42
Note
1. The TCR values listed in the table are the actual TCR
value multiplied by 10
5
.
2. The TCR value range is 1 – 1000.
INNOCIGS EVIC VTWO – OPERATING & CHANGING THE MODES
Adjusting the TCR mode
While the eVic VTwo is turned off, press and hold the fire button and turn the control knob to the right at
the same time for about 5 seconds to enter in the TCR-menu:
1. Turn the control knob to the right or to the left to switch between TCR M1, M2 and M3.
2. Confirm the desired mode by pressing the fire button.
3. Turn the control knob to the right or to the left to increase or decrease the settings.
4. Confirm your setting with the fire button or wait 10 seconds.
Material
TCR Value Range
Nickel
600-700
NiFe
300-400
Titanium
300-400
SS (303, 304, 316, 317)
80-200
TCR value range for various materials