![JRC JCY-1850 - Instruction Manual Download Page 55](http://html1.mh-extra.com/html/jrc/jcy-1850/jcy-1850_instruction-manual_2028223055.webp)
3. Maintenance and Inspection
41
Symptom
Causes
Actions to be taken
Faulty wiring between the
Recording
Control Unit
and the
Protective Capsule
Unit
Check the
Connection Box
.
ERROR CODE:
“20__”
lights up.
Fault in the
Recording Control Unit
Fault in the
Protective Capsule Unit
Reboot the
Recording Control Unit
,
and see if the symptom persists. If
so, contact us.
ERROR CODE:
“21__”
lights up.
Fault in recording the data in the
Protective Capsule Unit
The
BER ERROR
could occur
temporarily.
The error is canceled in less than 2
days automatically.
If the error is not canceled after 2
days, contact us.
Fault in sensors
Check the sensor equipment shown
by error code.
Faulty wiring between the
Recording
Control Unit
and the sensors
Check the wiring between the
Recording Control Unit
and the
sensors.
ERROR CODE:
“60**”
lights up.
Fault in the
Recording Control Unit
Reboot the
Recording Control Unit
.
See if the symptom persists. If so,
contact us.
ERROR CODE:
“61**”
lights up.
Fault on setting up the
Main Control
Board
Reboot the
Recording Control Unit
,
and see if the symptom persists. If
so, contact us.
Fault in the
Audio Recording Board
Fault in the
Microphone Unit
Check the wiring between the
Microphone Unit
and the
Recording
Control Unit
.
ERROR CODE:
“5*__”
lights up.
Alarm was raised due to a large noise. Reboot the
Recording Control Unit
in
noise-free environment.
Power failure
Check the power supply in the
Recording Control Unit
.
No power is supplied from the
switchboard.
Check the switchboard.
ERROR CODE:
“10__”
lights up.
The fuse for the AC power source is
blown.
Check the fuse for the AC power
source and, if it is blown, replace it
with a spare fuse.
ERROR CODE:
“11__”
lights up.
The fan of
Power Supply Unit
is not
working.
Contact us.
ERROR CODE:
“30__”
/
“35__”
/
“36__”
/
“37__”
/
“38__”
light up.
Fault in the
Main Control Board
Reboot
the
Recording Control Unit
,
and see if the symptom persists. If
so, contact us.
ERROR CODE:
“33__”
lights up.
GPS is faulty or setting error on the
Main Control Board
Check the GPS.
If the GPS is error-free, contact us.
ERROR CODE:
“34__”
lights up.
An internal battery for a Real Time
Clock IC has run out of the life.
Contact us for exchanging the
battery.
Summary of Contents for JCY-1850 -
Page 1: ...SIMPLIFIED VOYAGE DATA RECORDER INSTRUCTION MANUAL CODE 7ZPJD0389A ...
Page 2: ......
Page 3: ......
Page 4: ......
Page 60: ...4 After sales service 46 This page is intentionally left blank ...
Page 64: ...5 Outline Drawings 50 5 4 Connection Box NQE 3163 The Outline Drawing of the Connection Box ...
Page 65: ...5 Outline Drawings 51 5 5 Microphone Unit NVT 161 The Outline Drawing of the Microphone Unit ...
Page 68: ...5 Outline Drawings 54 This page is intentionally left blank ...