The DiaDENS unit may be applied for treatment of patients any age from newly born 

children to elderly people. 

Indications:

— acute and chronic pain syndromes; 

— injuries;

— treatment of functional disorders in case of diseases of the respiratory apparatus, ENT 

organs, the cardiovascular, musculoskeletal, nervous, endocrine and urinogenital 

systems, the eyes and the skin; 

— rehabilitation after diseases, surgery and injuries; 

— enhancement of adaptability of the body in case of exposure to adverse factors 

and  in  the  conditions  of  hard  physical  and  mental  work,  in  case  of  physical  and 

intellectual  overstress,  chronic  fatigue  syndrome,  difficulties  waking  up  in  the 

morning  and  sleepiness  during  the  day,  in  case  of  dyskoimesis  in  the  evening 

Summary of Contents for DiaDENS-T

Page 1: ...64 DiaDENS T Pro 2010 OPERATIONS Contact JPA support jpastar com www jpastar com 888 708 9457 FOR INFORMATION MORE MANUAL...

Page 2: ...RC ART LLC Ekaterinburg Russia Operating Manual DiaDENS T RC ART 09 1 03 72 04 RE Russia EU all USA Canada...

Page 3: ...ntees 104 10 Manufacturer s address 106 Part 2 Application Instruction 1 General information 108 2 Indications and contraindications 109 3 Treatment conditions 113 4 Electrostimulation intensity 115 5...

Page 4: ...67 Thank you for using the DiaDENS T unit In order to make the usage of the unit effective and safe please read carefully all section of this manual...

Page 5: ...68...

Page 6: ...69 PART 1 Technical Passport...

Page 7: ...al is important for your safety and for correct application and maintenance of the unit The unit is safe in operation as it uses the low voltage power supply isolated from the working part of the unit...

Page 8: ...gh frequency electric device Simultaneous use of the unit and other electric devices may cause burns and possible damage of the unit Operation in the vicinity of short wave or microwave equipment may...

Page 9: ...nit to direct sunrays at a high ambient temperature over 25 o C This may cause failure of the indicator on the unit or destroy its batteries The unit is not waterproof Protect is from moisture All mai...

Page 10: ...50 to 40 0 relative air humidity 30 to 93 atmospheric pressure 70 to 106 kPa 525 to 795 mm Hg Operating conditions temperature 10 to 35 0 relative air humidity 30 to 93 atmospheric pressure 70 to 106...

Page 11: ...of electric and electronic equipment Warning The unit contains precious materials that may be used repeatedly after disposal with consideration of the environmental protection regulations Theymustbes...

Page 12: ...e individual treatment programs The DiaDENS T unit is designed for medical and preventive treatment facilities and individual application in accordance with the instructions of the attending physician...

Page 13: ...76 3 UNIT DESCRIPTION Picture 1 Arrangement of the unit Front keyboard case display...

Page 14: ...l number under the batteries inside the battery compartment of the unit Make sure not to remove it and not to delete the serial number as it results in loss of warranty for the unit Warning Theconnect...

Page 15: ...78 Picture 3 Position and function of buttons on the keyboard Stimulation power step up Stimulationpower step down ON OFF timer control operation mode change...

Page 16: ...gital indication Stimulation power graphic indication Time or measurement results indication Stimulation frequency setting Screening mode Test phase indication MED mode Battery charge indication Sound...

Page 17: ...uld be positioned comfortably seated or lying After the procedure it is recommended to remain relaxed for 10 15 minutes 4 2 Switching on the unit Press the button the unit should turn on and switch to...

Page 18: ...r decrease of the stimulation power press and hold down the button When the desired power level is reached release the button The stimulation power level setting is shown in the left top corner of the...

Page 19: ...and the Timer Activated indication is shown on the display Next pressure of the button after a 20 minute interval switches off theTimer function the Timer Activated indication on the display disappear...

Page 20: ...no picture 4 7 Forced Therapy Function In the Forced Therapy mode the unit can operate in the therapy modes irrespective of the presence and the quality of the contact of the electrodes with the skin...

Page 21: ...keyboard buttons are not used Do not leave the unit with the Forced Therapy function activated as it will cause discharge of the battery before the indicated time 4 8 Switching off the unit Press the...

Page 22: ...oom temperature for at least 2 hours 4 9 1 Open the consumer package and take out the unit Warning Before the first use wipe the electrodes with a disinfectant solution for example 3 hydrogen peroxide...

Page 23: ...ion If required connect one of the detachable electrodes to the respective plug picture 1 specified in Annex 2 In case of a small skin contact area or in case of a dry skin turn on the Forced Therapy...

Page 24: ...it reaches the desired level minimum comfortable or maximum The stimulation time will start Warning It is not recommended to carry out the procedure at an intolerable power level If the Timer functio...

Page 25: ...ontact with the skin 4 10 8 After completion of the procedure switch on the unit and clean the electrodes with soft pile free tissue moistened with a standard disinfectant such as 3 hydrogen peroxide...

Page 26: ...contains the following items Name Number pieces DiaDENS T unit 1 Operation manual combined with the application instructions and technical passport 1 Type LR6 AA battery 2 Consumer packaging 1 The num...

Page 27: ...grated electrode and the detachable electrodes before and after use The lack of adequate cleaning may cause allergic reactions or skin infection especially in case of use of the unit by several patien...

Page 28: ...do this open the battery compartment as shown in picture 5 remove the used batteries install new batteries making sure that the polarity is correct close the battery compartment cover on the unit Use...

Page 29: ...92 Picture 5 DiaDENS unit battery replacement procedure 1 Remove the battery compart ment cover 3 Close the battery compart ment cover 2 Install new batter ies making sure that the polarity is correct...

Page 30: ...roblem Possible cause Remedy The unit does not turn on when the button is pressed No batteries Install new batteries see Maintenance and Battery Replacement Procedure The unit does not turn on when th...

Page 31: ...tery voltage less than 2 1 V Replace batteries see Battery Replacement Procedure The unit does not switch to the stimulation mode when the integrated electrodes are in contact with the skin surface no...

Page 32: ...umption of batteries Poor quality batteries Use good quality batteries alkaline batteries are recommended or rechargeable batteries of the corresponding type and size with the voltage not exceeding 1...

Page 33: ...the electrodes and the skin surface and when its controls have not been used for more than 2 minutes A detachable electrode is connected to the unit Turn off the unused detachable electrode Forced Th...

Page 34: ...ax 10 A 8 2 Weight without batteries max 300 g 8 3 Dimensions max 135x51x46 mm 8 4 The unit turns off automatically if not used for more than 3 min except in the Forced Therapy mode 8 5 Operating para...

Page 35: ...in the positive part max 40 V amplitude in the negative part max 10 V 8 6 Relation between the impulse waveform and the load resistance at the medium and maximum power level Load resistance Power lev...

Page 36: ...99 200 Ohm 15 V 20 20 V 20 500 Ohm 30 20 Epulse 155 uJ 40 V 20 Epulse 299 uJ...

Page 37: ...100 1 kOhm 60 V 20 75 V 20 2 kOhm 95 V 20 140 V 20...

Page 38: ...ctive current Ieff for load resistance 500 Ohm Mode Power level Half Power level Full 20 Hz Ieff 2 5 mA Ieff 3 5 mA 60 Hz Ieff 4 5 mA Ieff 6 0 mA 77 Hz Ieff 5 0 mA Ieff 6 8 mA 140 Hz Ieff 6 6 mA Ieff...

Page 39: ...nditions Acceptable level IEC 61000 4 6 3 Vrms 150 kHz to 80 MHz 3 Vrms IEC 61000 4 3 3 V m 80 MHz to 2 5 GHz 3 V m 8 10 Electromagnetic field resistance Test Test level Conformity level Conditions of...

Page 40: ...determination of the required distance between the DiaDENS T stimulation unit and radio frequency radiating equipment Declared maximum output power of the transmitter P W Radiation frequency and the d...

Page 41: ...may be much longer than the officially established one 9 3 Warranty operation term 24 months of the date of sale 9 4 The Seller Manufacturer or the organization acting on behalf of the Seller Manufact...

Page 42: ...unit or its defect during the effective term of the warranty and if the owner discovers that certain components are missing the owner of the unit shall send to the manufacturer or his representative...

Page 43: ...LLC Academician Postovsky St 15 Ekaterinburg 620146 Russia Tel 7 343 267 23 30 http www denascorp ru e mail corp denascorp ru Official Representative in the European Union DENAS CZ s r o Na Vyhlede 3...

Page 44: ...107 PART 2 Application Instructions...

Page 45: ...es show that electroneurostimulation DENS is based on multi level reflectory and neurochemical reactions that trigger a cascade of regulatory and adaptive mechanisms of the body which leads to elimina...

Page 46: ...ENT organs the cardiovascular musculoskeletal nervous endocrine and urinogenital systems the eyes and the skin rehabilitation after diseases surgery and injuries enhancement of adaptability of the bod...

Page 47: ...ned therapeutic effect of individual procedures also creates an after effect of the treatment course that continues after its completion and the long term results are in some cases even more favourabl...

Page 48: ...ck of positive changes or aggravation of the patient s condition consult the attending physician Contraindications Absolute idiosyncrasy to electric current an implanted heart pacesetter Relative stat...

Page 49: ...narcotic excitement Warning If you have any of the above listed contraindications consult your physician before using this device Warning In case of idiosyncrasy if you feel worse or the pain increase...

Page 50: ...onditions The procedures can be performed without attendance of a physician or a nurse or by an operator who will carry out the treatment in the zones and points that the patient cannot reach without...

Page 51: ...Units Warning After each procedure clean the electrodes with a standard disinfectant solution such as 3 hydrogen peroxide solution The unit should be stored with dry electrodes Manual on dynamic elec...

Page 52: ...used when intensive stimulation is not recommended that is for patients with low intensity pain In case of cardiovascular diseases arterial hypertension arterial hypotension and vegeto vascular dysto...

Page 53: ...the electrodes This level is used for the treatment of a strongly manifested pain syndrome Warning At different stages of treatment the electrostimulation power level can be increased and decreased as...

Page 54: ...labiletreatmentmethod move the built in electrodes smoothly around the treated area so that they remain in constant contact with the body surface at the speed of 0 5 to 3 cm sec You may make linear sp...

Page 55: ...lowing response the complaint is fully eliminated the patient feels considerably better bright redness of the skin or a feeling of warmth in the area under the electrodes The following frequencies are...

Page 56: ...up to 1 1 5 hours and more Indications functional disorders and pain syndromes in case of internal diseases and during the post surgery period c therapeutic frequency 20 Hz is used in the area of dir...

Page 57: ...oncentrate and focus attention for non specific preventive treatment of catarrhal diseases during epidemics Treatment is carried out in the hand area he gu zone as shown in picture 6 The procedure sho...

Page 58: ...de can be used one time during each procedure It is recommended to deliver a course of 10 to 14 procedures The unit may be moved to the next area after the mode time is over sound alarm or indication...

Page 59: ...122 Picture 6 Stimulation on the hand he gu he gu zone...

Page 60: ...the electrodes of the unit in the selected area direct projection of the complaint Warning During operation of the unit in the Screening mode the electrodes should be placed on the skin in the stable...

Page 61: ...LT 8 Record the value obtained Place the unit in the next skin area within the selected zone Repeat the manipulation on the whole area The skin areas with the maximum LT significantly different from t...

Page 62: ...odynia or on the skin in the area around the affected joints in case of pain in the knee joints is one of the key simple and rather effective methods of treatment area selection To enhance the treatme...

Page 63: ...or children aged 0 to 12 months 5 10 minutes for children aged 12 to 36 months 10 15 minutes for children aged 3 to 5 years 15 20 minutes for children aged 5 to 12 years 20 25 minutes for children old...

Page 64: ...OOO RC ART Ekaterinburg Russland Bedienungsanleitung DiaDENS T RC ART 09 1 03 72 04 RE Russia EU all USA Canada...

Page 65: ...190 DiaDENS T OPERATIONS Russian Languages German English FOR Contact support jpastar com 888 www jpastar com 708 9457 JPA INFORMATION MORE APPENDIX MANUAL Pro 2010...

Page 66: ...191 1 ANNEX 1 Brief reference atlas on the application of DENS for treatment of common diseases ANLAGE 1 Kurzes DENS Atlas Nachschlagewerk zu h ufig auftretenden Krankheiten...

Page 67: ...2 77 10 ACUTE RESPIRATORY AND ENT DISEASES AKUTE ATEMWEGSKRANKHEITEN UND ERKRANKUNGEN DES HALS NASEN OHREN BEREICHES Nose and the area around it 77 Hz 10 minutes Nasen Bereich Frequenz 77 Hz 10 Minute...

Page 68: ...10 15 Submaxillary area 77 Hz 10 minutes Area on the posterior surface of the back around the neck 10 Hz 10 15 minutes Submandibulare Zone Frequenz 77 Hz 10 Minuten Hals Nacken Bereich Frequenz 10 Hz...

Page 69: ...IS BRONCHITIS PNEUMONIE ASTHMA BRONCHIALE Anterior projection of the lungs 77 Hz 10 minutes Posterior projection of the lungs 77 Hz 10 minutes Projektionszone der Lunge von vorn Frequenz 77 Hz 10 Minu...

Page 70: ...195 77 10 20 10 15 Submaxillary area 77 Hz 10 minutes Submandibulare Zone Frequenz 77 Hz 10 Minuten Submandibulare Zone Frequenz 20 Hz 10 15 Minuten Segmental area 10 Hz 10 15 minutes...

Page 71: ...nd the neck in case of diseases of the arm joints 20 Hz 7 10 minutes Lumbosacral area in case of diseases of the leg joints 20 Hz 7 10 minutes Hals Nacken Bereich bei Erkrankungen der Armgelenke Frequ...

Page 72: ...g pain 140 or 200 Hz until the pain subsides Symmetrical zone marked in green 20 Hz 10 15 minutes Zone der direkten Projektion des gesch digten Gelenks rot markiert 77 Hz bei starken Schmerzen 140 ode...

Page 73: ...cken 77 140 200 Direct projection of pain in the neck or in the back 77 Hz in case of strong pain 140 or 200 Hz until the pain subsides Direkte Schmerzprojektion an Hals oder R cken 77 Hz bei starken...

Page 74: ...7 10 Area on the posterior surface of the back around the neck 10 Hz 7 10 minutes Lumbosacral area 10 Hz 7 10 minutes Hals Nacken Bereich Frequenz 10 Hz 7 10 Minuten Lumbosakralbereich Frequenz 10 Hz...

Page 75: ...200 HEADACHE Kopfsch merzen 77 5 7 20 5 10 Area around the second cervical vertebra 77 Hz 5 7 minutes 20 Hz 5 10 minutes Zone des zweiten Halswirbels 77 Hz 5 7 Minuten Frequenz 20 Hz 5 10 Minuten...

Page 76: ...201 10 7 10 Area on the posterior surface of the back around the neck 10 Hz 7 10 minutes Hals Nacken Bereich Frequenz 10 Hz 7 10 Minuten...

Page 77: ...TOOTHACHE Zahnschmerzen 200 77 Projection of the affected tooth 200 and 77 Hz until the condition improves Projektionszone des erkrankten Zahnes Frequenz 200 und 77 Hz bis zur Verbesserung des Befind...

Page 78: ...203 10 10 15 Area on the posterior surface of the back around the neck 10 Hz 10 15 minutes Hals Nacken Bereich Frequenz 10 Hz 10 15 Minuten...

Page 79: ...204 WOUNDS AND BURNS WUNDEN UND BRANDVER LETZUNGEN 140 77 15 Area around the wound burn 140 and 77 Hz 15 minutes Zone rund um die Wunde Brandverletzung Frequenz 140 und 77 Hz 15 Minuten...

Page 80: ...njury of the upper extremities lumbosacral area in case of injury of the lower extremities 10 Hz 10 15 minutes Hals Nacken Bereich bei Verletzungen der oberen Extremit ten Bereich der lumbosakralen Zo...

Page 81: ...206 20 10 15 CONSTIPATION AND ABDOMINAL SWELLING VERSTOPFUNG UND BL HBAUCH Segmental area 20 Hz 10 15 minutes Segmentzonenbereich Frequenz 20 Hz 10 15 Minuten...

Page 82: ...207 77 15 Projection of the liver and the intestines 77 Hz 15 minutes Projektionszone der Leber und des Darmtraktes Frequenz 77 Hz 15 Minuten...

Page 83: ...208 DIARRHEA DURCHFALL 20 10 15 Segmental area 20 Hz 10 15 minutes Segmentzonenbereich Frequenz 20 Hz 10 15 Minuten...

Page 84: ...209 77 15 Projection of the liver and the intestines 77 Hz 15 minutes Projektionszone der Leber und des Darmtraktes Frequenz 77 Hz 15 Minuten...

Page 85: ...210...

Page 86: ...211 2 ANNEX 2 Accessories used ANLAGE 2 Einsetzbares Zubeh r...

Page 87: ...on invasive therapy of the pain area lesion foci and reflexogenous areas with undamaged skin Satz Au enelektroden DENS Applikator Zur therapeutischen nichtinvasiven Behandlung im Bereich des Schmerzes...

Page 88: ...3 Therapeutic detachable massage electrodes Designed for stimulation in the area of the pain lesion foci reflexogenous areas and acupuncture points of the body Therapeutische Au enelektroden f r Massa...

Page 89: ...ive points around the eyes in the paraorbital area using the dynamic electroneurostimulation method Paraorbitale Au enelektrode DENS Brille Zur prophylaktischen und therapeutischen nichtinvasiven Beha...

Page 90: ...Zur therapeutischen Behandlung biologisch aktiver Punkte mittels dynamischer Elektroneurostimulation Detachable therapeutic electrode Designed for therapy of biologically active points using the dynam...