8-13
8.4 Connection Box (NQE-5183 option)
8.4.1 Environmental condition
(1) Operating temperature
: -15
°
C to +55
°
C (IEC 60945)
8.4.2 External interfaces (connected with NCM-983)
(1) Sensor data input ports SENSOR1 / SENSOR2/ SENSOR3
Four input ports meet the requirements of IEC 61162-1.
(2) Gyrocompass data input
Current loop 1 communication port (multiple use as SENSOR3)
(3) GNSS differential correction data input port SENSOR4
One input port meet the requirement of ITU-R M.823-2 on TTL level
(4) External display equipment communication ports AUX1 / AUX2 / AUX3
Three communication ports meet the requirements of IEC 61162-2
(5) Long range communication port AUX3
One communication port meets the requirements of IEC 61162-2
(6) Relay terminals ALR
One port for external alarm device
8.5 AC Power Supply Unit (NBD-577C option)
(1) Input voltage
: 100 - 120 / 200 - 240 VAC ±10%, 50/60Hz Single phase
: 24VDC (backup power supply)
(2) Output voltage
: Nominal 24VDC, 19 - 35VDC
Summary of Contents for JHS-183
Page 2: ......
Page 7: ...v External Views NTE 183 AIS Transponder NCM 983 AIS Controller ...
Page 8: ...vi Optional equipment NQE 5183 Connection Box NBD 577C Power Supply Unit ...
Page 12: ...x ...
Page 16: ...1 4 1 4 Outline Outline Drawing of NTE 183 AIS Transponder Unit mm Mass approx 2 6kg ...
Page 17: ...1 5 Outline Drawing of NCM 983 AIS Controller Unit mm Mass approx 2 1 kg ...
Page 18: ...1 6 Outline Drawing of NQE 5183 Connection Box Unit mm Mass approx 2 5 kg ...
Page 19: ...1 7 Outline Drawing of NBD 577C Power Supply Unit Unit mm Mass approx 5 2 kg ...
Page 22: ...2 2 ...
Page 26: ...4 2 ...
Page 92: ...5 66 ...
Page 98: ......
Page 110: ...7 2 ...
Page 124: ......
Page 126: ......
Page 127: ......