background image

46

We  recommend  to  alternate  it  with  the 
Nourishment  program  your  face  has  a  tendency 
to become edematic. 
To conduct treatment in this mode, use the tissue 
mask moistened with a saline solution, for example 
in the physiological solution (0,9 % NaCl solution) 
or 1 % Karlsbad salt solution.
 

5.7. Mode combination during the procedure

We  recommend  to  use  one  of  the  unit  modes 
during  the  procedure.  It  needs  to  be  decided 
separately  in  each  case  whether  it  makes  sense 
to  use  two  modes  in  consequence  during  one 
procedure,  depending  on  the  treatment  effect 
and individual sensitivity of each patient.

Please  adhere  to  the  recommended 
treatment schemes. If you apply the unit too 
frequently, this may cause skin irritation. 

5.8. Preparation of the unit for the procedure 

Before  using  the  unit,  make  sure  that  there  are 
no impact marks on its case and the liquid crystal 
display of the unit is not damaged. Make sure that 

there are no traces of foreign materials or signs of 
damage  on  the  cuff  electrode  and  on  the  mask 
electrode. 

Do not use the unit if it is damaged.
Do  not  use  the  mask  electrode  if  the 
conducting  layer  is  damaged  (change  of 
colour or mechanical destruction).

5.8.1.

  If  there  are  no  batteries  in  the  battery 

compartment, install the batteries. When installing 
the batteries, make sure you observe the correct 
polarity.

5.8.2. 

Before the first use, wash the cuff electrode 

and  the  mask  electrode  with  soap  solution. 
Wash off the remaining soap with running water. 
Remove the remaining moisture with dry tissue.

5.8.3.

 Put the mask electrode in front of you with 

the decorative side down. 

5.8.4.

 Connect the cable to the mask electrode. 

5.8.5.

 Slightly moisten the skin on the back surface 

of your forearm. Fix the unit on your arm, making 
sure that it fits tightly on your moistened skin. 

Summary of Contents for DiaDENS Cosmo

Page 1: ...30 DiaDENS Cosmo FOR Contact support jpastar com 888 www jpastar com 709 9457 JPA INFORMATION MORE Instrument Cosmetology In Home The Manual Operations...

Page 2: ...RC ART LLC Skin Care Unit DiaDENS Cosmo Operating Manual RC ART 14 0 03 71 03 RE Russia EU all USA Canada...

Page 3: ...5 Operating instructions 44 6 Box contents 50 7 Maintenance and battery replacement 51 8 Troubleshooting 52 9 Technical information 53 10 Manufacturer s warranties 56 11 Manufacturer s address 57 12...

Page 4: ...33 To ensure effective and safe usage of the unit please read carefully all sections of this manual Thank you for purchasing the DiaDENS Cosmo unit...

Page 5: ...the information marked with this sign This information is important for ensuring safe and effective use of the unit The information contained in this Operating Manual is important for your safety and...

Page 6: ...ion regulations Operating conditions temperature 10 to 35 0 relative air humidity 30 to 93 atmospheric pressure 70 to 106 kPa 525 to 795 mm Hg Warning If the unit was stored at the ambient temperature...

Page 7: ...e of which may restrict or preclude from the application of the unit for medical reasons They include an implanted heart pacesetter or other implanted electronic devices idiosyncrasy to electric curre...

Page 8: ...and therefore skin nutrition It becomes dry and less elastic changes its colour and becomes wrinkled While we cannot stop the pace of time modern cosmetology provides every opportunity to protect our...

Page 9: ...ed use of the device 3 The DiaDENS Cosmo unit is designed for cosmetological treatment of the facial skin The treatment does not require any special conditions The unit can be used at home or at beaut...

Page 10: ...39 unit description 4 Picture 1 Arrangement of the unit Front...

Page 11: ...40 Picture 2 Arrangement of the unit Back with the conducting cuff conducting layer...

Page 12: ...41 Cable input Unit with the cable connected Picture 3 Arrangement of the unit Cable input and unit with the cable connected Picture 4 Arrangement of the unit Battery compartment Battery compartment...

Page 13: ...electrode connected Do not connect any detachable electrodes other than the mask electrode designed for use with DiaDENS Cosmo Picture 5 Mask electrode Do not connect the mask electrode to any type o...

Page 14: ...eyboard Treatment power step up Unit on off Operation mode change Nourishment Lymph drainage Start Pause starts and stops operation in the selected mode Treatment power step down Liquid crystal displa...

Page 15: ...n a small skin area close to the elbow and let it dry 2 if skin redness is evident in the area where the drop was applied within 1 2 hours do not use this beauty mask for treatment 5 3 Skin preparatio...

Page 16: ...es in the human body an insignificant number of people maximum 2 3 show insufficient response or complete lack of response to the treatment without any negative consequences Depending on your skin typ...

Page 17: ...e that there are no impact marks on its case and the liquid crystal display of the unit is not damaged Make sure that there are no traces of foreign materials or signs of damage on the cuff electrode...

Page 18: ...the beauty mask with any solution not recommended for use with DiaDENS Cosmo Warning Do not use any masks other than those recommended for use with the unit Other masks were not tested for compatibili...

Page 19: ...erent electric stimulation sensitivity and some people may not feel anything at the maximum power This is not a defect of the unit and does not decrease effect of the procedure If you have any unpleas...

Page 20: ...Store the mask electrode dry Make sure that the cosmetic solution does not dry on the mask electrode Clean the mask electrode immediately after each procedure Do not continue using the mask electrode...

Page 21: ...ing and cleaning DiaDENS Cosmo beauty mask 6 Cuff extender 1 Operating manual 1 Battery 2 Consumer package 1 The box may additionally contain test samples of other beauty mask tested by the manufactur...

Page 22: ...eral patients Use soap and running water for cleaning 7 2 If the unit will not be used for a long period of time more than 3 days remove the batteries from the battery compartment This will prevent th...

Page 23: ...nds an alarm and switches off automatically contact a representative of the company see Section 11 The unit does not start treatment no skin contact symbol 1 Make sure that the cuff electrode is in ti...

Page 24: ...for more than 3 min 9 5 Stimulation impulse frequency in the Nourishment mode 100 30 Hz 9 6 Stimulation impulse frequency in the Lymph mode 100 30 Hz and 50 15 Hz 9 7 Treatment duration 15 1 min 9 8 R...

Page 25: ...54 200 Ohm 0 5 V 20 2 5 V 20 500 Ohm 0 77 V 20 Epulse 0 92 uJ 4 V 20 Epulse 25 uJ 1 kOhm 0 9 V 20 4 7 V 20...

Page 26: ...55 2 kOhm 1 1 V 20 5 3 V 20 9 9 Effective current Ieff for load resistance 500 Ohm Mode Power level Min Power level Full Lymph drainage Ieff 0 43 mA Ieff 2 22 mA...

Page 27: ...it shall not be liable for defects if they have occurred after the transfer of the unit to the user due to 1 failure of the user to observe the transportation storage maintenance and operation rules...

Page 28: ...57 manufacturer s address 11 RC ART LLC Academika Postovskogo St 15 Ekaterinburg 620146 Russia Tel 7 343 267 23 30 http www denascorp ru e mail corp denascorp ru...

Page 29: ...any questions regarding the operation of the unit purchase of the consumables etc you may contact Distributor contacts 12 Full name Telephone Website www denascorp ru Telephone 8 800 200 1919 free ca...

Page 30: ...OOO RC ART Ger t zur kosmetologischen Behandlung DiaDENS Cosmo Bedienungsanleitung RC ART 14 0 03 71 03 RE Russia EU all USA Canada...

Reviews: