background image

24

Operation

1.

Your GI425 gas fireplace can be operated manu-
ally using the On/Off/T-stat rocker switch or it can
be automatically controlled using an optional
wall-mounted thermostat and/or remote control
device. A separate switch is provided for the
optional forced air blower kit.
Familiarize yourself with the location and func-
tion of the controls. See figs. 29 and 30.

Gas Control - 

 Used to control the Pilot light and

gas flow from the supply line.

Regulator

 - Allows you to adjust heat output and

flame intensity.

Piezo Ignito

r - Push button pilot light ignition.

ON/OFF/ T’STAT Switch

 - Allows for manual or

thermostatic control of the burner.

Always follow the Lighting Instructions located
on the inside Back Cover of this manual.

2.

For the first several hours of operation, it is
common that you will detect some odor as the
metal and manufacturing materials cure under
heat. This condition is temporary and can be
alleviated by allowing plenty of fresh air to
circulate through the area.

3.

Condensation may develop on the glass upon
each lighting of the appliance.  This “fog” will
disappear as the glass heats.

4.

Keep the controls and the area under the appli-
ance free of debris; vacuum this area frequently.
Always keep the appliance area clear and free
from combustible materials, gasoline and other
flammable liquids.
When a vacuum is used on any service for the
fireplace, ALWAYS be sure the fireplace is com-
pletely cold.

5.

Remember, your fireplace utilizes a continuously
burning pilot flame.  Exercise caution when using
household products containing combustible
vapors.

6. CAUTION:  DO NOT OPERATE THIS APPLIANCE

WITH THE GLASS REMOVED, CRACKED OR BRO-
KEN. REPLACEMENT OF THE GLASS SHOULD BE
DONE BY A LICENSED OR QUALIFIED SERVICE
PERSON.  USE ONLY REPLACEMENT GLASS PRO-
VIDED BY YOUR AUTHORIZED JØTUL DEALER.
NEVER USE ANY SUBSTITUTE MATERIALS.

 WARNING:
OBSERVE CAUTION NEAR THE GLASS

PANEL.  THE GLASS MAY SHATTER

WHEN STRUCK BY AN OBJECT.  ALWAYS

HANDLE THE GLASS PANEL WITH CARE.

Figure 30.  GI425 Controls - Gas Valve and Regulator.

Regulator

Piezo Ignitor

Figure 29.  The pilot assembly is centered under the
log set, toward the rear.

Pilot Assembly

Gas Control

Knob

Summary of Contents for GI 425 DV Camden Classic

Page 1: ...FOLLOW YOUR GAS SUPPLIER S INSTRUCTIONS IF YOU CANNOT REACH YOUR GAS SUPPLIER CALL THE FIRE DEPARTMENT AVERTISSEMENT ASSUREZ VOUS DE BIEN SUIVRE LES IN STRUCTIONS DANS CETTE NOTICE POUR REDUIRE AU MIN...

Page 2: ...d gas technology with the warm traditional elements of cast iron With proper care and use your J tul fireplace will provide you with many years of safe dependable and satisfying service The GI 425 DV...

Page 3: ...t are packed around the fireplace firebox 2 Lift the shipping carton off of the fireplace cabinet 3 Unpack the Firebox The Logset is packaged inside the firebox Remove the Glass Panel Frame to unpack...

Page 4: ...3 1 2 High Matte Black 155323 Blue Black Enamel 155324 J tul Iron Gray 155354 Fuel Conversion Kit NG to LP 155300 Fuel Conversion Kit LP to NG 155303 Wall Thermostat 750003 Remote Control 129706 J tul...

Page 5: ...requirements are established in the National Fuel Code ANSI Z223 1 NFPA 54 In Canada the codes have been established in CAN CGA B149 Fuel Installation Code Installer l appareil selon les codes ou regl...

Page 6: ...er supply when per forming routine service on the fireplace Installation Requirements The GI425 DV Camden Gas Insert can be installed in most solid fuel burning fireplaces of either masonry constructi...

Page 7: ...eplace with a tile flue liner An acceptable fireplace cavity must have the minimum dimensions specified below Air Intake Exhaust Outlet Air Intake Exhaust Outlet Figure 1 GI 425 DV dimensions E C D A...

Page 8: ...9 in max depth 47 in 1194 mm Mantel Clearance at 3 5 in max depth 41 1 2 in 1054 mm Figure 4 Wide Surround Dimensions 48 1219mm 34 864mm Clearance Requirements The following clearances and hearth req...

Page 9: ...cast iron surround panels Hearth Requirements The J tul GI425 Camden does not require special hearth protection Combustible flooring materials may be present directly in front of the fireplace insert...

Page 10: ...tion cap Minimum no less than 10 Maximum no greater than 35 See figures 9 and 10 The minimum vent height above the roof or adjacent walls is specified by building codes As a general guide follow the G...

Page 11: ...vent cap is required to bring fresh air into the chimney flue and Air Intake flex pipe d Compress the liners so that they are hanging out of the way above the fireplace opening e Attach the Fireplace...

Page 12: ...ht From Roof ROOF SLOPE To avoid cross venting the insert always label the flex to be used for the exhaust conduit at both the top and bottom ends of the flex This ensures that the exhaust flex is ins...

Page 13: ...he liners to the ports using sheet metal screws or hose clamps No silicone or sealant is required 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 1234 12...

Page 14: ...e left side of the Control Valve See Figures 9 and 10 Secure all joints tightly using appropriate tools and sealing compounds for propane units be sure to use compounds that are propane resistant Turn...

Page 15: ...SET ON HIGH Symptoms of incorrect gas pressure include Insufficient gas pressure Small pilot flame which can result in insufficient millivolts Little variation in flame picture between HI and LO sett...

Page 16: ...with the appropriate orifice 51 for Natural gas 30 for Propane Fuel Conversion The GI425 Fireplace is designed to for use with either Natural gas or Propane It is shipped from the factory configured...

Page 17: ...BE SURE TO REMOVE THE BLACK RUBBER GASKET FROM THE VALVE Install the new variable regulator tower with the new rubber gasket Thoroughly tighten new regulator to valve body 8 Apply the Conversion Labe...

Page 18: ...N OFF T STAT switch in the T STAT position and the pilot flame must be lit Remote Control The optional J tul Remote Control can be installed on the GI425 gas fireplace Using the wire supplied with the...

Page 19: ...3 Install the Lower Rear Panel Orient the panel so that the cutout is at the bottom Engage the bottom edge between the rear wall and the firebox base See Fig 17 4 Install the Side Panels Engage the b...

Page 20: ...sition on Ceramic Base pegs as shown in fig 22 The base is already installed in the fireplace 2 Set the Right Left and Center Logs on the appropriate pegs as shown in fig 23 3 Lightly scatter the Plat...

Page 21: ...fit is attained then tighten the bolts 3 Attach the Leg panels to the Breastplates The Legs must be oriented with the Hanger Tabs on the inside edges as in the drawing above Use two M6 x 12 hex head f...

Page 22: ...e provides easy adjustment of the flame height appearance and heat output To adjust the flame between the HI and LO setting rotate the HI LO knob located in the center of the valve face Flame height w...

Page 23: ...You may find it necessary to restrict the vent to some degree to accommodate the characteristics of your individual installation Generally the taller the vent height the more likely may be the need t...

Page 24: ...h the area 3 Condensation may develop on the glass upon each lighting of the appliance This fog will disappear as the glass heats 4 Keep the controls and the area under the appli ance free of debris v...

Page 25: ...switch is in either the HI or LOW setting The blower will not operate until the sensor reaches 180 F This will take 15 20 minutes in most installa tions Conversely once the burner is off the blower w...

Page 26: ...the pilot assembly burner orifice and burner tube Glass Care Clean the glass only when necessary Wipe the surface with a clean dampened soft cloth Follow with a dry soft towel Take care not to scratch...

Page 27: ...esive as you go Press the adhesive side down onto the glass surface Do not stretch the gasket 2 Place the gasketed glass within the frame and press each of the retainer clips back into place on the re...

Page 28: ...J tul GI 425 DV Camden Classic lllustrated Parts Breakdown 29 a b c d 32 37 38 33 34 36 35 39 21 14 31 30 21 27 25 16 4 5 6 7 17 76 76 76 9 17 77 77 76 45 48 49 50 51 52 54 55 57 58 59 60 61 62 63 64...

Page 29: ...Logset 4 pcs 155318 24a Rear Log 220509 24b Left Log 220510 24c Right Log 220511 24d Center Log 220512 25 Insert Base 22007292 26 Firebox 22007692 27 Air Intake Manifold 129618 28 Exhaust Baffle 2200...

Page 30: ...________________________________________ SERVICE LOG Third Year Name of Technician________________________ Company Name____________________________ Date of service_____________________________ Work Pe...

Page 31: ...e floor because some gas is heavier than air and will settle to the floor WHAT TO DO IF YOU SMELL GAS Extinguish any open flame Open windows Do not light any appliance Do not touch any electrical swit...

Page 32: ...e installation it is important that the these instructions be carefully read and understood J tul maintains a policy of continual product development Consequently products may differ in specification...

Reviews: