mode or press TOTAL/PRINT/ENTER key for
determination and move to next.
(VIII) Check alarm type
1. Keep
pressing
TOTAL/PRINT/ENTER
key
in
USER
PROGRAMMING FUNCTION MODE and release until the
following displays appear.
WEIGHT
UNIT WEIGHT
COUNT
0
PASS
82483
Ib kg g
Local Remote
HI OK LO
ADD
check alarm type
check alarm
internal count
2. Press TARE/P.TARE/MOVE key to revolve the system-preset
check alarm types. (Default setting: 0)
0 – Inside type, 1 – Outside type
3. Press CLEAR/EXIT key to determine and return to normal
counting mode or press TOTAL/PRINT/ENTER key for
determination and move to next.
★
Inside type
The alarm sounds beeps only when either total weight or total
count falls inside the set range.
S.W
lack
U.W
lack
Battery
low
Stable Zero NET