Joy-it JT-RD6012-C Manual Download Page 7

www.joy

-

it.net

 

Pascalstr. 8 47506 Neukirchen

-

Vluyn

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7.

 

Main Page Style setting

 

You can press 'SHIFT' + '0' to enter the system setting menu and then press the right 

button to enter the main page style setting menu as shown above. Press ENTER and 

then use the direction button to set classic style or curve style. The pattern in red is 

the style be chosen. The classic style is the system default style and the large font 

shows the voltage, current and power. The curve style is, as shown above, the colour 

of the three curves corresponds to the output voltage, current and power. D is the 

scale of the value, Press 'ENTER' to start or pause the curve and the rotary encoder to 

scale the values of the curve.

 

 

8.

 

Storage Data Setting 

 

You can press 'SHIFT' + '0' to enter the system setting menu, then press the right but-

ton twice to enter the data storage setting menu as shown below, press ENTER to 

enter the setting menu, the icon in red is the chosen data group, press the direction 

button to select data group number. Press 'I

-

SET' button to set the storage output 

current value, then rotate the encoder to adjust the output value, press the direction 

button to move the cursor. You can also set the value with keypad, press ENTER to 

confirm. If you set the wrong value, you can press the encoder potentiometer to can-

cel. Press 'V

-

SET' button to set the storage output voltage value, the operation meth-

od is similar to storage output current setting. Press 'SHIFT'+ 

“'

I

-

SET' button or 

'SHIFT'+ 'V

-

SET' button to set the storage overcurrent protection/ storage overvolt-

age protection value. The operation method is similar to storage output current val-

ue setting. Press the Encoder Potentiometer to return and the data will be automati-

cally saved.

 

 

9.

 

System Information

 

You can press 'SHIFT' + '0' to enter the system setting menu, then press the right but-

ton three times to enter the system information menu as shown above. You can view 

the SN number, firmware version and system temperature here.

 

 

 

Summary of Contents for JT-RD6012-C

Page 1: ...to contact us The RD6012 C is a laboratory power supply that can be used in various operating modes e g constant current or constant voltage operation etc A keypad and a push and turn encoder make th...

Page 2: ...gits Output voltage accuracy 0 3 3 digits Output current accuracy 0 5 5 digits Battery voltage measurement accuracy 0 5 3 digits Input voltage measurement resolution 0 01 V Output voltage measurement...

Page 3: ...al Power supply output battery charging nega tive terminal Micro USB Interface Second function button Power button Quick storage button Current Overcurrent protection value setting Voltage Overvoltage...

Page 4: ...www joy it net Pascalstr 8 47506 Neukirchen Vluyn 4 3 Case Back Panel Main on off switch Temperature sensor socket Mains socket 230 V AC 50 Hz Ventilation openings do not cover...

Page 5: ...oaches the final charge voltage the device will reduce the charge current until it falls below 10 mA and it will stop charging The device indicates charging with a green symbol of the battery Note tha...

Page 6: ...y when start If you turn it off the out put will keep OFF status when started Turn on the Beeper you will hear button tune when pressing the button and there will be on the top If you turn it off ther...

Page 7: ...enter the setting menu the icon in red is the chosen data group press the direction button to select data group number Press I SET button to set the storage output current value then rotate the encod...

Page 8: ...urchase a new device Small appliances with no external dimensions greater than 25 cm can be disposed of in normal household quantities independently of the pur chase of a new appliance Possibility of...