11

ENGLISH

3.0 Safety precautions

3.1 Fire preventive measures

Any use of the fireplace may represent some danger.

  

Therefore, 

respect the following instructions:

 

•  Ensure that furniture and other flammable materials do not 

get too close to the fireplace. 

•  Let the fire die. Never put it out with water as this may 

damage the product.

•  The fireplace gets warm when used and may cause burns if 

touched.

•  Only remove ashes when the fireplace is cold.
•  Ash must be properly disposed of outdoors, or emptied where 

it does not entail a fire hazard.

3.2 Air supply

Warning!

 Please ensure that there is adequate air supply from 

the outdoors to the room in which the fireplace is to be installed.

Ensure that air vents in the room where the fireplace is located 
are not blocked.

An inadequate air supply could cause smoke gas to escape into 
the room. This is very dangerous! Symptoms of this include 
smoky smell, drowsiness, nausea and feeling ill.

Avoid using mechanical fan vents in a room with a fireplace.  
This may cause negative pressure and draw poisonous gasses 
into the room.

4.0 Installation

4.1 Floor

Foundations

Ensure that the floor is strong enough for the fireplace. See 

«2.0 

Technical data»

 for weights. It is recommended that flooring 

which is not fastened to the foundations – so-called floating 
flooring – is removed during installation. 

Wooden floor protection 

Requirements for the floor plate:

The floor plate must be in accordance with national laws and 
regulations. (See 

Building regulations

)

We recommend that you contact the local Jøtul dealer prior to 
the installation.

Any flooring made of combustible material, such as linoleum, 
carpets, etc. must be removed from under the floor plate.

Requirement for protecting combustible 
flooring in front of fireplace

The front plate must be in accordance with national laws and 
regulations. 

Contact your local building authorities regarding 

restrictions and installation requirements.

4.2 Wall

Distance to walls made of combustible 
material covered by insulation - see fig. 1

Requirements for insulation

50 mm rock wool 120 kg/m

3

 foliated on one side with 

aluminium.

Distance from the product to the insulation on the back panel:  
0 mm.

Requirements for the stove surround

The stove surround must be made in an 

incombustible material

 

and be carried out in accordance with the requirements indicated 
under section:  

«3.0 Safety precautions».

Note that the entire back panel within the surround must be 
covered by insulation.

If the stove cowling is bricked up to the ceiling and the ceiling is 
made of combustible material, on top of the warming chamber 
and the cowling vents an extra ceiling panel must be installed 
to avoid heating the ceiling.
 

For example use: 

Rock wool 100 mm thick on top of a steel plate min. 0,9 mm.

Ensure airing out the top of the stove cowling – for example an 
opening towards the ceiling, or approx. 

cm

opening 

(fig. 2)

.

Note: Remember that it should be possible to sweep and to 
inspect the installation.

4.3 Air circulation (fig. 2) 

Air should be allowed to flow between the insert and the 
brickwork, and it is very important that there is a free air supply 
to the draft catcher on top of the insert.  See 

fig. 2.

The required air vent sizes for Jøtul I 

80 

RH  (for air circulation) are:

Base:    Minimum of 500 cm

2

 

free ventilation.

Top:      Minimum of 750 cm

2

 free ventilation.

This is a safety measure to prevent a build up of heat in the 
surround, and also to ensure sufficient heat emission into the 
room.

If the house is badly ventilated, the room must be equipped with 
extra fresh air circulation, for example by means of separate air 
channels or a separate channel directly to the top of the fireplace. 
 
The fresh air channel should be as straight as possible. It should 
be possible to close the channel with a damper in order to keep 
out cold air when the fireplace is not being used. 

4.4 Ceiling

Jøtul I 

80

 RH have been approved for:

min. 800 mm

 distance from warm air opening in the hood’s 

top  to a ceiling of c0mbustible material.

Summary of Contents for I 80 RH

Page 1: ...zione ed uso 34 DE Montage und Bedienungsanleitung 42 NL Installatie en montagehandleiding 50 RU 58 Figures Pictures 67 Monterings ogbruksanvisningenm oppbevaresunderheleproduktetslevetid Theseinstruc...

Page 2: ...to using the product the installation must be inspected by a qualified person A product data label in heat resistant material is located on the heat shield at the back of the product This contains inf...

Page 3: ...rictions and installation requirements 4 2 Wall Distance to walls made of combustible material covered by insulation see fig 1 Requirements for insulation 50 mm rock wool 120 kg m3 foliated on one sid...

Page 4: ...installation easier remove the entire front including the doors See section Service 3 Place the wooden pallet and the cardboard packaging on the floor and lay the fireplace carefully down on its back...

Page 5: ...portant that the system is used correctly Anotherimportant factorforproperfuelconsumptionis that the logs are the correct size The size of the logs should be Kindling Length Approx 35 cm Diameter 2 5...

Page 6: ...remove the ash through the door Always leave some ash as a protective layer on the bottom of the fireplace Ash must be placed in a metal container with a sealed lid Also see the description below abo...

Page 7: ...nnecting pipe if it has already been connected Unscrew the screw A which is on the door frame at the top in the middle The nut is situated at the back Hook the regulating bar B on the damper C from th...

Page 8: ...for insert s heat shield 8 5 Ash compartment cat no 51012053 fig 13 Remove the internal screw in the middle of the bottom of the combustion chamber so that the fire plate and the cross bar can be remo...

Page 9: ...guishes after a while Make sure that the firewood is sufficiently dry Findout whether thereisnegativepressurein thehouse close mechanical fans and open a window close to the stove Check that the air v...

Page 10: ...siden bedriftens historie startet i 1853 Qualit t J tul AS hat ein Qualit tssicherungssystem das sich bei Entwicklung Produktion undVerkauf von fen und Kaminen nach NS EN ISO 9001 richtet Diese Qualit...

Reviews: