NRA Biometric Holster – Rev. 00 10.14.14
Page
4
Orange LED – Program Setup Mode (Master User only)
Red LED – Primary Awaken Mode
Green LED – Scanning Mode
White button – Program Button and Wake Up Button
When determining a Master User program finger, select a finger that has
the best definition and fingerprint ridges to be a master program finger.
Other fingers can be programmed later. Light, smooth or finger prints
lacking good definition may be more difficult read and not recommended
for Master User program finger. A thumb may work better due to size of
finger and surface to read.
Biometric Control Unit can ONLY be reset back to factory settings
by Master User finger or sent back to Jotto Gear. Circle chosen
master program finger on manual and keep safe for future reference.
Forgetting which finger is the Master User will prevent ability to
program new users or erasing users in future.
Troubleshooting Programming Tips:
An ORANGE LED means the biometrics reader is prompting for the Master User scan.
During initial setup, if biometrics remains ORANGE after programming. The scanner did not get a good
read during one or more attempts. Start over from the beginning of Master User setup.
At the end of programming any sequences, if biometric control unit beeps and flashes RED LED’s and
ORANGE LED’s multiple times the user may need to start over.
If the biometric unit will not open locks by Master User during a programming attempt, resetting batteries
may be necessary.
Inserting Batteries
Remove all four top screws on biometrics
control unit.
Insert six “AA” Lithium Ion Batteries Only.
Once batteries are inserted, a Master User
fingerprint will need to be present to program for
first time. Biometric control unit will continue to
cycle power and beep until Master is
programmed.
Attach top of control unit to base with four
previously removed screws.
Low Battery Warning
The biometric control unit will intermittently check if batteries are low. An alert signal will sound with four
beeps every 15 minutes, until batteries are replaced. Only “AA” Lithium Ion batteries should be used.
Recommended battery replacement is every 6 months.
Programming Biometrics