Joy-it JT-RD6012-C Manual Download Page 2

www.joy

-

it.net

 

Pascalstr. 8 47506 Neukirchen

-

Vluyn

 

 

 

2. TECHNICAL SPECIFICATIONS

 

3. SCREEN OVERVIEW

 

Current data group

 

Constant voltage/Constant current status

 

Protection status indication

 

Button lock status

 

Communication Interface

 

Battery charging indication

 

Battery

-

related information

 

Overcurrent protection value

 

Overvoltage protection value

 

Output voltage preset value

 

Output current preset value

 

Button tune

 

Time

 

Input voltage

 

Current output voltage

 

Current output power

 

Current output current

 

Display

 

2.4 " colour LCD

 

Input voltage range

 

230 V AC

 

Output voltage range

 

-

 60 V DC

 

Output current range

 

-

 12 A

 

Output power range

 

-

 720 W

 

Input voltage accuracy

 

± 1 % + 5 digits

 

Output voltage accuracy

 

± 0,3 % + 3 digits

 

Output current accuracy 

 

± 0,5% + 5 digits

 

Battery voltage measurement accuracy

 

± 0,5% + 3 digits

 

Input voltage measurement resolution

 

0,01 V

 

Output voltage measurement resolution

 

0,01 V

 

Current setting measurement resolution

 

0,01 A

 

Battery voltage measurement resolution

 

0,01 V

 

Constant voltage mode response time

 

2 ms at 0,1 

-

 5 A load

 

Constant voltage mode load regulation

 

± 0,1 % + 2 digits

 

Constant current mode load regulation

 

± 0,1 % + 3 digits

 

Capacity measurement range

 

-

 9999,99 Ah

 

Energy measurement range

 

-

 9999,99 Wh

 

Capacity and Energy statistical error 

 

± 2 %

 

Output ripple 

 

typ. 100mV VPP

 

Sensor temperature detection range

 

-

10 

-

 100°C / 0

-

 200 ° F

 

Sensor temperature detection accuracy

 

± 3° C / ± 6 °F

 

Working mode

 

step down (buck) mode

 

Voltage drop

 

min. 1V and min. 10  %

 

Screen brightness setting

 

Level 0 

-

 5, 6 levels total

 

Working temperature range

 

 

-

 10° 

-

 40 ° C

 

Summary of Contents for JT-RD6012-C

Page 1: ...to contact us The RD6012 C is a laboratory power supply that can be used in various operating modes e g constant current or constant voltage operation etc A keypad and a push and turn encoder make th...

Page 2: ...gits Output voltage accuracy 0 3 3 digits Output current accuracy 0 5 5 digits Battery voltage measurement accuracy 0 5 3 digits Input voltage measurement resolution 0 01 V Output voltage measurement...

Page 3: ...al Power supply output battery charging nega tive terminal Micro USB Interface Second function button Power button Quick storage button Current Overcurrent protection value setting Voltage Overvoltage...

Page 4: ...www joy it net Pascalstr 8 47506 Neukirchen Vluyn 4 3 Case Back Panel Main on off switch Temperature sensor socket Mains socket 230 V AC 50 Hz Ventilation openings do not cover...

Page 5: ...oaches the final charge voltage the device will reduce the charge current until it falls below 10 mA and it will stop charging The device indicates charging with a green symbol of the battery Note tha...

Page 6: ...y when start If you turn it off the out put will keep OFF status when started Turn on the Beeper you will hear button tune when pressing the button and there will be on the top If you turn it off ther...

Page 7: ...enter the setting menu the icon in red is the chosen data group press the direction button to select data group number Press I SET button to set the storage output current value then rotate the encod...

Page 8: ...urchase a new device Small appliances with no external dimensions greater than 25 cm can be disposed of in normal household quantities independently of the pur chase of a new appliance Possibility of...

Reviews: