background image

32

Fitting the bottom frame (fig. 5) (Jøtul I 

80

 Mini/

Maxi - Harmony and Panorama)

1.  Remove the knob on the bar for the lower air vent 

(fig. 5A)

.

2.  Place the bottom frame 

(B)

 so that the bar passes through 

the hole in the frame.

3.  Fasten the bottom frame with 2 screws 

(C)

 M6x12.

4. Refit 

the 

knob.

Ash lip 

Place the ash lip next to the bottom frame.

Ash moulding/log stopper

Put the ash moulding into place in the columns situated on the 
bottom of the sides between the front and side burn plates.

Assembly of the flue connecting pipe (fig. 6)

1.  The flue connecting pipe 

(A)

, which is packed in the box, is 

placed on the top of the fireplace. Place the flue connecting 
pipe in such a manner that the screw attached to it, is facing 
outwards.

1.  Place one clamp iron 

(B)

 on each side. These are held in place 

with a screw 

(C)

 M8x30mm and with nuts.

 

4.7 Set up/installation

The product is heavy! Make sure you have assistance when 
erecting and installing the fireplace.

Assembly of the chimney (fig. 7)

1.  Carry out a trial mount of the insert prior to making a hole 

in the chimney. See 

fig. 1 

for distances.

2.  The insert may be assembled with either an Ø150mm or an 

Ø175mm flue pipe. This should be 2,3 mm thick - enamelled. 

NB! Standard flues of 1mm thickness should not be used. The 
supplier can deliver 100

o

 special bends which are adapted to 

the insert.

3.  The flue pipe bend should be assembled directly onto the 

insert and should be able to rotate 360

o

. Pipe Ø150 mm is 

assembled on the inside of the smoke outlet and the Ø175 
mm is assembled on the outside.

4.  Adapt the flue pipe’s length with an overlap of 40 mm, both 

in the flue pipe bend and  in the chimney collar.

5.  Guide the adapted flue pipe into the chimney collar. Attach it 

and pull the pipe back into the flue bend. (Use the enclosed 
rope seal).

6.  Place the insert into its final position. With the aid of a furnace 

cement (or possibly some rope seal), the flue pipe bend is 
placed in the insert’s smoke outlet.

7.  The flue pipe must be attached to the smoke outlet at the 

front edge with an M6 self cutting screw 

(7A)

. Use an Ø5,5 mm 

drill and make a hole in the flue pipe for the screw.

NB! It is important that the joints/flue pipes are completely 
sealed. Air leakage etc. may lead to malfunction.

4.8 Control of functions (fig. 8)

When the product is set up, always check the control functions. 
These shall move easily and function satisfactorily.

Ignition ventilator (A)

Pushed in       = 

closed.

Pulled out      = 

open.

Top draught (B)

Left position       =  closed.  
Right position    =  fully open.

Door lock  - Mini/Maxi - Classic and Harmony (C)

 

Place the handle in the groove on the right hand door and turn it 
upwards. Open and close the left door in the same way.

Door lock  - Panorama

Place the handle in the groove on the  door and turn it 
upwards.

Damper (D)

Damper is accessory - (if equipped)
Pushed in      =  open.
Pulled out     =  closed.

ENGLISH

Summary of Contents for I 80 Maxi Classic

Page 1: ...nstalaci n 47 IT Manuale di installazione ed uso 56 DE Montage und Bedienungsanleitung 65 NL Installatie en montagehandleiding 74 Figures Pictures 83 Monterings og bruksanvisningen m oppbevares under...

Page 2: ...output 6 0 kW 9 0 kW Smoke gas mass flow 5 4 g s 8 1 g s Rec chimney draught 12 Pa 12 Pa Effiency 83 4 9 kW 80 9 9 kW CO emission 13 O2 0 08 0 06 Flue gas temperature 240 0 C 314 0 C Operating mode I...

Page 3: ...ctly on a combustible floor if the floor is covered with a plate made of metal or or other non combustible material The recommended minimum thickness is 0 9 mm The whole floor inside the surround must...

Page 4: ...have a certain flexibility in order to prevent movement in the installation leading to cracks N B A correct and sealed connection is very important for the proper functioning of the product Warning We...

Page 5: ...e adapted to the insert 3 The flue pipe bend should be assembled directly onto the insert and should be able to rotate 360o Pipe 150 mm is assembled on the inside of the smoke outlet and the 175 mm is...

Page 6: ...are the correct size The size of the logs should be Kindling Length Approx 35 40 cm Diameter 3 5 cm Amount per fire 8 10 pieces Firewood split logs Mini Maxi Recommended length 35 cm 35 kg Diameter A...

Page 7: ...mwaterandaddsomeashfrom theburnchamber Rubit over the glass and then clean the glass with clean water Dry well If it is necessary to clean the glass more thoroughly we recommend using a glass cleaner...

Page 8: ...ection 2 Pull the air chamber forward while at the same time lifting it up at the edge Edge it down and remove it through the opening in the door Be aware that the part is heavy 3 Before replacing the...

Page 9: ...ooting Poor draught Check the length of the chimney and that it complies with national laws and regulations Make sure that the minimum cross section on the chimney is large enough See also 2 0 Technic...

Page 10: ...high 340995 2 units of 103x573 1 Remove the front see relevant section on 7 0 Service 2 Attach the panels A with countersunk head screws through the 2 slits at the sides of the combustion chamber Make...

Page 11: ...83...

Page 12: ...84 B C A D A B C A G F E D B A C H A B Fig 5 750 cm 2 500 cm 2 600 cm 2 C 350 cm 2 Fig 4 Fig 2 Fig 6 Fig 3 A D B C Fig 7 A Fig 8 E C D B A Fig 9 Mini Maxi...

Page 13: ...85 A B B A A B B A Fig 11 g 10 E D C B A Fig 13 C E A B D ig 12 C B A B C D A Fig 15 ig 14...

Page 14: ...86...

Page 15: ...87...

Page 16: ...n bedriftens historie startet i 1853 Qualit t J tul AS hat ein Qualit tssicherungssystem das sich bei Entwicklung Produktion undVerkauf von fen und Kaminen nach NS EN ISO 9001 richtet Diese Qualit tsp...

Reviews: