Jøtul GF 370 DV MV Installation And Operation Instruction Manual Download Page 24

24

130102- 1   GF 370 DV MV   2/22

Optional Wall Thermostat or 

Remote Control

Use only a 750 millivolt DC two-wire circuit thermostat 

with this appliance. The thermostat should be placed 

in the same room as the heater, typically 5 feet off the 

floor. Avoid drafty areas or any area that may affect the 

accuracy of the thermostat. 

The thermostat should be connected using a 

minimum of 16 gauge wire with a maximum length of 25 

feet of wire.

Connect the two thermostat wire leads to the two 

lower terminals on the terminal block located directly 

above the ignitor button.  Do not overtighten the 

connections.  

IT IS NOT NECESSARY TO DISCONNECT ANY 

OTHER WIRES.

 See Fig. 31.

For thermostatic operation, the On/Off/T-Stat switch 

on front of the valve must be in the T-stat position, and 

the pilot light must be running, as it is the power source 

for the thermostat.

At the thermostat, the two wires should be 

connected to the two connection screws on the 

thermostat base plate per the manufacturer’s 

instructions.

CAUTION:

LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING 

THE CONTROLS.  WIRING ERRORS CAN CAUSE IMPROPER OR 

DANGEROUS OPERATION.  ALWAYS VERIFY PROPER OPERATION 

AFTER SERVICING THE APPLIANCE. 

Figure 7.17.  Accessory wiring diagram.

CRITICAL  NOTE:  

THE RED THERMOPILE WIRE MUST BE CONNECTED TO THE 

VALVE TH/TP TERMINAL TO POWER THE THERMOSTAT.

Figure 7.18.  Remote receiver location

Remote Control

A remote receiver should be wired to the terminal 

block the same way the thermostat would be. 

See the instructions above. Follow the operating 

instructions included with the Remote Control unit.
Push remote receiver through left side hole of 

pedestal mounting bracket, then push forward so 

it rests on the pedestal. Run the wires around the 

back of the valve. Plug the quick connects into the 

terminal block on the right

Figure 7.19.  Remote receiver wire connection location.

Summary of Contents for GF 370 DV MV

Page 1: ...ll be installed in the same room as the appliance WARNING If the information in these instructions is not followed exactly a fire or explosion may result causing property damage personal injury or los...

Page 2: ...rvice External regulator for Propane only Piping that complies with local code Manual shut off valve T Handle valve may be required in Massachusetts Sediment trap if required by code Tee joint Pipe wr...

Page 3: ...9 12 Lighting Instructions 31 Unpacking the Stove 1 Before beginning the installation inspect the stove for shipping damage and immediately report any evidence of damage to your dealer 2 Confirm stove...

Page 4: ...th America Gorham Maine USA J tul AS Fredrikstad Norway Test Standards This appliance complies with National Safety standards and is tested and listed by Intertek Testing Services of Middleton Wiscons...

Page 5: ...cal codes This appliance is only for use with the type s of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certified kit is used 4 The installati...

Page 6: ...appliance Clothing or other flammable materials should not be placed on or near the fireplace Never allow anyone to use the fireplace if they are unfamiliar with its operation NEVER store or use gaso...

Page 7: ...S Comply with CSA Z240 4 Gas Equipped Recreational Vehicles and Mobile Housing in Canada 3 Always contact your local officials about installation restrictions and requirements in your area THIS APPLI...

Page 8: ...imney components supplied by the following manufacturers M G DuraVent Inc Direct Vent Pro Series P O Box 1510 Vacaville CA 95696 1510 800 835 4429 Selkirk Corporation 1301 W President George Bush Hwy...

Page 9: ...entsuppliers A maximum of two 90 or four 45 elbows may be used in a vertical termination Whenever possible use 45 elbows instead of 90 elbows as they offer less restriction to the flow of flue gases a...

Page 10: ...0 square hole is adequate for proper pipe clearance through a wall provided the vent is positioned to maintain 2 minimum clearance at the top A 1 minimum clearance must be maintained to combustible ma...

Page 11: ...onmechanical air supply inlet to building or the combustion air inlet to any other appliance 12 in 30 cm 9 in 23 cm K Clearance to a mechanical air supply inlet 6 ft 1 83 m 3 ft 91 cm above if within...

Page 12: ...adjustments 3 Tighten the locking screw and replace the Trim Rings Vent Restriction Adjustments The J tul GF 370 DV MV features adjustment controls for both intake air and exhaust to accommodate a va...

Page 13: ...these offer less restriction to the flow of flue gases and intake air Reduce the overall horizontal run by 5 feet for each additional 45 and 90 elbow When two or more elbows are used in a horizontal...

Page 14: ...MASSACHUSETTS The stove and gas control valve must be disconnected from the gas supply piping during any pressure testing of the system at test pressures in excess of 1 2 psig For pressures lower tha...

Page 15: ...g 7 3 Gauge connections are identified by E for inlet or supply pressure the amount of gas com ing to the valve A for manifold pressure the amount of gas that is com ing out of the valve to the burner...

Page 16: ...nd wrench or deep well socket to remove the burner orifice from the brass orifice holder Replace with the orifice supplied in the kit CAUTION Do NOT over tighten the Burner Injector Over tightening ca...

Page 17: ...dentificationlabelstothestovesothattheycanbeseen byanypersonthatmaybeservicingthestove Label A Applytofrontlipofthevalvecompartment Label B Apply to the Rating Plate Small valve sticker Apply to valve...

Page 18: ...d on pages 21 22 Figure 7 8 High Altitude Conversion Label This appliance has been converted for use at an altitude of___________ Orifice Size __________ Manifold Press _______ Input Btu Hr _________...

Page 19: ...pilot ignition See figs 7 16 and 10 3 for examples StarFire Glass Embers Do not use more than the four pounds in two 2 lb bags of glass media provided For best results evenly spread the contents of th...

Page 20: ...Lean the Right Log up against the upper right corner of the firebox and engage the slot on the tip with the pin on the Bottom Log Figure 7 16 Evenly disperse the Ember Stones over the burner plate ar...

Page 21: ...bottom of Rear Log 2 with the two steel pins B at the left rear corner of the burner plate 5 Engage the two holes in the bottom of the Center Log 3 with the two burner plate pins C 6 Engage the holes...

Page 22: ...monia based glass cleaner 2 Hold the glass frame to firebox front with holes in align ment where socket head screws were removed 3 Replace the socket head screws into glass frame finger tight Readjust...

Page 23: ...oting in the Ceramic Burner Guide if greater than 4 seconds Reinstall the glass frame prior to hot start testing C Hot Start After the burner has been on for 5 10 minutes turn it off and wait 2 minute...

Page 24: ...source for the thermostat At the thermostat the two wires should be connected to the two connection screws on the thermostat base plate per the manufacturer s instructions CAUTION LABEL ALL WIRES PRIO...

Page 25: ...and the area under the appliance free of dust Always keep the appliance area clear and free from combustible materials gasoline and other flammable liquids 4 This appliance is operated with a continu...

Page 26: ...e assembly upside down on a flat surface protecting the frame from scratches using a blanket or towel 3 The glass panel is held in place by four retainer tabs Use a screwdriver to carefully pry these...

Page 27: ...er GF 370 MB 38 225402 Outer Rod Exhaust Restrictor 39 223224 Skamol Rear Panel 40 223235 Skamol Side Panel 2 not illustrated No Part Number Description 1 9911 Bolt Hex Cap M6x45 DIN 933 Class 8 8 Blk...

Page 28: ...or Catch GF 370 Matte Black 21 156843 Lower Door Hinge Asy GF 370 MB 22 156835 Replacement Outer Side Glass GF 370 25 223220 Plate Centering GF 370 Figure 11 2 External parts identification 27 2255849...

Page 29: ...29 130102 1 GF 370 DV MV 2 22 Figure 11 3 GF 370 DV MV Spud assembly parts identification...

Page 30: ...lock 25 117922 Nut Hex M4 DIN 934 Plain 26 3902576 Igniter Bracket 27 3902573 Piezo Ignitor Button 28 117920 Screw Pan Head Phillips M4 X 8 29 224799 Switch Plate GF 373 30 225631 Valve Bracket GF 373...

Page 31: ...31 130102 1 GF 370 DV MV 2 22 This Page is intentionally left blank...

Page 32: ...32 130102 1 GF 370 DV MV 2 22 This Page is intentionally left blank...

Page 33: ...ge due to incorrect installations not in conformance with the installation instructions contained in this owner s manual or local and or national fire and building regulations 3 Damage due to service...

Page 34: ...________________________ PHONE ____________________________________ INSTALLER __________________________________ FUEL TYPE ____________________________________ FUEL CONVERSION NO _______ YES_____ NOTE...

Page 35: ...INSTRUCTIONS WARNING IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE PERSONAL INJURY OR LOSS OF LIFE A This appliance has a pilot which must be l...

Page 36: ...s appliance must be installed in conformance with local and national building regulations Before beginning the installation it is important that the these instructions be carefully read and understood...

Reviews: