3-6
3
1) Processing cables
When you directly connect with the ship's power supply without using the optional
rectifier, measure the voltage between the hull's earth and the positive side of ship's
power supply, and the hull's earth and the negative side of this. And check voltage of
50 volts or more is not required.
If voltage of 50 volts or more is required, take the measures which do not require 50
volts or more between the above mentioned terminals.
Connection without taking the measures causes system failure or accident.
2) Connecting the cable to the radar process unit
Connect the CFQ-6911 connector to the connector for which "POWER" is engraved at the rear of the
radar process unit cabinet. Turn the plug attached to the connector until it cannot be turned any further.
The CFQ-5436 is connected here.
NMEA
AUX
VIDEO
AIS
NMEA
GYRO
COMPASS
GPS
KEY BOARD
E
POWER
SCANNER
F3
F1
F2
Cable process method
1. Crimp three black cables
together.
2. Crimp three red cables together
in the same way.
3. Crimp the shielding cable.
4. Install the red cables on the +
side of the ship's power supply,
the black cables on the - side of
the ship's power supply, and
the shielding cable in the hull's
earth.
Summary of Contents for JMA-5212-4
Page 2: ......
Page 6: ...ġ ...
Page 8: ...ġ ...
Page 9: ...SECTION 1 OVERVIEW ...
Page 20: ...2 9 2 3 CONNECTING THE INSTALLATION CABLE NKE 2103 ...
Page 21: ...ġ 2 10 2 ...
Page 22: ...2 11 2 4 CONNECTING THE INSTALLATION CABLE NKE 2254 ...
Page 23: ...ġ 2 12 2 ...
Page 24: ...2 13 ...
Page 139: ...APPENDIX ...
Page 140: ...Fig 1 NKE 2103 4 Outside Drawing ...
Page 141: ...Fig 2 NKE 2103 6 Outside Drawing ...
Page 142: ...Fig 3 NKE 2254 7 Outside Drawing ...
Page 143: ...Fig 4 NKE 2254 9 Outside Drawing ...
Page 144: ...Fig 5 NWZ 164 Outside Drawing ...
Page 145: ...Fig 6 NDC 1460 Outside Drawing ...
Page 146: ...Fig 7 NCE 7699A Outside Drawing ...
Page 147: ...Fig 8 NBA 5111 Outside Drawing ...
Page 149: ...Fig 10 GENERAL SYSTEM DIAGRAM OF RADAR TYPE JMA 5222 7 9 ...