Cuff loose Indicator
At the beginning of the measurement, when the cuff is properly worn, the " " icon will be
displayed, and when thecuff is loose, " " The icon will be displayed. When this happens,
please turn off the machine, adjust the cuff and measure again. If the " " icon is still
displayed, please check the cuff plugconnect with device correctly and measure again.
If it still cannot be resolved, please contact the seller or manufacturer.
OK
2. Testing
After cuff inflation, air will slowly rise as indicated by the corresponding cuff pressure
value. A flashing " " will appear simultaneously on screen signaling heart beat
detection.
Note: Keep relaxed during testing. Avoid speaking or moving body parts.
3. Result Display
The screen will display measurements for systolic and diastolic blood pressure with
voice broadcast. An indicator representing the current measurement will appear next to
the corresponding WHO Classification.
Irregular Heartbeat Indicator
If the monitor detects an irregular heart rhythm two or more times during the measuring
process, the Irregular Heartbeat Symbol " "appears on screen along with
measurement results. Irregular heartbeat rhythm is defined as rhythm that is either 25%
slower or faster than the average rhythm detected while measuring systolic blood pressure
and diastolic blood pressure. Consult your physician if the Irregular Heartbeat Symbol
" " frequently appears with your test results.
Power Off
turn off the power itself about 3 minutes no operation in any mode.
The " START/STOP " button can be pressed to turn off the unit in any mode. The unit can
Note: Refer to Page 23~24 for detail WHO Blood Pressure
Classification Information.
Safety Precaution: If pressure in arm cuff becomes too extreme while testing,
press the " START/STOP " button to turn power off. The cuff pressure will rapidly
dissipate once the unit is off.
Testing
1. Power On
Press and hold "START/STOP" button to turn the unit on. The LCD screen will appear
for one second as unit performs a quick diagnosis. A voice tone will indicate when unit is
ready for testing.
Note: Unit will not function if residual air from previous testing is present in cuff.
The LCD will flash " " until pressure is stabilized.
IHB
IHB
IHB
1
2
3
AM
AM
Last 3 Tests Average
With power off
,
press the "MEM" button to activate screen display. After the unit performs
a self-diagnosis ,the screen will display the average test results from the last 3 readings
of the last group used. The "AVG" symbol will appear along with the corresponding
WHO Blood Pressure Indicator. The Memory Check mode can be accessed by
pressing "MEM" button. To check the average results from other groups, select the
desired group first prior to activating "SET" button in the off position.(See "Select
Memory Group" on Page 12)
AM
You may check past test results by using the "MEM" button. The
most recent test result and oldest test result in memory can be viewed by pressing
and holding the "MEM" button. Upon activating test results. you can press the "MEM"
button to scroll through all test results stored in memory.
Memory Check
AM
Memory Deletion
Memory for a selected group may be deleted while in Memory Check mode. Press and hold
the " SET " button for approximately 3 seconds to delete all memory records from the
selected groupwith voice broadcast "Memory Clear" and then transfer into
testing mode. Press the "START/STOP " button to turn the unit off.
Note: Memory cannot be recovered once it has been deleted.
AM
AM
If there is arm movement during the measurement, " " may be shown. Indicates that this
may lead to abnormal measurement results, and the LCD screen will display " " after the
measurement is finished.
Arm Shake Indicator