Jøtul GF 370 DV MV Installation And Operation Instruction Manual Download Page 28

28

130102- 1   GF 370 DV MV   2/22

42

No.  Part Number  Description

117874 

Bolt, Hex Hd M8 x 16 Ser Flange, Blk

99115 

Bolt, Hex Hd M8 x 12 Ser Flange, Blk

10447092 

Top Plate, Matte Black Paint

10431992 

Pedestal Base, Matte Black Paint

10448892 

Pedestal Side, Matte Black Paint

10453692 

Access Cover, Matte Black Paint

118019 

Bolt, Hex Hd Serr Flange M6 x 25 Blk

117947 

Washer, Flat M6 -.062 DIN 125A Plain

117968 

Nut, M6 Serrated Flange plain

10 

117976 

Screw, Flat Head Phillips M6 X 12 M/S Blk

11 

9906 

Bolt, Hex Cap, M6x30, DIN 933, Class 8.8, Blk

12 

117978 

Screw, Button Head Socket M6 x 10 Blk

14 

120004 

Washer,Fender M6 DIN 9021B Zinc

15 

222664 

Protection Cap, M8 Hex, Black

16 

222729 

Door Handle, Plated, GF 370

17 

22299592 

Top Grill, GF 370, MB

18 

222998 

Bracket, Firebox Mount, GF 370

19 

222999 

Bracket, Side Support, GF 370

20  22320792 

Bracket, Door Catch, GF 370, Matte Black

21 

156843 

Lower Door Hinge Asy. GF 370, MB

22 

156835 

Replacement Outer Side Glass, GF 370

25 

223220 

Plate, Centering, GF 370

Figure 11.2.  

External parts 

identification

27 

22558492 

Hinge, Door, MB

28 

223236 

Label, Caution, 

29 

99625 

Bolt, Hex Head Serr Flange M6x16 8.8 Blk

30  226632 

Bracket, Magnetic Catch, GF 370/373

31 

156837 

Replacement Outer Side Glass Clip Ass’y.

32 

22328592 

Bracket, Handle, MB

33 

10446392 

Door, Matte Black Paint 

34  10446492 

Side Plate, Left, Matte Black Paint

35 

10446592 

Side Plate, Right, Matte Black Paint

36 

118055 

Kepnut, M4, Ext. Tooth Lockwasher, Stl, Zinc 

37 

22383292 

Rear Cover, MB

38 

224201 

Gas Line Retainer

39 

118236 

Screw, M6 x 20

40  22385292 

Rear Seam Molding, Matte Black Paint 

 

223852WHP  Rear Seam Molding, White Paint

41 

157765 

Front Safety Barrier Screen

42 

157766 

Side Safety Barrier Screen

43  226313 

Side Plate Mounting Bracket, Left

44  226314 

Side Plate Mounting Bracket, Right

45  225338 

Magnet, .375” Dia x .25”, Neo High Temp

46  224909 

Cap, Silicone, .375” ID x .250” DP

No.  Part Number  Description

42

41

Summary of Contents for GF 370 DV MV

Page 1: ...ll be installed in the same room as the appliance WARNING If the information in these instructions is not followed exactly a fire or explosion may result causing property damage personal injury or los...

Page 2: ...rvice External regulator for Propane only Piping that complies with local code Manual shut off valve T Handle valve may be required in Massachusetts Sediment trap if required by code Tee joint Pipe wr...

Page 3: ...9 12 Lighting Instructions 31 Unpacking the Stove 1 Before beginning the installation inspect the stove for shipping damage and immediately report any evidence of damage to your dealer 2 Confirm stove...

Page 4: ...th America Gorham Maine USA J tul AS Fredrikstad Norway Test Standards This appliance complies with National Safety standards and is tested and listed by Intertek Testing Services of Middleton Wiscons...

Page 5: ...cal codes This appliance is only for use with the type s of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certified kit is used 4 The installati...

Page 6: ...appliance Clothing or other flammable materials should not be placed on or near the fireplace Never allow anyone to use the fireplace if they are unfamiliar with its operation NEVER store or use gaso...

Page 7: ...S Comply with CSA Z240 4 Gas Equipped Recreational Vehicles and Mobile Housing in Canada 3 Always contact your local officials about installation restrictions and requirements in your area THIS APPLI...

Page 8: ...imney components supplied by the following manufacturers M G DuraVent Inc Direct Vent Pro Series P O Box 1510 Vacaville CA 95696 1510 800 835 4429 Selkirk Corporation 1301 W President George Bush Hwy...

Page 9: ...entsuppliers A maximum of two 90 or four 45 elbows may be used in a vertical termination Whenever possible use 45 elbows instead of 90 elbows as they offer less restriction to the flow of flue gases a...

Page 10: ...0 square hole is adequate for proper pipe clearance through a wall provided the vent is positioned to maintain 2 minimum clearance at the top A 1 minimum clearance must be maintained to combustible ma...

Page 11: ...onmechanical air supply inlet to building or the combustion air inlet to any other appliance 12 in 30 cm 9 in 23 cm K Clearance to a mechanical air supply inlet 6 ft 1 83 m 3 ft 91 cm above if within...

Page 12: ...adjustments 3 Tighten the locking screw and replace the Trim Rings Vent Restriction Adjustments The J tul GF 370 DV MV features adjustment controls for both intake air and exhaust to accommodate a va...

Page 13: ...these offer less restriction to the flow of flue gases and intake air Reduce the overall horizontal run by 5 feet for each additional 45 and 90 elbow When two or more elbows are used in a horizontal...

Page 14: ...MASSACHUSETTS The stove and gas control valve must be disconnected from the gas supply piping during any pressure testing of the system at test pressures in excess of 1 2 psig For pressures lower tha...

Page 15: ...g 7 3 Gauge connections are identified by E for inlet or supply pressure the amount of gas com ing to the valve A for manifold pressure the amount of gas that is com ing out of the valve to the burner...

Page 16: ...nd wrench or deep well socket to remove the burner orifice from the brass orifice holder Replace with the orifice supplied in the kit CAUTION Do NOT over tighten the Burner Injector Over tightening ca...

Page 17: ...dentificationlabelstothestovesothattheycanbeseen byanypersonthatmaybeservicingthestove Label A Applytofrontlipofthevalvecompartment Label B Apply to the Rating Plate Small valve sticker Apply to valve...

Page 18: ...d on pages 21 22 Figure 7 8 High Altitude Conversion Label This appliance has been converted for use at an altitude of___________ Orifice Size __________ Manifold Press _______ Input Btu Hr _________...

Page 19: ...pilot ignition See figs 7 16 and 10 3 for examples StarFire Glass Embers Do not use more than the four pounds in two 2 lb bags of glass media provided For best results evenly spread the contents of th...

Page 20: ...Lean the Right Log up against the upper right corner of the firebox and engage the slot on the tip with the pin on the Bottom Log Figure 7 16 Evenly disperse the Ember Stones over the burner plate ar...

Page 21: ...bottom of Rear Log 2 with the two steel pins B at the left rear corner of the burner plate 5 Engage the two holes in the bottom of the Center Log 3 with the two burner plate pins C 6 Engage the holes...

Page 22: ...monia based glass cleaner 2 Hold the glass frame to firebox front with holes in align ment where socket head screws were removed 3 Replace the socket head screws into glass frame finger tight Readjust...

Page 23: ...oting in the Ceramic Burner Guide if greater than 4 seconds Reinstall the glass frame prior to hot start testing C Hot Start After the burner has been on for 5 10 minutes turn it off and wait 2 minute...

Page 24: ...source for the thermostat At the thermostat the two wires should be connected to the two connection screws on the thermostat base plate per the manufacturer s instructions CAUTION LABEL ALL WIRES PRIO...

Page 25: ...and the area under the appliance free of dust Always keep the appliance area clear and free from combustible materials gasoline and other flammable liquids 4 This appliance is operated with a continu...

Page 26: ...e assembly upside down on a flat surface protecting the frame from scratches using a blanket or towel 3 The glass panel is held in place by four retainer tabs Use a screwdriver to carefully pry these...

Page 27: ...er GF 370 MB 38 225402 Outer Rod Exhaust Restrictor 39 223224 Skamol Rear Panel 40 223235 Skamol Side Panel 2 not illustrated No Part Number Description 1 9911 Bolt Hex Cap M6x45 DIN 933 Class 8 8 Blk...

Page 28: ...or Catch GF 370 Matte Black 21 156843 Lower Door Hinge Asy GF 370 MB 22 156835 Replacement Outer Side Glass GF 370 25 223220 Plate Centering GF 370 Figure 11 2 External parts identification 27 2255849...

Page 29: ...29 130102 1 GF 370 DV MV 2 22 Figure 11 3 GF 370 DV MV Spud assembly parts identification...

Page 30: ...lock 25 117922 Nut Hex M4 DIN 934 Plain 26 3902576 Igniter Bracket 27 3902573 Piezo Ignitor Button 28 117920 Screw Pan Head Phillips M4 X 8 29 224799 Switch Plate GF 373 30 225631 Valve Bracket GF 373...

Page 31: ...31 130102 1 GF 370 DV MV 2 22 This Page is intentionally left blank...

Page 32: ...32 130102 1 GF 370 DV MV 2 22 This Page is intentionally left blank...

Page 33: ...ge due to incorrect installations not in conformance with the installation instructions contained in this owner s manual or local and or national fire and building regulations 3 Damage due to service...

Page 34: ...________________________ PHONE ____________________________________ INSTALLER __________________________________ FUEL TYPE ____________________________________ FUEL CONVERSION NO _______ YES_____ NOTE...

Page 35: ...INSTRUCTIONS WARNING IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE PERSONAL INJURY OR LOSS OF LIFE A This appliance has a pilot which must be l...

Page 36: ...s appliance must be installed in conformance with local and national building regulations Before beginning the installation it is important that the these instructions be carefully read and understood...

Reviews: