background image

QuickCharge detection

The meter automatically recognizes devices with QuickCharge support. 

The following QuickCharge modes are currently supported:

QC2.0. QC3.0, Apple 2.4 A / 2.1 A / 1 A / 0.5 A, Android DCP, Samsung

Recording of charging process

Voltage of 

D+ (DP)

Voltage of  

D- (DM)

Mode indicator

Accumulated  

electrical loading

Accumulated 

energy

Total 

accumulation 

time

Trigger current

for recording

Recording indicator

Red

: Recording paused

Green

: Recording in process

After power is turned on, if the flowing current is greater than the trigger 

value, the system automatically starts recording the 

accumulated electrical charge, energy and elapsed time. The „REC“ indica-

tor then changes from red to green.

To set the current trigger value, press  

 

 

and hold it to 

highlight the value. Press    

 

to adjust the value accordingly. 

The value can be set anywhere between 0.01 A and 0.3 A.

Summary of Contents for JT-UM25C

Page 1: ...connections are of best quality and deliver even currents and voltages With the JT UM25C you always have all values in view The meter supports additional functions such as Quickcharge 2 0 and 3 0 as...

Page 2: ...4 24 V 0 5 A 2 Hz 0 001 V 0 0001 A 10 100 C 1 44 QC2 0 QC3 0 Apple 2 4 A 2 1 A 1 A 0 5 A Android DCP Samsung USB A Port female BT switch 4x multifunctional buttons microUSB Port USB C Output only VBU...

Page 3: ...ement result main page QuickCharge detection Recording of charging process Cable impedance Measurement graph System settings Use and to switch between the separate menu pages Hold to switch to the nex...

Page 4: ...age Current Accumulated electrical loading Accumulated energy Temperature Data group Equivalent resistance Power consumption The values of the data group 1 9 will be saved by a voltage interruption of...

Page 5: ...nergy Total accumulation time Trigger current for recording Recording indicator Red Recording paused Green Recording in process After power is turned on if the flowing current is greater than the trig...

Page 6: ...the resistance measurement test of the data connection cable is completed and the value is displayed UM25C directly at the power supply system Voltage and current values are displayed UM25C via data...

Page 7: ...enter the setting mode press again to navigate through the options Then press to change a setting and press again to cycle through the setting options At each setting state press and hold to exit the...

Page 8: ...to connect the instrument to your computer To do this select in the BT connection overview BT settings In the window that now opens select the COM ports tab The necessary interface in this case is UM...

Page 9: ...open the UM25C PC software V1 3 which you have already installed on your computer First set the appropriate COM port to which the measuring device is connected to your computer and start the connecti...

Page 10: ...interface Temperature overview Screen brightness Time for automatical image shut down Voltage current diagram With a right click within the voltage current diagram further options are available Here...

Page 11: ...either 0000 or 1234 as the PIN during connection After the installation and connection is complete you can start the application 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Data export Language settings BT conn...

Page 12: ...int Before handing over waste batteries and accumulators that are not enclosed by waste equipment must be separated from it Return options As an end user you can return your old device which essential...