Joyonway PB553 Operation Instruction Manual Download Page 1

PB553/PB555control panel image

Control panel operation instruction 

49

PB553 panel image

PB555 panel image

set: 

95

 

32

 

Jets 1

Jets 2

Jets 3

11:55

09-Mar

MON

3

2

1

Blower

Heat

1

MENU

4

3

2

1

Mode:

off

Cycle pump

 on

 

set: 

95

 

32

 

Jets 1

Jets 2

Jets 3

11:55

09-Mar

MON

3

2

1

Blower

Heat

1

MENU

4

3

2

1

Mode:

off

Cycle pump

 on

 

Summary of Contents for PB553

Page 1: ...struction 49 PB553 panel image PB555 panel image set 95 32 Jets 1 Jets 2 Jets 3 11 55 09 Mar MON 3 2 1 Blower Heat 1 MENU 4 3 2 1 Mode off Cycle pump on set 95 32 Jets 1 Jets 2 Jets 3 11 55 09 Mar MON...

Page 2: ...ole system User can easily learn the control system condition with the icons and words Main interface image State display area Below are control panel interfaces of PB553 and PB555 Both control panel...

Page 3: ...speed pump of pump 1 is started 1 will be displayed in the up left corner with orange background Other pumps are with the similar displaying method with pump1 6 Blower state display when the blower i...

Page 4: ...control system Press left or right key to switch for different control system The current interface displays the control system that the thicker bar represent With basic control system there will be...

Page 5: ...1 Screen Invert light navigation key up confirm set 95 32 Jets 1 Jets 2 Jets 3 11 55 09 Mar MON 3 2 1 Blower Heat 1 MENU 4 3 2 1 Mode off Cycle pump on PB553 keys description Control panel operation...

Page 6: ...an start or stop the correspondent function in any interface without returning to home interface Pump 1 shortcut key or will be used to control the on off of pump 1 if pump 1 is single speed pump if p...

Page 7: ...states of auto color change red green yellow blue purple cyan white and turning off User can switch among these states Mode selecting shortcut key It is only applicable for PB553 It has four different...

Page 8: ...l disappear Move the cursor to the last item set in the menu of the home interface press and enter into setting interface There are totally 11 items in the setting interface including auxiliary system...

Page 9: ...er Two time period can be set overlapped like time period 06 15 13 15 time period 10 15 16 15 Then heater will work between 06 15 16 15 if the starting time is larger than the ending time then heater...

Page 10: ...an it is necessary to filter the water regularly When the control system is set as timing water cycle mode its starting and stopping method is the same as timing heating on off and their time period s...

Page 11: ...ect the mode stored In the main interface by pressing and to move the cursor to Then press to select the stored the modes PB 553 control panel can use mode selecting short cut key Note please pre set...

Page 12: ...tion is on The heater will automatically heat Ozone Ozone function has manual mode and auto mode In the Set of the menu by pressing and to move the cursor to Ozone Then press to set the ozone as auto...

Page 13: ...ting no actions on the panel key within the set time When the lock is started press continuously for 3S Auto Lock disappear from the screen and lock stops To ensure that user can use the control syste...

Page 14: ...the menu If the control system is off power the correct time setting can be kept for a few days Wifi When the control system is connected with Wifi module in the Set of the menu there will be Wifi ch...

Page 15: ...jet 1 low speed pump is set as cycle pump 63 Function Function setting is used to set control system loads and Panel ID When the control system is allowed to be set please refer to the description in...

Page 16: ...e blower function is set No means it is invalid To panel ID it can be set as 1 2 3 or 4 these numbers are used to differ control panels and the control panel ID must be unique To other loads if the fi...

Reviews: