Chapter 1 INSTALLATION
16
■
Others
■
The design of the mounting platform for the scanner should take into account the
vibration requirements defined by IEC 60945.
Vibration
Frequency
2 to 13.2 Hz
13.2 Hz to 100 Hz
Amplitude
+/-1 mm +/-10 %
Acceleration
7m/s
2
constant
■
All installations should facilitate protection of equipment, including cabling, from
damage.
■
The cables should be kept as short as possible to minimize attenuation of the signal.
■
Crossing of cables should be done at right angles(90°) to minimize magnetic field
coupling.
■
Install the radar cable as far as from the cables of other radio equipment in order to
prevent other radio equipment from interfering with the radar operations. Especially
inter-wiring cables between scanner unit and display unit of the radar should not be
run parallel with the cables of other radio equipment.
■
Cable should not be exposed sharp bends.
■
Ensure that the equipment is grounded.
■
Maintain a flat level surface on which to install the scanner.
■
Use sufficiently thick steel material and reinforcement material for the scanner's
installation surface (mount base) to reduce vibration and impact. Keep the mount
base flat and smooth.
■
If there is a partial gap between the mount base and the scanner chassis's legs, work
on the installation surface so that it becomes flat and smooth, or make adjustments
by inserting metal shims.
If a gap exists and the scanner is tightly clamped, the chassis will distort and become
damaged by vibration.
■
Avoid using vibration-proof rubber and resin
■
Do not insert an elastic body, such as vibration-proof rubber or resin, between the
mount base and the scanner chassis' legs. If rubber or resin is inserted, the amplitude
of vibration increases, resulting in the possibility of damage to the scanner.
Furthermore, if installation bolts become loose due to deterioration of rubber or resin,
the scanner may be damaged or fall from its mount
Summary of Contents for JMA-1032
Page 1: ...JMA 1030Series MARINE RADAR EQUIPMENT INSTRUCTION MANUAL ...
Page 2: ......
Page 18: ...xvi WARNING LABEL MOUNTING POINT NKE 2044 SCANNER UNIT View from cable inlet side ...
Page 22: ......
Page 28: ......
Page 34: ......
Page 37: ...Chapter 1 INSTALLATION 3 1 2 3 DIMENSIONAL DRAWING OF DISPLAY MOUNTING ...
Page 38: ...Chapter 1 INSTALLATION 4 ...
Page 40: ...Chapter 1 INSTALLATION 6 Disktop Mounting Template ...
Page 42: ...Chapter 1 INSTALLATION 8 Flush Mounting Template ...
Page 43: ...Chapter 1 INSTALLATION 9 CEILING INSTALLATION Option fixation tool ...
Page 52: ...Chapter 1 INSTALLATION 18 NKE 2044 2 FT SCANNER Fig 1 3 6 3 Fig 1 3 6 4 ...
Page 56: ...Chapter 1 INSTALLATION 22 Fig 1 4 1 3 ...
Page 57: ...Chapter 1 INSTALLATION 23 ...
Page 60: ...Chapter 1 INSTALLATION 26 Fig 1 4 2 3 ...
Page 61: ...Chapter 1 INSTALLATION 27 ...
Page 62: ...Chapter 1 INSTALLATION 28 Fig 1 4 2 4 Clamp whole cable Connect cable s mesh wire as Ground ...