EPIRB ERROR MESSAGES
If the self-test detects a fault in the EPIRB module one or more of the following indications are shown:
1.
Flashing LED for 15 sec. followed by one (1) flash, no Xenon flash:
Error: Low power on 406 MHz transmitter
2.
Flashing LED for 15 sec. followed by two (2) flashes, no Xenon flash:
Error: Low battery voltage
3.
Flashing LED for 15 sec. followed by three (3) flashes, no Xenon flash:
Error: Low power on 121.5 MHz transmitter
4.
Flashing LED for 15 sec. followed by four- (4) flash, no Xenon flash:
Error: PLL on 406 Transmitter out of lock
5.
Five (5) flashes, no Xenon flash:
Error: EPIRB module not programmed or programming not complete