background image

Jøtul arbeider kontinuerlig for om mulig å forbedre sine produkter, og vi forbeholder oss retten 
til å endre spesifikasjoner, farger og utstyr uten nærmere kunngjøring. 

Jøtul bemüht sich ständig um die Verbesserung seiner Produkte, deshalb können 
Spezifikationen, Farben und Zubehör von den Abbildungen und den Beschreibungen in der 
Broschüre abweichen.

Jøtul pursue a policy of constant product development. Products supplied may therefore 
differ in specification, colour and type of accessories from those illustrated and described in 
the brochure.

Jøtul s’attache à l’amélioration constante de ses produits. Ceux livrés peuvent présenter 
quelques différences d’aspect, de couleur et d’accessoires par rapport au présent document.

Kvalitet

Jøtul AS arbeider etter et kvalitetssikringssystem basert på NS-EN ISO 9001 for utvikling, 
produksjon og salg av ildsteder. Vår kvalitetspolitikk skal gi kundene den trygghet og 
kvalitetsopplevelse som Jøtul har stått for siden bedriftens historie startet i 1853.

Qualität 

Jøtul AS hat ein Qualitätssicherungssystem, das sich bei Entwicklung, Produktion und Verkauf 
von Öfen und Kaminen nach NS-EN ISO 9001 richtet. Diese Qualitätspolitik vermittelt unseren 
Kunden ein Gefühl von Sicherheit und Qualität, für das Jøtul mit seiner langjährigen Erfahrung 
seit der Firmengründung im Jahre 1853 steht.

Quality

Jøtul AS has a quality system that conforms to NS-EN ISO 9001 for product development, 
manufacturing, and distribution of stoves and fireplaces. This policy gives our customers 
quality and safety piece of mind as a result of Jøtul’s vast experience dating back to when the 
company first started in 1853.

Qualité

Jøtul AS applique une procédure de contrôle de qualité conforme à la norme  NS-EN ISO 9001 
pour le développement, la fabrication et la distribution de sa gamme de poêles, foyers et inserts. 
Cette démarche assure à nos clients une tranquillité d’esprit sur la qualité et la sécurité, due 
à une expérience remontant à la création de la société en 1853.

Jøtul AS,

 

P.o. box 1411
N-1602 Fredrikstad, 
Norway
www.jotul.com

C

a

t.no
. 10038287-P02

Jøtul AS

, Oc
t. 2011

Summary of Contents for Cube 200 AG

Page 1: ...on P02 J tul Cube 200 400 500 530 GB Installation and Operating Instructions 3 FR Manuel d installation et d utilisation 15 ES Manual de instrucciones 27 IT Installazione e Istruzioni per l uso 39 NL...

Page 2: ...2...

Page 3: ...41 kg Weight J tul Cube 500 AL Approx 269 kg Weight J tul Cube 530 GG Approx 243 kg Weight J tul Cube 530 GL Approx 271 kg Weight J tul Cube 530 AG Approx 234 kg Weight J tul Cube 530 AL Approx 262 kg...

Page 4: ...es and regulations Hole in floor for external air 100 Access for external air Semi insulated chimney covered flue pipe down towards the product Min distance to combustible wall 900112 P00 1253 1178 78...

Page 5: ...le wall Firewall Min distance to combustible wall protected by approved firewall External firewall Min distance to combustible wall protected by approved firewall Integrated firewall 920 30 30 30 30 3...

Page 6: ...ced within 1 metre of the fireplace Allow the fire to burn out Never extinguish the flames with water The fireplace becomes hot when lit and may cause burns if touched Only remove ash when the firepla...

Page 7: ...e damage to the product when you unpack it and make sure that the control handles move freely The burn chamber is heavy make sure it does not topple over while you are installing it Ensure you have he...

Page 8: ...eristics and thepanel may explode at the high temperatures it is exposed to Fig 4 Overview of nuts and bolts used during mounting of the product M6 M5 x 6 DIN 7982 M5 x 16 M6 x 16 M8 x 10 4 1 Mounting...

Page 9: ...Fig 8 1 is level by adjusting the screws Fig 8 2 Fig 9 1 m a b 1 Assemble the air intake cover Optional cat no 50043352 with 4 screws Fig 9 1 Fig 10 1 2 m a b 1 Assemble the first level sides and bac...

Page 10: ...r the insert manual for instructions 2 Lift the insert Fig 12 1 on to the 3 legs Fig 12 2 Fig 13 2 1 m a b 1 Mount the first level front Fig 13 1 2 Assemble the second level sides and back Fig 13 2 an...

Page 11: ...en the product has to be placed further away from the wall Fig 18 J tul I 200 FL J tul I 500 FL J tul I 530 FL J tul I 400 FL 1 3 4 2 m a b 1 Mount the bracket Fig 18 2 between the sides and the screw...

Page 12: ...Mounting the side decor Glass decor Fig 20 m a b Lava decor Fig 21 2 1 m a b 1 Lava decor for sides consists of 10 elements Start mounting at the bottom 2 If aluminium decor Fig 23 24 Mount air grid...

Page 13: ...t the panels in the order shown in the illustration Aluminium decor Fig 23 1 3 2 4 m a b 1 Mount the panels in the order shown in the illustration 2 Join the panels and air grid together with screws F...

Page 14: ...se installation of the fireplace The buyer is entitled to return the goods provided that the fireplace has been installed in compliance with current laws and regulations and in compliance with J tul s...

Page 15: ...J tul Cube 530 GL Env 271 kg Poids J tul Cube 530 AG Env 234 kg Poids J tul Cube 530 AL Env 262 kg Hauteur avec d cor verre 1178 mm Hauteur avec d cor aluminium 1182 mm Profondeur avec d cor verre 485...

Page 16: ...ur Trous dans le sol pour air ext rieur 100mm de raccords Air ext rieur Avec chemin e semi isol e conduit de fum e isol compl tement appuy contre le produit Espace minimum par rapport un mur combustib...

Page 17: ...17 FRANCAIS Fig 1b J tul Cube 200 400 500 530 900112 P00 Mur en mat riau combustible Mur ininflammable Externe Int gr 920 30 30 30 30 30 30 30 30 1120 300 300 1150 1150 1150 1150 1050 1050 1050 1250...

Page 18: ...feu avec de l eau Le po le devient chaud lorsqu il est allum et peut provoquer des br lures la personne qui le touche Attendez que le po le soit froid pour retirer les cendres Les cendres pouvant enco...

Page 19: ...que le produit ne pr sente aucun dommage visible et que les poign es de commande se d placent librement L insert est lourd Veillez ce qu il ne risque pas de se renverser durant l installation Pr voye...

Page 20: ...es caract ristiques et le panneau peut clater lorsqu il est des temp ratures lev es Fig 4 Vue d ensemble des crous et des boulons utilis s pendant le montage du produit M6 M5 x 6 DIN 7982 M5 x 16 M6 x...

Page 21: ...en r glant l aide des vis Fig 8 2 Fig 9 1 m a b 1 Montez le couvercle de l arriv e d air en option no de cat 50043352 avec 4 vis Fig 9 1 Fig 10 1 2 m a b 1 Montez le premier niveau d l ments lat raux...

Page 22: ...pour les instructions 2 Soulevez et positionnez l insert Fig 12 1 sur les 3 pieds Fig 12 2 Fig 13 2 1 m a b 1 Montez le premier niveau avant Fig 13 1 2 Montez le second niveau d l ments lat raux et ar...

Page 23: ...it tre plac plus loin du mur Fig 18 J tul I 200 FL J tul I 500 FL J tul I 530 FL J tul I 400 FL 1 3 4 2 m a b 1 Montez le support Fig 18 2 entre les c t s et les vis de la cloche fum es Fig 18 4 et de...

Page 24: ...D cor en verre Fig 20 m a b D cor finition lave Fig 21 2 1 m a b 1 Le d cor finition lave pour les c t s se compose de 10 l ments Commencez le montage par le bas 2 Avec un d cor aluminium Fig 23 24 m...

Page 25: ...z les panneaux dans l ordre indiqu dans l illustration D cor aluminium Fig 23 1 3 2 4 m a b 1 Montez les panneaux dans l ordre indiqu dans l illustration 2 Assemblez les panneaux et la grille d air av...

Page 26: ...n droit de retourner la marchandise condition que le po le ait t install en conformit avec les lois et r glements en vigueur ainsi qu avec les instructions d installation et d utilisation de J tul La...

Page 27: ...J tul har st tt for siden bedriftens historie startet i 1853 Qualit t J tul AS hat ein Qualit tssicherungssystem das sich bei Entwicklung Produktion undVerkauf von fen und Kaminen nach NS EN ISO 9001...