57
When the green cursor is at “ ”or” ”, press
“ ” to set the time period as on or off. Press
“ ”, entering into time setting. Press “ ”
to move the cursor. Press “ ”and “ ” to set
the time. Press “ ”and “ ” to exit the time
editing. And cursor will be move back to the very left
side. After the time setting is done, press “ ” to
return and store the setting.
Heating time
When the control system is set as timing heating mode, heater can operate automatically
in two sets of the time periods. And the two time periods are independent from each other.
Two time period can be set overlapped, like time period 06:15 ---13:15, , time period
10:15---16:15. Then heater will work between 06:15---16:15. if the starting time is larger
than the ending time, then heater will continuously work till the end time of next day, for
example if the time period is between 20:00---10:00, then the heater will work from the
20:00 of first day till the 10:00 of the next day. Note: when the time period is set as on, the
heater will work, if time period is set as off, heater will turn off.
Note:
These set times are all based on system time. So user need to ensure the accuracy
of the system time when setting the time period.
PB553/PB555 setting interface
Control panel operation instruction