background image

21

9.7.4 Advanced Menu Instruction

Menu

Long press "PROG" 2 seconds

to enter into base menu.

Option

Press “+”(up) or “-”(down) to select;

Press “SET” to confirm.

Default/Attention

Travel time adjustment

Time of of gate1

Time of of gate2

After automatic learning, the trip is not

ideal can be adjusted manually, the

shorter the time deceleration distance

is more far.

Photo Sensor

N/C; photo sensor normally is

on.(Default)

N/O; photo sensor normally off.

N/O; photo sensor normally

on.

Electric Lock

Electric lock normally is on. (Default)

Electric lock normally is off.

Electric lock normally on.

Alarm Lamp

Alarm lamp normally is on. 24V power

supply. (Default)

Alarm lamp normally flashes. 24V

power supply.

Alarm lamp normally is on.

24V power supply.

Low Consumption Mode

Low consumption mode on.The

control board will automatically enter
low-consumption mode after one minute when
there is no operation at the initial screen.
(Default)

Low consumption mode off.

Low consumption mode on.

Summary of Contents for SW300DC

Page 1: ...SW300DC Swing Gate Opener User Manual ...

Page 2: ...y Installation 7 8 3 Dimension of Control Box 10 9 Wiring and Debugging 11 9 1 Wiring Instructions 11 9 2 Control Board Drawing and Instructions 12 9 3 Digital Screen Setting 13 9 4 Travel Setting 13 9 5 Trimmer Setting 14 9 6 Learning Remote Control Delete Remote Control 14 9 6 1 Learning Remote Control 14 9 6 2 Delete Remote Control 14 9 6 3 Special Remote Control Key button 15 9 7 Control Board...

Page 3: ...rements The disposal of packaging material must be complying with the local regulation Please do not change any parts except for those defined under this manual Any undefined changes may cause the malfunction Any damages to the product arising therefrom shall be beyond the liability of the company Please do not leak water or any liquid into the controller or any other open devices Please disconnec...

Page 4: ...tity 1 Main machine 2 2 Control box 1 3 Manual release key 2 4 Remote control 2 5 Wall bracket 4 6 Front mounting bracket 2 7 Connecting bracket 2 8 Screw M8X25 4 9 Mounting screw short 2 10 Screw M8 45 2 11 Self locking Nut M8 8 12 Limit stopper 1 ...

Page 5: ...re the these installation accessories according to actual site situation 3 Technical Parameters Model SW300DC Power supply 220V 50Hz 110V 60Hz Motor power 50W Gate moving speed 18 22s 90 Max single leaf weight 300kg Max single leaf length 2 5M Max force 2600N Max piston stroke 32cm Remote control distance 30m Remote control mode Single Four button mode Storage battery optional DC24V 4 5Ah or 9Ah N...

Page 6: ...e mode adopts planetary transmission to combine with the screw rod transmission This gate opener must be installed inside the enclosure or yard for protection 5 Tools Needed for Standard Installation No 6 Allen Wrench Spirit Level Slotted Screwdriver Tape Phillips Screwdriver Adjustable Wrench X 2 Hatching Pen Note the cables must be suitable for outdoor use ...

Page 7: ...f infrared sensor 2 0 5mm 10m 4 Cable of alarm lamp 2 0 5mm 10m 5 Cable of electric lock 2 0 5mm 10m 6 Extension cable of storage battery 2 1 5mm 10m 7 Cable of solar power 2 1 5mm 10m Due to different installation environments installer need to prepare power cables for control box and for gate openers Note cable outlet should be downward to prevent rainwater from entering wire along the cable ...

Page 8: ... Gate Opens Inwards Figure 2 7 2 Gate Opens Outwards Figure 3 A B 100mm 120 mm 140 mm 160 mm 180 mm 200 mm 100mm 102 101 99 98 97 97 120mm 111 108 106 104 103 99 140mm 118 115 112 102 93 96 160mm 117 107 98 91 180mm 103 96 90 200mm 94 ...

Page 9: ...d 300 800mm above the ground and make sure there are reliable fixed points for mounting brackets 8 1 1 Cable Bury In order to ensure the normal operation of the gate opener and protect the cable from damage please use two PVC pipes to bury the motor and power cables and the control cables separately One PVC pipe for motor and power cables the other one for control cables 8 1 2 Mounting Brackets Fi...

Page 10: ...the installation please unlock the two main machines Unlock method Open the manual release cover insert the manual release key rotate the key until it s released as shown in Figure 6 then turn the telescopic arm you ll find it s stretched by hand easily Figure 6 D Connect the main machine with connecting brackets by screw and nut as shown in Figure 7 ...

Page 11: ...n in figure 8 below connect wall bracket with wall according to marked position Then connect main machine with wall bracket by screw and nut Please use spirit level to make sure the installation levelness Figure 8 Figure 9 ...

Page 12: ...ion as shown in figure 2 Before installing the main machine please make sure the main machine and components are in good mechanical performance and the gate can be manually operated flexibly One control unit can optionally drive one main machine or two main machines Earth leakage circuit breaker must be installed on where the gate movement can be seen and the minimum mounting height for the contro...

Page 13: ...USE 10A 10A 24V 24V battery battery input input 24V 24V battery battery input input Solar Solar power power input input Solar Solar power power input input Motor2 Motor2 Electric Electric Lock Lock Alarm Alarm Lamp Lamp 24V 24V 12V 12V Motor1 Motor1 Limit Limit signal signal Common Common Motor1 Motor1 Limit Limit power power supply supply Motor2 Motor2 Limit Limit power power supply supply Motor2...

Page 14: ... 4 FORCE Resistance Force 5 SLOW DOWN Slow Stop Distance 6 SPEED Moving Speed 7 MOTOR1 Motor1 Output 8 MOTOR2 Motor2 Output 9 ELOCK Electric Lock Output 10 BLK Alarm Lamp Output Note pay attention to the negative and positive 11 24V 24V Output Positive 12 12V 12V Output Positive No output under dormant state 13 EM1 Motor1 Hall Sensor Power Output 14 LM1 Motor1 Hall Sensor Limit Signal Input 15 EM2...

Page 15: ...il the digital screen shows SU After this step the gate will firstly run towards the closing direction and stop and then the gate will automatically open When the two swing gates are fully open the gates will automatically close for the second time and the travel setting will be completed when the gates are closed If the distance of starting slow speed of gate is not appropriate adjust the SLOW DO...

Page 16: ... travel setting Figure 13 9 6 Learning Remote Control Delete Remote Control 9 6 1 Learning Remote Control Press and hold button the alarm light will keep flashing and digital screen displays remote control mode PO two swing gates single channel mode Pd single gate four channel mode Press the button of the remote control to be learned the digital screen will show the number of current learned remot...

Page 17: ... select other functions of this menu by and buttons Press SET to confirm or to enter into sub menu To exit menu press PROG If no command for one minute the menu will automatically exit Base Menu Automatic closing mode Standard mode Open Close Stop Dual gates mode To switch single gate mode dual gates mode Single gate mode Community mode Open gate time interval 3 seconds default 15 seconds default ...

Page 18: ...16 Remote control mode Dual gates single channel mode Four channel mode Single gate single channel mode Delete remote control ...

Page 19: ...on When the gate opens any gate command will not be responded until it closes automatically If user sends gate command during the closing process then the gate will reopen If a gate command is sent during the automatic closing waiting time this waiting time will be recalculated If the gate is not closed completely for more than three consecutive times the automatic closing function will be cancele...

Page 20: ...l shorter than 2 seconds then the electric lock cannot be used 3 seconds Automatic Closing Time Automatic closing time can be set as 15 default 30 60 90 seconds 15 seconds Remote Control Mode Dual gates single channel mode Four channel mode Single gate single channel mode Delete all paired remote controls ...

Page 21: ...exit If no command for one minute the menu will automatically exit Advanced Menu Photo sensor Photo sensor normally on Initial screen Photo sensor normally off Electric lock normally on Alarm lamp Electric lock Alarm lamp normally flash Low consumption mode off Low consumption mode Alarm lamp normally on Low consumption mode on Time of of gate 1 Time of of gate 2 Travel time adjustment Electric lo...

Page 22: ...20 Gate opener secection Stop block Hall sensor Default setting cancellation Factory default setting Limit switch mode Factory default setting SW400DC SW300DC SW200DC ...

Page 23: ...sor normally is on Default N O photo sensor normally off N O photo sensor normally on Electric Lock Electric lock normally is on Default Electric lock normally is off Electric lock normally on Alarm Lamp Alarm lamp normally is on 24V power supply Default Alarm lamp normally flashes 24V power supply Alarm lamp normally is on 24V power supply Low Consumption Mode Low consumption mode on The control ...

Page 24: ...it Switch Mode Stop block Default Hall sensor Stop block Gate Opener Secection SW400DC SW300DC Default SW200DC SW300DC Factory Default Setting Cancel factory default setting Factory default setting completes ...

Page 25: ...re that the 5 and 6 5 and 7 short circuit if connect infrared sensor please make sure the wiring is correct and the photocell is N C 2 Make sure that the photocell mounting position can be mutually aligned 3 Remove the obstacle 4 Reduce the sensitivity of obstacle Remote control doesn t work 1 Battery level of the remote control is low 2 Remote control learning is not completed 1 Change the remote...

Page 26: ...ar after the date of invoice 3 Without unauthorized dismantling any product broken or damage due to quality problem we ll offer the repair service for free or replace for free 4 The malfunction and damages caused by incorrect use or man fault is not covered by this warranty Maintenance Record Check Date Check Content Maintained by ...