2. Testing
After cuff inflation, air will slowly rise as indicated by the corresponding cuff pressure
value. A flashing " " will appear simultaneously on screen signaling heart beat
detection.
Note: Keep relaxed during testing. Avoid speaking or moving body parts.
17
16
18
Unit Operation
Unit Operation
Unit Operation
3. Result Display
The screen will display measurements for systolic and diastolic blood pressure with voice
broadcast. A indicator representing the current measurement will appear next to the
corresponding WHO Classification.
Irregular Heartbeat Indicator
If the monitor detects an irregular heart rhythm two or more times during the measuring
process, the Irregular Heartbeat Symbol " "appears on screen along with
measurement results. Irregular heartbeat rhythm is defined as rhythm that is either 25%
slower or faster than the average rhythm detected while measuring systolic blood pressure
and diastolic blood pressure. Consult your physician if the Irregular Heartbeat Symbol
" " frequently appears with your test results.
Power Off
turn off the power itself about 3 minutes no operation in any mode.
The " START/STOP " button can be pressed to turn off the unit in any mode. The unit can
Note: Refer to Page 23~24 for detail WHO Blood Pressure
Classification Information.
Safety Precaution: If pressure in arm cuff becomes too extreme while testing,
press the " START/STOP " button to turn power off. The cuff pressure will rapidly
dissipate once the unit is off.
Unit Operation
15
Last 3 Tests Average
You may check past test results by using the "MEM" button. The
most recent test result and oldest test result in memory can be viewed by pressing
and holding the "MEM" button. Upon activating test results. you can press the "MEM"
button to scroll through all test results stored in memory. To check the average results from other
groups, please press corresponding "GROUP1" button or "GROUP2" button.
With power off, press the "MEM" button to activate screen display. After the unit performs
a self-diagnosis ,the screen will display the average test results from the last 3 readings
of the last group used. The "AVG" symbol will appear along with the corresponding
WHO Blood Pressure Indicator. The Memory Check mode can be accessed by
pressing "MEM" button. To check the average results from other groups, please press
corresponding "GROUP1" button or "GROUP2" button.
Memory Check
IHB
IHB
Note: Do not insert air plug into opening located on right side of monitor unit.
This opening is designed for an optional power supply only.
1-
2c
m
''
(0
.4
-0
.8
)
Testing
1. Power On
Press and hold "START/STOP" button to turn the unit on. The LCD screen will appear for one
second as unit performs a quick diagnosis. A voice tone will indicate when unit is ready for
testing.
Note: Unit will not function if residual air from previous testing is present in cuff.
The LCD will flash " " until pressure is stabilized.
If there is arm movement during the measurement, " " may be shown. Indicates that
it may lead to abnormal accurate measurement results. At this time,the LCD will display
" Err".
Arm Shake Indicator
When starting the measurement, " "will be displayed when the cuff is properly wound.
When the cuff is too loose, " "will be displayed. At this time, please wear the cuff correctly
and start measuring again.
Cuff loose Indicator
OK