background image

1

Jøtul GF 

3

 CF 

2

Conventional Flue Gas Stove

Installation and

Operation Instructions

WARNING:  If the information in
these instructions is not followed
exactly, a fire or explosion may
result causing property damage,
personal injury or death.

– Do not store or use gasoline or

other flammable vapors and
liquids in the vicinity of this or any
other appliance.

– WHAT TO DO IF YOU SMELL GAS

•  Do not try to light any appliance.
•  Do not touch any electrical

switch; do not use any phone in
your building.

• Immediately call your gas supplier

from a neighbor’s phone.
Follow the gas supplier’s
instruction.

•  If you cannot reach your gas

supplier, call the fire department.

– Installation and service must be

performed by a qualified installer,
service agency or the gas supplier.

Summary of Contents for GF 3 CF 2

Page 1: ...flammable vapors and liquids in the vicinity of this or any other appliance WHATTO DO IF YOU SMELL GAS Donottrytolightanyappliance Do not touch any electrical switch do not use any phone in your buil...

Page 2: ...ompany Date Service details Annual service year 5 Sign Company Date Service details Annual service year 6 Sign Company Date Service details Annual service year 7 Sign Company Date Service details Annu...

Page 3: ...Installer Information 6 5 User Information 12 6 Troubleshooting 14 THIS OWNER S MANUAL PROVIDES INFORMATIONTOENSURESAFEINSTALLATION AND EFFICIENT DEPENDABLE OPERATION OF YOUR STOVE PLEASE READTHESE IN...

Page 4: ...Appliance Category II2H3P Gas Types NG LPG G20 1 G31 2 State of Adjustment I2H I3P Supply Pressure mbar 20 37 NominalHeatInput Nett kW 6 3 6 8 Maximum Gas Consumption at Full Rate m3 h at 15 C 1013 25...

Page 5: ...intended for use on a gas installation with a governed gas supply SafetyPrecautions This appliance must be installed in accordance with the rules in force Consult instructions before installation and...

Page 6: ...staller When the TTB is exchanged only original manufacturer s parts shall be used Installation Guide for Qualified Personnel Important The appliance is factory pre set for Natural Gas G20 If Propane...

Page 7: ...arent reason especially during windy or stormy conditions and will not relight it is possible that the flue system safety switch has operated Allow the appliance to cool down and relight Any obstructi...

Page 8: ...pliance will not work correctly and may cut out repeatedly if the sealing of the appliance and flue is not correct Remember if the closure plate extends beyond the sides or top of the stove a non comb...

Page 9: ...tically simulate glowing coals when the burner is operating These should be spread evenly over the burner plate and around the logs 1 Engage the holes in the underside 0f the rear log with the two peg...

Page 10: ...raught diverter hood on the rear of the appli ance accessible through a cutout in the rear heatshield The smoke should be drawn into the flue and no smoke should spill into the room If the smoke does...

Page 11: ...call for service Annual Service Annual service of the appliance includes the following check points Lighting the pilot flame Cleaning the glass The gasket around the glass must be inspected annually...

Page 12: ...778 to provide extra protection Operating Instructions Lighting Note Odors when using the stove When used for the first time the appliance may emit an irritating gas that may smell a little The gas is...

Page 13: ...off of paint and lubrication used in the production process See section Odors when using the stove for the first time Adjusting the Heat Setting Heat and flame size can be adjusted by turning the reg...

Page 14: ...when the valve is being replaced Troubleshooting When No Spark is Generated at the Pilot Head It is uncommon for the Piezo spark ignitor fig 23 A to fail unless it has mechanical damage If the spark...

Page 15: ...valve even if the pressure is OK at outlet E You should therefore always check for leakage Thermocouple Fig 24 and Thermopile Fig 25 A thermocouple is in principle a thermal generator and consists of...

Page 16: ...at the back of the appliance It should be set to the ON position 2 Make sure the wire from the valve to the ON OFF STAT switch is connected correctly This is the trouble shooting procedure for the the...

Page 17: ...17 Figure 26 Check main burner orifice for debris blockage Burner pan is removed Burner Orifice...

Page 18: ...44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 4 7 61 62 63 5 64 65 1 66 67 68 69 70 71 72 73 74 75 76 77 78 79 6 81 82 83 84 85 86 30 89 88 80 90 35 34 24 87 91 92 93 94 ONLY USE REPLACEMENT PART...

Page 19: ...117917 68 Nut M6 Flange 2 117968 69 Exhaust Baffle 220763 70 Inner Draft Hood 220914 71 Screw 8 x 1 2 Blk 4 117917 72 Upper Draft Hood 222519 73 Draft Hood Cover Plate 222520 74 Starter Collar 5 dia...

Page 20: ...rmance with local and national building regulations Before beginning the installation it is important that the these instructions be carefully read and understood J tul maintains a policy of continual...